48NDM

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9445-A  Rev.10  P. 4 / 8

75 (2.95)

103 (4.06)

10 (.39)

18

(.71)

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16

16–M3 SCREW

TERMINALS

2–M3 SCREWS

144 (5.67)

137.5 (5.41)

*

1

(.16)

36 (1.42)

31 (1.22)

100 (3.94)

Rounded corners for the option /D

 

OPTION /D BEZEL

*

3

*

1. Space required when replacing the scale plate.

*

2. Used for the existing panel cutout of M-System 48 Series (38 ×

 

139.5 mm).

*

3. Used for the existing DIN panel cutout (33 × 138 mm)

*

4. Used for the existing panel cutout of Fuji Electric PAJ, PAK, PBA (44 ×

 

138 mm), etc.

 

STANDARD BEZEL

*

2

10.4
(.41)

7.5
(.30)

3.9

(.15)

136.5 (5.37)

144 (5.67)

11.4
(.45)

7.5
(.30)

4.9
(.19)

136.5 (5.37)

144 (5.67)

8.5

(.33)

10.4

(.41)

7.5

(.30)

136.5 (5.37)

144 (5.67)

 

OPTION /F BEZEL

*

4

 

CONNECTION DIAGRAM

12

13

14

15

16

12

13

14

15

16

LLa

11

La

LLb

Lc, LLc

• DC Powered

■ 

Relay Protection

• AC Powered

7

8

9

8

9

10

HHa

7

Hc, HHc

HHb

Ha

HH OUTPUT

H OUTPUT

LL OUTPUT

L OUTPUT

■ 

ALARM OUTPUT CODE 2: 2 points

15

16

■ 

ALARM OUTPUT CODE 0: None

■ 

ALARM OUTPUT CODE 4: 4 points

+

4

3

3

2

1

POTENTIOMETER

max.

min.

2

+

4

3

3

2

1

POTENTIOMETER

max.

min.

2

+

4

3

3

2

1

POTENTIOMETER

max.

min.

2

U(+)

V(–)

La

Lb

Lc

Hc

Ha

Hb

H OUTPUT

L OUTPUT

POWER

U(+)

V(–)

POWER

U(+)

V(–)

POWER

LOAD

Inductive

Load (Coil)

Varistor or Spark

Quenching Circuit

U

LOAD

Inductive

Load (Coil)

Diode, Varistor or

CR Circuit

Summary of Contents for 48NDM

Page 1: ...f fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE or UKCA requirements in regard to the whole system and employ additional protective...

Page 2: ...TERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel cutou...

Page 3: ...d below the unit for ventilation Bracket TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 75 2...

Page 4: ...BEZEL 2 10 4 41 7 5 30 3 9 15 136 5 5 37 144 5 67 11 4 45 7 5 30 4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM 12 13 14 15 16 12 13 14 15 16...

Page 5: ...lor code 2 orange green green red red red H L 50 40 30 20 10 0 10 20 30 40 50 m3 h mA 100 SET H S P Z L 90 80 70 60 50 40 30 20 10 0 SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Dec...

Page 6: ...elay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjus...

Page 7: ...ched to continuous ON state 4 Press UP or DOWN buttons until the bargraph shows 100 and the digital indicator comes to a desired value and press SET DIGITAL INDICATOR SPAN ADJUSTMENT 1 Hold down M for...

Page 8: ...r calibration adjust the output as explained in the following HOW TO CALIBRATE THE OUTPUT INDICATION Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on...

Reviews: