The fireplace type series „LUNA HC“ must be installed so that before it left space on the layout, about 1 x
1 m.
Basis respectively base under fireplace type series „LUNA HC“ must be straight fire material and must
withstand heat stress. Also, wall and ceiling material, which the fireplace type series „LUNA HC“ may not
be from combustible materials, respectively should be used for good thermal insulation
Combustion pipe must be fitted to the fireplace chimney`s mounthpiece furnace type series „LUNA HC“ so
that i tis firmly and tightly connected.
The combustion pipe might be of black respectively stainless steel pipes and elbows. The flue connection must
be made by the shortest route to the flue by STN 73 4210. The combustion pipe should be implemented and
concolidate in order to be released accidentally or spontaneously. Pipes that are plugged into each other, should
be inserted in the direction of flow of exhaust gases. Where the flue passes through building structure, which
contains flammable materials, or surface modified flammable materials should be insulated to protect the
crossing design and implement in accordance with Decree MV SR No. 95/2004 statute.
Connection the combustion pipe of the furnace type series „LUNA HC“ can only be the chimney, which has
been expertly tested. Based on expert examination of the appliance flue connection and issue a professionally
qualified person „Certificate examination on implementation of the chimney, where a professionally qualified
person to deliver state of the chimney and flue for their safe and reliable operation.
2.4
LOCATION THE FIREPLACE FURNACE TYPE SERIES „LUNA HC“ ON THE
FLOOR
In the place of installation fireplace insert type series „LUNA HC“ on the floor must be ensured a minimum
floor load 1000 kg.m
-2
. The floor before the fireplace insert type series„LUNA HC“ must be fire-resistant
material at a distance of at least 1000 mm from front wall of the fireplace isert type series „LUNA HC“.
2.5
REQUIREMENTS FOR PASSING COMBUSTION AIS
The fireplace furnace type series „LUNA HC“can be placed directly in the heated respectively outside
the heated space. The combustion of fuel used air from the area where is the fireplace furnace, or it is possible to
transport external admission of air and connect it according to the point 2.10. In case of insufficient ventilation
of this area is necessary to ensure sefficient fresh air.
2.6
INSTALLATON THE FIREPLACE MODEL SERIES „LUNA HC“ ON THE PLACE
OF USE
Fireplace type series "LUNA HC" is installed in the heated or outside of heated space.
For the location of the fireplace insert type series "LUNA HC" in the heated space, the operator must decide
whether to implement the distribution of heated air or not. If the operator decides that yes, it is necessary to
ensure the distribution of heated air from the space garnishment fireplace insert type series "LUNA HC" by flex-
tube respectively. through appropriate pipes for the heated air inlet temperature of 150 ° C to the desired
location. If the operator decides that no heated air is to be exported from the area Converted fireplace insert with
a hot air diffusers, in order to ensure air circulation.