M Design LUNA1300 RD GOLD GAS Instructions For Installation And Use Manual Download Page 12

INSTRUCTION FOR INSTALLATION AND USE - LUNA 1000-1300 RD  GOLD - GAS

12

See page 37,38 and 39 for further

information about installation

pic. 1

pic. 2

pic. 3

REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE

A very essential point when setting up the Luna Gold is that the distance has to be respected inbet

-

ween fireplace and the finishing material for the mantlepiece such as marble, gipsum,...

For this, a small bended metal sheet that is provided ont the fireplace ( pic.1 ) , is to be used as the 

minimal reference for the distance. The finishing can only ga oas far as this meteal sheet ( pic.2 ). 

Don’t remove this ( pic.3 ) ! This allows you to take out the 4th side frame and to let the airflow in 

the mantelpiece for natural convection.

5.

 

INSULATION AND FINISHING

Once installation is complete, the appliance can be fitted. Before doing so, check the tightness of the 

gas pipe one more time. Light the appliance and check that it is working: check the tightness of the 

gas pipe and the smoke pipe. Once you have checked everything, you can perform the final insula

-

ting and finishing operations.

The built-in part of the furnace tends to be very warm. Please check that the furnace is not too nar-

rowly fitted and that there is adequate space for the elimination of hot air. For insulation of the 

furnace, we advise you to use M Design insulating plates. You are advised against using any other 

insulation product. Inflammable materials as well may not be used for the finishing.

min. 5 mm

Please , follow this instruction. The appliance can overheat if you not apply those instructions. 

Errorcode F02 will appear !

The masonry must be raised around the furnace. Because of the expansion of the furnace 

during combustion, an interstice of at least 5 mm must be provided on frontside and 4cm on 

each side of the appliance. The masonry must not lean against the furnace.

THE APPLIANCE MUST BE SET FREE .

Please pay attention to leave approx. 2 mm inbetween the finishing frame and maconry 

( see p.17 , mounting a 3-sided frame, and see page 37,38 and 39 for further information about 

installation

Summary of Contents for LUNA1300 RD GOLD GAS

Page 1: ...1 LUNA 1000 1300 RD GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 06 2012...

Page 2: ...I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I...

Page 3: ...3 Electrical connection 7 4 INSTALLING THE CHIMNEY 8 11 5 INSULATION AND FINISHING 12 6 CONVECTION CURRENT 13 14 15 7 MOUNTING A 3 SIDED FRAME 16 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEB...

Page 4: ...RD GOLD GAS 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE CLEANING THE WIN DOW IS THE ONLY MAINTENANCE ACTION THAT...

Page 5: ...der specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local regulatio...

Page 6: ...t of the fireplace by turning the bolt pic 1 A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is sit...

Page 7: ...3 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes from...

Page 8: ...300 RD GOLD GAS 8 PIC 1 ROOF EXIT C31 150 100 after elbow 90 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m 75 1300 RD 3 m 10m 75 200 130 Appliance C min C max Restriction 1000 RD 2 m 10m 7...

Page 9: ...OLD GAS 9 PIC 2 ROOF EXIT VIA EXISTING CHIMNEY C91 It is obligatory to use the sanitation set USSAN with placing 200 min 130 Appliance C min C max Restriction HR as from 2 m 1000 RD 2 m 10m 75 1300 RD...

Page 10: ...l exit wall exit 75 A MIN 1m B 255 elbow min 90 3 DO NOT USE A REDUCTION 200 130 to 150 100 IN THIS CASE IMPORTANT BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION pic 5 IN DIRE...

Page 11: ...ntal lenght you will need to place a reduction ring of 75 Appliance 150 100 and 200 130 1000 RD 1300 RD for each 90 bend substract 1 m horizontaly or add 1 m verticaly 1000 RD 1300 RD for each 45 30 1...

Page 12: ...check the tightness of the gas pipe and the smoke pipe Once you have checked everything you can perform the final insula ting and finishing operations The built in part of the furnace tends to be ver...

Page 13: ...ds give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more quickly N...

Page 14: ...S 14 Design Grid outlet with 2 connections OUTLET CONVECTION INLET CONVECTION OUTLET CONVECTION Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm Desi...

Page 15: ...THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE EVERY OPENING YOU MAKE MUST BE...

Page 16: ...an upper and 2 sideframes see pic 2 Before mounting the 3 sided frame remove 4 sided frame lower piece by lift it carefully up Pull out the upper frame and in second way the left and right sideframes...

Page 17: ...ed down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white...

Page 18: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 18 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1000 RD GAS...

Page 19: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 19 LUNA 1000 RD GAS...

Page 20: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 20 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 LUNA 1300 RD GAS...

Page 21: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 21 LUNA 1300 RD GAS...

Page 22: ...or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a qualified tech...

Page 23: ...on 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken DON T USE THE POTENTIOMETER SIMULTANIOUSLY WITH...

Page 24: ...C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h Injector burner 6x0 85 6x0 85 6x0 6...

Page 25: ...C 11 C 31 C 91 C 11 C 31 C 91 C 11 C 31 C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar Consumption m 3 h Injector burner 6x1 1 6x1 1 6x0 65 6x0 65 6x0 65 6x0 65 Injector startpilo...

Page 26: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 26 LUNA 1000 RD GOLD gas connection gas on the back side...

Page 27: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1300 RD GOLD GAS 27 LUNA 1300 RD GOLD gas connection gas on the left side...

Page 28: ...luding the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warranty card with...