2.5 AIR SUPPLY FOR COMBUSTION

Every form of combustion uses air. In the case of a thermally sealed room supplementary air supply 

is essential. One must at all times avoid creating under-pressure in the room. If a cooking hood ap

-

pears to be absolutely essential in the adjoining room, sufficient 

air supply will have to be provided to avoid every form of under-pressure.

You need an airlet with dia. 150mm coming from outisde, or a ventilated shelter. This airinlet you 

have to connect to the Luna.

 

 

For a double sided LUNA and the LUNA 1000V+ and 1150V+ ,

 

 

you need two air inlets dia. 150mm.

With the Luna Gold+, the fresh air for combustion is supplied directly from outside through a 

flexible ( dia. 150mm ) that is connected to one of the 4 entrances that are provided on the left, 

right or lower side of the fireplace ( pic. 4 & 5 ) . Use for this purpose one of five connection 

pieces ( pic. 6 & 7 )

Thanks to this new system, the air that is required for combustion is completely separated from 

the convection air stream in the room ( see further at point 2.3. Convection current ). 

The appliance is always delivered with an open air inleet at the left side. If you want to change, 

you can remove the plate on the side you wish to connect en replace the plate on the side that was 

open before.

pic. 5 

pic. 4 

pic. 6 

pic. 7 

    FRESH AIR INLETS FROM OUTSIDE 

    NEEDED FOR COMBUSTION

 

ø

150

Luna Gold 700 H+       

1 x 

ø

150

Luna Gold 850 H+ 

1 x 

ø

150

Luna Gold 1000 H+

1 x 

ø

150

Luna Gold 1150 H+ 

1 x 

ø

150

Luna Gold 1300 H+

1 x 

ø

150

Luna Gold 550 V+

1 x 

ø

150

Luna Gold 850 V+

1 x 

ø

150

Luna Gold 1000 V+

2 x 

ø

150

Luna Gold 1150 V+

2 x 

ø

150

Luna Gold 1150 DH+

2 x 

ø

150

Luna Gold 1000 DV+

2 x 

ø

150

Luna Gold 850 DH+

2 x 

ø

150

Luna Gold 850 DV+

2 x 

ø

150

Summary of Contents for LUNA GOLD+ COLLECTION

Page 1: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD LUNA GOLD COLLECTION INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 08 2011...

Page 2: ...N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W O R K I N G A...

Page 3: ...2 6 2 Convection generated by a fan optional 2 6 3 Hot air ducts 2 7 FAN 12 2 7 1 Installation 2 7 2 Fan dimmer 2 8 FLUE 13 2 8 1 Flue 2 9 HOW TO REGULATE FIREPLACE IN SENSE OF DROUGHT 14 2 9 1 Baffl...

Page 4: ...he stove output clear glass etc Good quality wood is wood that has been dried under an aerated shelter for at least 2 years 18 moisture content Damp wood gives off less heat and dirties the stove and...

Page 5: ...rden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room CAUTION It is...

Page 6: ...s and conditions of our contract of guarantee Ask your supplier for advice pic 1 pic 2 pic 3 A min 3 5 cm B 14 5 cm C min 18 cm 2 2 POSITIONING THE FIREPLACE Place the fireplace on a stable surface us...

Page 7: ...ing you can perform the final insulating and finishing operations The built in part of the furnace tends to be very warm Please check that the furnace is not too narrowly fitted and that there is adeq...

Page 8: ...ATTENTION TO LEAVE APPROX 2 MM INBETWEEN THE FRAME AND THE FINISHING MATERIAL HEAT EXPANSION pic 1 pic 2 pic 3 8 Example Finished size of the Luna 1150H Gold is 450 x 1080 mm Thickness 3 sided frame...

Page 9: ...cted to one of the 4 entrances that are provided on the left right or lower side of the fireplace pic 4 5 Use for this purpose one of five connection pieces pic 6 7 Thanks to this new system the air t...

Page 10: ...a fan optional It is compulsory to open at least 2 hot air vents see table 1 It is essential to separate the air supply ducts and the air vents correctly in the masonry Some insulation material gets...

Page 11: ...D WOOD EACH APPERTURE YOU MAKE MUST BE CONNECTED WITH FLEXIBLE Design Grid outlet with 2 connections Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4 dm...

Page 12: ...at some grids give off more heat than others and seeing that a hot air pipe func tions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even mo...

Page 13: ...lue and its position are very important One individual flue does not have more than two changes of direction The angle of the corner of these changes of direction may not be greater than 45 with the p...

Page 14: ...ught The baffle plate is automatically opened when the window is slid open so that no smoke escapes into the living room The plate may be adjusted in 2 ways 2 9 1 1 FIRST SETTING ANGLE BAFFLE PLATE WI...

Page 15: ...screws to adjust the moving plate nr 1 fig 9e in sence of drough FIG 9e IMPORTANT IF YOU THINK THE DROUGHT IS NOT ENOUGH AND YOU HAVE SOME SMOKE RETURN IN THE LIVINGROOM THEN YOU HAVE TO CHECK FIRST P...

Page 16: ...nto the livingroom Fig 10 door closed Fig 11 door open 2cm valve on second deflector main valve Installing the deflectors The first deflector 1 exists of two parts A movable part 1a and a fix part 1b...

Page 17: ...window is regulated automatically with two bimetallic strips At each of the superior corners of the window you ll find two circular magnets Those ensures that the window is closing well against the b...

Page 18: ...open with the result that the fire will keep burning much more mildly When there is a fire with two lift doors open both the plates will automatically open up completely and therefore there will be n...

Page 19: ...ir coming into the fireplace Pic 9 When the door is opened the air clapet is also being opened Extra air is going in the fire place trough apertures situated in the 4th side frame direct from the air...

Page 20: ...ve your chimney swept at least once a year for optimal functioning of the Luna Not only is this a legal requirement but it is also meant for your own safety A fire brick Chamotte can still work perfec...

Page 21: ...lfunctions linked to Incorrect installation of incorrect connection Chimney draught that has not been adjusted Transport and installation Incorrect usage Insufficient maintenance Unsuitable hazardous...

Page 22: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 6 SPARE PARTS...

Page 23: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 7 3 SIDED FRAME...

Page 24: ...INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD WOOD 8 4th sided Frame...

Reviews: