M Design Luna Diamond 1000 RD Instructions For Installation And Use Manual Download Page 5

5

INSTRUCTIONS FOR INSTALLATION AND USE 1000-1300RD GAS

3. Installing the fireplace

After having checked the appliance, you are ready to install your appliance. This is 

done as follows

3.1.1 Positioning the appliance

Place the appliance on a stable surface using the adjustable feet. Adjust the height of 
the appliance turning the bolt.

                         

The appliance must not be placed directly on the floor as you need to allow 
natural convection. The appertures for the air supply (IN) is situated under-
neath the appliances. Minimum distance to floor = 35mm

Minimum and Maximum hight of the appliance :

Adjusting the height of the appliance Min 35mm to 450mm (floor to under the appliance). 

If you want the fireplace to be installed with a different height, unscrew the nut to remove the feet.
Grind the desired height on foot. The distance between two holes is 40mm. With the fireplace is provided 4 
small saucers. Use to get the stud under your feet.
If you want to install the fireplace at the minimum height of 35mm, measured from the floor to
Below the firebox: remove the foot and unscrew the nut below the foot. Aim the nut in
The tarred hole that is located below the hearth in the corner. Do the same for the four feet.
The minimum distance from the floor to the bottom of the frame is 244 mm.

Summary of Contents for Luna Diamond 1000 RD

Page 1: ...V12 2019 Luna Diamond 1000 RD 1300 RD CLOSED GASFIREPLACES INSTRUCTIONS FOR INSTALLATION AND USE Distributor Manufacturer M Design Benelux BVBA B 8210 Zedelgem Belgium ...

Page 2: ...S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N MAINTENANCE GAS FIREPLACE M DESIGN THE M DESIGN GAS FIREPLACES MUST BE CHECKED EVERY 2 YEARS AND GET A MAINTENANCE THIS IS ALSO TO MAINTAIN YOUR WARRANTY IF THIS WILL BE NOT OBSERVED THE WARRANTY FELL YOU CAN RELY ON M DESIGN TO MAKE THIS CHECK FOR YO...

Page 3: ... Gas connection 8 3 1 4 Electrical connection 9 3 1 5 Modification natural gaz to propane 9 4 INSTALLING THE CHIMNEY 10 13 5 FLAME ADJUSTMENT SETTINGS 13 14 6 INSULATION AND FINISHING 14 7 CONVECTION CURRENT 15 17 8 POSITIONING THE LOGS 17 19 9 FIRST TIME USE 20 10 SAFETY ADVICE AND MAINTENANCE 20 11 GUARANTEE 21 12 SPECIFICATIONS 22 23 13 REMOTE CONTROL 24 25 14 DESIGN GRIDS 26 15 DRAWINGS 27 ...

Page 4: ...tion that may be performed on the device by the user Thanks to a patented system the door can be easily opened at an angle of 45 to allow a user friendly cleaning of the window To close push the door gently but not to soft against the hooks Make sure that all hooks are hooked CLOSING OPEN Above the glass below the upper frame hooks are provided left right and center Push it upwards with your finge...

Page 5: ...5mm Minimum and Maximum hight of the appliance Adjusting the height of the appliance Min 35mm to 450mm floor to under the appliance If you want the fireplace to be installed with a different height unscrew the nut to remove the feet Grind the desired height on foot The distance between two holes is 40mm With the fireplace is provided 4 small saucers Use to get the stud under your feet If you want ...

Page 6: ...iever DFGT 03MC01 V09 Transmitter burner S4965C3029 Gas valva VK4105ME5004 to main burner Dimensions gasunit L365 xB188 x H64mm For safety reasons The gasbattery or NEARBOX is fixed with screws on the pallet Unscrew and remove the gasunit before installation 3 1 2 Nearbox gasunit ...

Page 7: ...ided with a direct ignition no starting pilot 3 1 3 The Gas connection Valve 1 2 After the NEARBOX has removed from the of the back of the fire you can place it loosely on the ground in proximity to the opening provided in the wall of mantelpiece The device is always con nected with an approved gas tap 1 2 and preferably with a yellow gasflexible that is reachable at all times Provide the mantelpi...

Page 8: ...n earthened 220V socket necessary You should bear in mind that the appliance must be connected to all electrical supplies for the purposes of service It s obligatory to connect an earth current 3 1 5 Modification natural gaz to propane Modification of the fireplace can only be done by the manufacturer or an approved installer A new signal plate is provided ...

Page 9: ...indicated by ONTOP METALOTERM The only authorised pipes are ONTOP Metaloterm ONTOP METALOTERM tested our appliances with their conduct and we only guarantee a good working of the appliance with those Between the external wall of the pipe and the wall or the ceiling you should allow for a clearance of at least 50mm and protection that is suitable against temperatures of around 130 C The passage of ...

Page 10: ...000 1300RD GAS Ø200 min Ø 130 Appliance C min C max 1000 RD 2 m 10m 1300 RD 2 m 10m USDVC13 4 2 ROOF EXIT VIA EXISTING CHIMNEY C91S flex 130mm This USSAN piece must be sealed at the roof This USSAN piece must be sealed at the top of the chemney ...

Page 11: ... RD 1m Wall exit Wall exit A B A IMPORTANT Be carefull every horizontal part does not have a negative in clination in direction of the outlet It is even better when possible to have a little inclination of 2 or 3 degrees ascending to avoid rain and condenstation in the tube Install wall outlet like fig 1 4 3 WALL EXIT C11 ...

