11. STARTPILOT

The M-Design Gas appliance are provided with “Constant startpilot”. After the first use or when 

the winterperiod is coming and

you use the fireplace daily, you must let the startpilot switch ON. Don’t switch it off after each use. 

This startpilot avoids condensation in the fireplace and protects the whole appliance and even the 

electronic parts against humidity. 

This startpilot has a very low gasconsumption.

12. USING THE MANUAL CONTROL ( BLACK BOX )

On the user interface, a potentiometer is connected. This one will be used only when

the remote control is broken. 

DON’T USE THE POTENTIOMETER SIMULTANIOUSLY WITH THE REMOTE CONTROL 

TO SET THE REQUIRED LOAD.

When no ignition with remote control, set potentiometer knob “off” ( turn left ).

Push once on the black push button. You will hear the starpilot ignition.

Once you see the flame on the starpilot , just turn the potentiometer to the right to regulate

the flames.

To switch off , turn the potentiometer to the left “off” and push once to extinguish the starpilot 

flame. Push a second time to swith off the whole fireplace.

push button

LED

potentiometer  

knob

Summary of Contents for LUNA1300 RD GOLD GAS

Page 1: ...1 LUNA 1000 1300 RD GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 06 2012...

Page 2: ...I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I...

Page 3: ...3 Electrical connection 7 4 INSTALLING THE CHIMNEY 8 11 5 INSULATION AND FINISHING 12 6 CONVECTION CURRENT 13 14 15 7 MOUNTING A 3 SIDED FRAME 16 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEB...

Page 4: ...RD GOLD GAS 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE CLEANING THE WIN DOW IS THE ONLY MAINTENANCE ACTION THAT...

Page 5: ...der specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local regulatio...

Page 6: ...t of the fireplace by turning the bolt pic 1 A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is sit...

Page 7: ...3 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes from...

Page 8: ...300 RD GOLD GAS 8 PIC 1 ROOF EXIT C31 150 100 after elbow 90 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m 75 1300 RD 3 m 10m 75 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m 7...

Page 9: ...OLD GAS 9 PIC 2 ROOF EXIT VIA EXISTING CHIMNEY C91 It is obligatory to use the sanitation set USSAN with placing 200 min 130 Appliance C min C max Restriction HR as from 2 m 1000 RD 2 m 10m 75 1300 RD...

Page 10: ...l exit wall exit 75 A MIN 1m B 255 elbow min 90 3 DO NOT USE A REDUCTION 200 130 to 150 100 IN THIS CASE IMPORTANT BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION pic 5 IN DIRE...

Page 11: ...ntal lenght you will need to place a reduction ring of 75 Appliance 150 100 and 200 130 1000 RD 1300 RD for each 90 bend substract 1 m horizontaly or add 1 m verticaly 1000 RD 1300 RD for each 45 30 1...

Page 12: ...check the tightness of the gas pipe and the smoke pipe Once you have checked everything you can perform the final insula ting and finishing operations The built in part of the furnace tends to be ver...

Page 13: ...ds give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more quickly N...

Page 14: ...S 14 Design Grid outlet with 2 connections OUTLET CONVECTION INLET CONVECTION OUTLET CONVECTION Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm Desi...

Page 15: ...THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE EVERY OPENING YOU MAKE MUST BE...

Page 16: ...an upper and 2 sideframes see pic 2 Before mounting the 3 sided frame remove 4 sided frame lower piece by lift it carefully up Pull out the upper frame and in second way the left and right sideframes...

Page 17: ...ed down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white...

Page 18: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 18 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1000 RD GAS...

Page 19: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 19 LUNA 1000 RD GAS...

Page 20: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 20 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 LUNA 1300 RD GAS...

Page 21: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 21 LUNA 1300 RD GAS...

Page 22: ...or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a qualified tech...

Page 23: ...on 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken DON T USE THE POTENTIOMETER SIMULTANIOUSLY WITH...

Page 24: ...C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h Injector burner 6x0 85 6x0 85 6x0 6...

Page 25: ...C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar Consumption m 3 h Injector burner 6x1 1 6x1 1 6x0 65 6x0 65 6x0 65 6x0 65 Injector startpilo...

Page 26: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 26 LUNA 1000 RD GOLD gas connection gas on the back side...

Page 27: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 27 LUNA 1300 RD GOLD gas connection gas on the left side...

Page 28: ...luding the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warranty card with...