M Design RD 1000 Instructions For Installation And Use Manual Download Page 4

4

 

 

 

1.2.1.1 

Optimal operation 

 

Optimal  use  of  fuel  and  optimal  operation  of  the  stove  reach  loading  cca.3,5kg  of  the  wood  per  hour 

(3pieces cca.50cm long), lying horizontal on the raft in the middle of the combustion room. The chimney effect 
12-15Pa and the regulator supply air open 30%. 

 

1.2.2

 

Forbidden fuel 

The use of treated wood /painted, etc./ and all types of household waste, which can disperse hazardous 

gases,  is  FORBIDDEN  and  CANCELS  OUT  ANY  CLAIM  ON  THE  GUARANTEE.  The  use  of  fluid  fuel 
/petrol, etc. / is also FORBIDDEN. 

 

1.3

 

STARTING THE FIRE 

 

Regulation at maximum /see Pic.5/ 

 

Open the door /Pic.4 /. 

 

Put  a bed  of  tinder  (paper  or  firelighters)  with  a little  kindling  (small  twigs  or  pieces  of  wood)  in  the 
stove and light the tinder. Let the door a little open /+3cm/, so as chimney effect arose, which helps the 
kindling start the fire. 

 

After the kindling has caught fire and burns well, the logs maybe placed on the fire. When the logs are 
burning, the door can be closed. 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

NOTE: When a fire is made for the first time, the paint will harden and that give off smoke and a smell, 
which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes. See to it that 
there is ample ventilation in the room. The combustion chamber should be kept closed except for fuelling 
to prevent entry of gases into the room.  

CAUTION: 
It is not necessary to overload the fireplace with wood. 1kg dried wood gices a 4kW power. 
Example:  a fireplace  with  80%  return  gives  a power  for  about  3,2kW  for  1kg  dry  wood.  If  you  want 
a power about 6-7kW, it is just enough to put 2kg wood in the fireplace. This is like two normal pieces of 
wood.  We  are  not  responsible  for  the  wrong  use  of  fireplace  and  any  consequence  for  not  following this 
guideline. External surfaces of the stove are hot during operation, which has to be paid due attention to 
avoid an accident burns.  

2

 

INSTALLATION 

2.1

 

 INSTALLATION 

For  your  own  safety  and  satisfaction,  we  advise  you  to  entrust  specialist  with  the  installation. 

The 

appliance has to be installed according to certain prescribes rules and local regulations.

 The device must be 

built in an area with an adequate capacity, on the board, which can spread the weight of the device. The device 

max 

min 

Pic.5 

Summary of Contents for RD 1000

Page 1: ...1 COLLECTION RD 750 1000 INSTRUCTION FOR INSTALLATION AND USE ...

Page 2: ...ES TYPE RD FROM FLAMMABLE MATERIALS LOCATION OF THE STOVE SMOKE PIPES 5 2 4 LOCATION THE FIREPLACE STOVE TYPE SERIES RD ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATION THE FIREPLACE MODEL SERIES RD ON THE PLACE OF USE 6 2 7 LOCATION FIREPLACE STOVE 6 2 8 ISOLATION AND SURROUND 6 2 9 VENTILATION 6 2 9 1 Natural convection 6 2 9 2 Hot air distribution 7 2 10 CHIMNEY 7 3...

Page 3: ... screw cover back with screw 1 and 2 Pic 2 For security reasons the door is locked from both left and right site Before installation of the stove please check lifting door lifting up down and opening see Pic 4 1 2 FUEL 1 2 1 Recommended fuel Wood hard soft damp cca 16 The quality of the wood is extremely important for the optimal function of the stove output clear glass etc The ideal is to use dri...

Page 4: ...e paint will harden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room The combustion chamber should be kept closed except for fuelling to prevent entry of gases into the room CAUTION It is not necessary to overload the fireplace with wood 1kg dried wood gices a 4kW pow...

Page 5: ... series RD may not be from combustible materials respectively should be used for good thermal insulation Combustion pipe must be fitted to the fireplace chimney s mouthpiece furnace type series RD so that it is firmly and tightly connected The combustion pipe might be of black respectively stainless steel pipes and elbows The flue connection must be made by the shortest route to the flue by STN 73...

Page 6: ... CM AIR INLET OPEN ALSO FOR EXTERNAL AIR INLET IS LOCATED AT THE BACK SIDE DOWN OF THE FIREPLACE STOVE SEE PIC 6 Setting up the high of fireplace insert can be in two ways 1 to do a special higher floor or to use steel construction 2 soft setting with a set screw M16 cca 50mm see Pic 1 2 8 ISOLATION AND SURROUND FOLLOW THESE INSTRUCTIONS IF YOU DO NOT FOLLOW THE INSTRUCTIONS QUIPMENT MAY OVERHEAT ...

Page 7: ...at register We recommend that you use the design grill M design which have many advantages Pic 7 8 NOTE The circulation of hot air is required to be in the room because of the reason to do not produce any vacuum Grill under close to the floor inlet cold air Pic 8 Do not connect it through a tube Air itself will find a way to get to the right place If possible mount all the accessories using the sa...

Page 8: ...ameter 200 mm Some chimneys may require different standard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert LUNA HC can connect from the top Pic 9 3 CONTROL REGULATION Regulation of inlet of air for fireplace RD is controlled by regulation on the front bar see pic 10 by using of key as you can see bellow P...

Page 9: ...egal requirement but it also makes sense for your own safety Refractory bricks babble may still work perfectly even if they are cracked However if there are missing pieces of bricks material bricks must be replaced in order to effectively protect the combustion chamber To remove the ash residue use the ash holder see Pic 12 4 1 1 CLEANING GLASS Close the door see Pic 4 Unlock the door Pic 13 move ...

Page 10: ...stove type series RD During operating the fireplace stove type series RD is forbidden give the hand into the flow of heated air because of the security reasons there is too high temperature Fire in the fireplace stove type series RD never extinguishes with water The space where it is located fireplace stove type series RD must be ensured with adequate air inlet for combustion of fuel Loading doors...

Page 11: ... serial number see Pic 15 TYPE fireplace stove RD RD 750 RD 1000 Rated thermal power kW 14 7 15 7 Average efficiency 82 82 Heat flow into the space kW 14 7 15 7 Power range kW 4 2 15 5 2 16 Flue gas temperature at rated output C 176 2 176 2 Avg CO concentration at 13 O2 0 1 0 1 The average volume concentration of CO at 13 O2 mg m 3 1219 1219 Minimum blast Pa 12 12 The weight of the fireplace furna...

Page 12: ...885 705 1327 5 1362 5 453 4 2 6 0 933 508 562 1091 750 RD ...

Page 13: ...1135 705 1327 5 562 1220 63 1183 4 2 6 0 210 508 1362 5 1341 453 1000 RD ...

Page 14: ...ructions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the appliance without our consent In cases where the buyer cannot show his her warranty card with the purchase invoice Likewise where the guarantee and or the invoice show s signs of tampering or forgery cros sed out date legible modi...

Reviews: