background image

                                                                           

Mechanical Combination Lock 

 

                                                           

M-LOCKS BV

 

 

Tel: +31 (0)314 376 876 

Vlijtstraat 40  

ver. 1.2  2017 12 11 

Fax: +31 (0)314 376 878 

NL-7005 BN Doetinchem 

www.m-locks.com

 

 
 

Delivered Factory Code is: 4xL to 50.  

 
 
 
4x 

Turn LEFT and pass “50” three times and stop exactly  

                         

on “50” under the opening index the fourth time. 

 
Due to installation tolerances it is possible that the code may have shifted up to two 
numbers up or down.   
Also due to these tolerances it is important to re-set the code after installation.

   

 

 
With door open, turn the bolt work and lock to locked position. 
 
Dial the code at which the lock opened, on the CHANGING INDEX. 
Example: If the lock opens at “49. 
4 x LEFT until “49” stops exactly at the Changing Index 

 

1.  Carefully insert change key on the inside of the safe door. 

(Slightly wiggle if necessary.)

 

 

2.  Turn change key as shown clockwise to the stop

 (approx. 90 deg.)

 

 
 
 
 
 
 
 
 
 

Never apply excessive force 

        If change key cannot be inserted or  turned, the correct code has not been dialed to the 
        Changing Index on the dial. Take out the key and dial the valid code again 

 

Now dial your new code using the CHANGING INDEX, f.e. 10-20-30.

 

(see user instructions of the lock) 

(The last number may not be between 0 and 20) 

 

4 x

 

Turn LEFT, pass first code number “10”  three times and stop exactly on the 
number on the 

Changing

 

Index

 the fourth time. 

 

 

3 x

 

Turn RIGHT, pass second code number “20” twice and stop exactly on the 
number on the 

Changing Index

 the third time. 

 

2 x

 

Turn LEFT, pass third code number “30” once and stop exactly on the number on 
the 

Changing Index

 the second time. 

 

When turning the dial, if a number is passed, start over at the beginning. 
 
After the new code is completely entered,

 turn change key LEFT and remove it.

  The new code is 

installed. 
 

Try the new code several times (using Opening Index) before closing the door! 

 

 

 
Change Keys 

 
If installers use the 
same change key to 
set up several locks, it 
is important to inspect 
the change key regular 
basis.    
 
If the change key is 
bend or shows signs of 
wear it needs to be 
replaced.  Otherwise 
the new code will not 
be set exactly as 
dialed. 

 

 

 

 

Summary of Contents for ML6740

Page 1: ...TERISTICS The ML 6740 is a manipulation proof 3 wheel combination lock with new features making it very easy to mount VdS Kl 2 EN1300 Class B ECB S CNPP IMP DNV The lock has the standard foot print 66...

Page 2: ...t move the cam part with square hole or the bolt During installation the bolt must stay in retracted position and the cam lined up as shown left Only use the delivered 3 mounting screws 3x M6 with US...

Page 3: ...which the lock opened on the CHANGING INDEX Example If the lock opens at 49 4 x LEFT until 49 stops exactly at the Changing Index 1 Carefully insert change key on the inside of the safe door Slightly...

Page 4: ...pening manually Locking manually Blocking element 3 Wheels Mounting dimensions standard Certifications VdS Class 2 EN1300 ECB S CNPP A2P Class B UL Group 2M DNV 158 2 Listed IMP Klasa B What if accide...

Page 5: ...security lock when the safe is open Par example by a with a screws fixed interior cover The lock housing must be protected against destructive attacks from outside with suitable protective materials...

Page 6: ...S 2A spindle groove on 44 Assemble the ring so that the opening symbol is perpendicular above Cut spindle to length so that the spindle end levels with the cam Don t let spindle stick out Twist dial h...

Page 7: ...e correct code has not been dialed to the Changing Index on the dial Take out the key and dial the valid code again Now dial your new code using the CHANGING INDEX f e 10 20 30 see user instructions o...

Page 8: ...ECB S CNPP A2P Class B What if accidentally the cam got moved before installation As long as the code has not been changed with the change key the lock can be prepared for mounting following the step...

Reviews: