M Design LUNA 850 V Gold Gas Instructions For Installation And Use Manual Download Page 10

INSTALLATIEVOORSCHRIFT EN GEBRUIKSAANWIJZING - LUNA 1000-1300-1600 H GOLD - GAS

INSRUCTION D’INSTALLATION ET D’UTILISATION - LUNA 1000 -1300-1600 H GOLD - GAZ

M-DESIGN 

10

9

1

2

3

4

5

6

7

8

0

INSTALLATIEVOORSCHRIFT EN GEBRUIKSAANWIJZING - LUNA 850 V GOLD - GAS

INSRUCTION D’INSTALLATION ET D’UTILISATION - LUNA 850 V GOLD - GAZ

M-DESIGN 

10

7. PUTTING IN PLACE THE LOGS, DIAMOND, SAPPHIRE AND WHITE STONES

• 

Please check that the pilot light is switched off and that the furnace has cooled down.

• 

Move the window to the front by pulling it. The window tips open at 45°. 

• 

Arrange the materials supplied. In accordance with your order you will have either a set of logs, diamond, sapphire or white pebbles. There 

is an adequate supply of materials . Our appliance is approved with these materials, so please do not use other products. Other decorative products 

are prohibited in our appliances. Please do not change the delivered quantities.

ARRANGING THE SET OF LOGS

Caution: do not put anything on the pilot light. To arrange the logs respect the order as follows.

 

 

Summary of Contents for LUNA 850 V Gold Gas

Page 1: ...LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire ...

Page 2: ...AZ M DESIGN 2 SUMMARY 1 GENERAL REMARKS 3 2 CONNECTION 3 3 SPECIFICATION SHEET 4 4 ASSEMBLY OF THE CHIMNEY 5 7 5 ELECTRICAL CONNECTION 8 6 INSULATION AND FINISHING 8 7 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEBBLES 9 8 FIRST TIME USE 10 9 SAFETY ADVICE AND MAINTENANCE 10 10 GUARANTEE 11 APPENDIX Instructions for use of the remote control ...

Page 3: ...ent regulations in force On the basis of your order specifications this appli ance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local regulations about this type of furnace identification of the type of gas etc and check that the furnace is adapted to your means of installation CAUTION The furna...

Page 4: ...31 C31S C11 C31 C31S Entry pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 23 8 19 3 29 36 36 28 2 Consumption m3 h 1 132 0 789 0 344 0 389 0 389 0 295 Burner injector Fr Re 6 x 0 80 6x0 75 6 x 0 80 6 x 0 5 6 x 0 6 6 x 0 6 6 x 0 6 6 x 0 6 Pilot light injector 38 33A 38 33A 0 20P3 0 20P3 0 20P3 0 20P3 Output 87 87 1 74 74 74 74 Nominal load KW 9 2 9 7 9 5 9 5 7 0 7 0 Output power KW 8 0 8 4...

Page 5: ... 4m LUNA 850 V 2 m 18m Ø 60 TAB 2 This is recommanded with a roof exit 3m 4 INSTALLING THE CHIMNEY The only authorised pipes are ONTOP Metaloterm Between the external wall of the pipe and the wall or the ceiling you should anticipate for an interstice of at least 50mm and protection that is suitable against temperatures of around 130 C The passage of the front panel cowl in the external wall must ...

Page 6: ...1600 H GOLD GAZ M DESIGN 6 FIG 2 Fig 2 ROOF EXIT VIA EXISTING CHIMNEY C31S AARDGAS 200 min Ø 130 Toestel Appareil C min C max Restriction HR from 3m LUNA 850 V 2 m 10m Ø 60 150 min Ø 100 Toestel Appareil C min C max Restriction HR from 4m LUNA 850 V 3 m 18m Ø 60 TAB 1 TAB 2 It is obligatory to use the sanitation set USSAN with placing ...

Page 7: ...50 100 Ø 200 130 Appliance A min B min Restriction HR B max LUNA 850 V 1 25m wall exit Ø 70 A 8m Ø 150 100 Appliance A min B min B max Restriction HR LUNA 850 V 1 25m wall exit A 0 5m Ø 75 A Ø 200 130 in combination with B Ø 150 100 Appliance A min B min B max Restriction HR LUNA 850 V 1 25m wall exit A USVK13 4m with reduction part USVK13 on the appliance with reduction part USVK13 placed horizon...

Page 8: ...1 25 m A C B A 16m with reduction part USVK13 on appliance Ø 200 130 Appliance A min B max C min A B C max LUNA 850 V 1 25 m A C 7m B A 9m 20m CAUTION if the vertical lenght is over 3 meter longer than the horizontal lenght you will need to place a reduction ring of Ø 60 Appliance Ø 150 100 and Ø 200 130 LUNA 850 V for each 90 bend substract 1 m horizontaly or add 1 m verticaly LUNA 850 V for each...

Page 9: ...ck that the furnace is not too narrowly fi ed and that there is adequate space for the elimination of hot air For insulation of the furnace we advise you to use M Design insulating plates You are advised against using any other insulation product Inflammable materials as well may not be used for the finishing The enclosure of the furnace must be provided with ventilation grills or openings allowing f...

Page 10: ...ot light is switched off and that the furnace has cooled down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use other products Other decorativ...

Page 11: ...w or with the door open If the window is broken or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 9 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a qualified technician Please observe the following points Closed appliances produce intense heat which means that all the surfaces of the external walls metal door frame...

Page 12: ...he defects which occur are fully or partially a consequence of Non respect of the order installation and maintenance instructions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warranty card with the purchase invo...

Reviews: