INSTALLATIEVOORSCHRIFT EN GEBRUIKSAANWIJZING - LUNA 1000-1300-1600 H GOLD - GAS
INSRUCTION D’INSTALLATION ET D’UTILISATION - LUNA 1000 -1300-1600 H GOLD - GAZ
M-DESIGN
3
1. GENERAL REMARKS
This is a moulding of the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the
impression of a real chimney fire.
The gas with air-vent furnaces are based on the principle of natural extraction from the furnace, which eliminates flue gas outside and brings in air (oxygen) from outside
the house which is necessary for combustion of the gas. It uses to this effect two concentric pipes. The internal pipe ensures the elimination of burned gases and the ex-
ternal pipe brings in combustion air. The advantage of this principle is that the equipment works independently of the atmosphere which predominates in the house.
2. CONNECTION
This appliance must be connected by an approved installer in accordance with the most recent regulations in force. On the basis of your order specifications, this appli-
ance is designed for natural or propane gas.
Read the instructions before installing and using this appliance. Before installing the furnace, please check the local regulations about this type of furnace (identification
of the type of gas, etc.) and check that the furnace is adapted to your means of installation.
CAUTION: The furnace must be connected to the type of gas mentioned on the appliance. Never connect a propane burner to natural gas or vice versa!
It is imperative that the installer sees to the following:
•
The appliance must be subject to a water tightness test of the gas and elimination of flue gases.
•
The concentric pipe, if already available, must be working correctly.
•
The running of the control valve, lighting of the pilot light, the main burner and the thermocouple must all be checked.
This appliance has been programmed and factory sealed. The sealed parts cannot be modified. The appliance may therefore also be installed in watertight accommodation
and accommodation equipped with mechanical ventilation. It constitutes ambient heating even in accommodation equipped with a closed ventilation system.