6
2.7
LOCATION FIREPLACE FURNACE
FIREPLACE INSERT SHOULD NOT BE LAID ON THE FLOOR DUE TO THE NATURAL FLOW
OF AIR.
AIR-INTAKE OPEN IS LOCATED AT THE REAR OF FIREPLACE FURNACE./PIC. 3A/
Setting up the fireplace insert can be in two ways:
Fine-tuning using screws /pic.3b/.
Minimum height from the floor to bottom of the fireplace furnace
3,5cm .
The height from floor A=170mm
2.8
ISOLATION AND SURROUND
FOLLOW THESE INSTRUCTIONS. IF YOU DO NOT FOLLOW THE INSTRUCTIONS QUIPMENT
MAY OVERHEAT.
Once installation is omplete, the device may be doing the surround. If you check everything you can to make a
final insulating and finishing operations. Make sure the device is not put too tight and that there is adequate
space for the flow of hot air. We suggest that you use for insulation insulating plates M-Design. You are advised
to use other insulating materials. Flammable materials are also prohibited.
A very important point when installing the distance which must be between fireplaces and building materials
such as marble.../pic.4a bad version / and / pic.4b good design /.
Pic.3a
Pic.4a
min.5mm
Pic.4b
Pic.3b
A