Page 12: ...n B max C min A B C max 1000 RD 1 m A C B A 12m 1300 RD 1 m A C 1 B A 1 10m A B C A B C Appliance Ø 200 130 1000 1300 RD for each 90 bend subtract 1m horizontally or add 1m vertically 1000 1300 RD for each 45 30 15 bend subtract 0 5m horizontally or add 0 5 m vertically Picture 4 ROOF EXIT WITH BEND ...

Page 13: ...is blue it can mean that there is too much air in the combustion chamber but also that there is too little air If there is too much air the flame move very quickly Attention burner have to burn continuously evenly in the whole length included secondary burners By adjusting the flame cannot remove up from burner cannot be separated flame from burner it is really dangerous Then there is too little a...

Page 14: ...ed M Design has developed hot air and ambient air outlet grilles available from your dealer Outlet grids have two or four hose connections 2 4 hoses on 1 grid The air inlet grilles not to be connected with a hose must be placed as low as possible at the bottom of the fireplace Please follow this instructions The appliance can overheat if you not apply those instructions Errorcode F02 will appear A...

Page 15: ...ll Inlet Grill Inlet Inlet Outlet EXIT CONVECTION You can choose between 3 models of grids according to your taste or according to the fireplace Grid Design 2 connections Grille design long small model 2 connections or long model 4 connections AIR ARRIVAL ENTRY CONVECTION You have the option to choose between inlets 2dm3 or 4dm3 7 1 CONVECTION GRILLS ...

Page 16: ...MM see pic below This will avoid the heating of the electronic part of the appliance In this case you will have errorcode F02 CONVECTION INLET ATTENTION if the installer opens the openings in advance these must be covered during the work grinding drilling sawing etc Dust released during installation will otherwise sneak into convection circuit Dust can never be eliminated properly and give off a l...

Page 17: ...e window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use other products Other decorative products are prohibited in our appliances Please do not change the...

Page 18: ...18 INSTRUCTIONS FOR INSTALLATION AND USE 1000 1300RD GAS Logs for Luna Diamond 1000 RD Gas ...

Page 19: ...19 INSTRUCTIONS FOR INSTALLATION AND USE 1000 1300RD GAS Logs for Luna Diamond 1300 RD Gas ...

Page 20: ... Safety device and maintenance Have your appliance inspected every 2 years by a qualified technician Please observe the following points Closed appliances produce intense heat which means that all the surfaces of the external walls metal door frames and windows become very hot once a certain tempera ture is reached Make sure that young children do not touch the window this could result in severe b...

Page 21: ...ence of Non respect of the order installation and maintenance instructions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the appliance without our consent In cases where the buyer cannot show his her warranty card with the purchase invoice Likewise where the guarantee and or the invoice s...

Page 22: ... C 91 Aansluitdruk Pression d entrée mbar 25 20 30 37 50 28 30 Branderdruk Pression de brûleur mbar Verbruik Consommation m 3 h Inspuiter brander Injecteur bruleur 6 x 0 85 6 x 0 85 6 x 0 6 6 x 0 6 6 x 0 6 6 x 0 6 Inspuiter waakvlam Injecteur veilleuse 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement Rendement Nom Belasting Charge nominale KW Nuttig vermorgen Puissance utile KW Klassement NOX e...

Page 23: ...mation m 3 h 1 132 1 026 0 344 0 389 0 389 0 295 Inspuiter brander Injecteur bruleur 6 x 1 10 6 x 1 10 6 x 0 65 6 x 0 65 6 x 0 65 6 x 0 65 Inspuiter waakvlam Injecteur veilleuse 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Rendement Rendement 85 87 70 70 70 70 Nom Belasting Charge nominale KW 9 2 9 7 8 4 9 5 9 5 9 5 Nuttig vermorgen Puissance utile KW 8 0 8 4 5 9 6 7 6 7 6 7 Klassement NOX emmissie C...

Page 24: ...ing The ticking lasts for about 15 sec At initial setup it s possible that the pilot flame doesn t ignite imidiatly because the pipes are not yet fully deflated You can try this up to 5 times before the unit will be placed in safety If this fails pleas contact your installer 12 Remote control direct ingnition 3 Manual control From the moment the burner is on you can start with the flame height con...

Page 25: ...perature sensor is in the remote control To get back to manual control do the smame until and are blinking Confirm with 4 Thermostatic control each model is standard delivered with ECO WAVE ECO WAVE is an automatic cycle of fluctuating flames At each start up of the fire the system starts in ECO WAVE mode 5 ECO WAVE Symbol that indicates that WAVE is enabled Press 1x short on the menu button and 1...

Page 26: ...50 13 126 126 200 200 550 350 1223 82 64 72 268 114 44 100 225 77 102 250 180x180 200 200 Grille design sortie avec 2 raccordements Grille d arrivée d air entrée 2dm3 Grille d arrivée d air entrée 4dm3 Grille design longue petit model sortie Grille design longue grand model sortie 14 DIMENSIONS DESIGN GRILLS ...

Page 27: ...4 28 162 916 422 374 26 974 534 30 1060 263 300 Ø150 125 890 1070 Ø200 130 30 86 984 3 min 35 max 450 30 4 5 237 464 474 237 916 28 422 267 399 int 224 162 30 Ø200 130 890 min 35 max 450 26 1360 407 ext 263 220 4 5 263 300 300 1274 125 30 86 1284 1370 534 Ø150 1204 374 30 3 464 Luna Diamond Gaz 1000RD Luna Diamond Gaz 1300RD 15 DRAWINGS ...