INSTRUCTION FOR INSTALLATION AND USE - INTERRA - WOOD
2.2 CONVECTION CURRENT
The INTERRA can be ordered with or without pre-installed fan . This must be con
-
firmed when ordening.
2.2.1 Natural convection
Without fan you are not obliged to use the hot air vents.
But if above the fireplace there is a decorative wooden beam or other combustible
material you have to install Hot Air Vents.
PICTURE BELOW : CIRCULATION FLOW OF THE CONVCTION AIR.
2.2.2 Convection by means of a fan (optional)
If you opt for a fan, the fresh air will be drawn in from below of the appliance and
then blown out through the convection casing. The fan is mounted on the back of the
appliance. By removing the chamot on the back and unscrew the metal plate behind
this chamot, it’s easy to have acces to the fan.
When using a fan it is not obligatory to connect air ducts.
2.2.3 Fan ( optional )
• The fan (optional) starts automatically when à temperature of 50°C is reached, and
swithes off again automatically when 30°C is reached.
• The fan (optional) stops automatically working when the door you open the door.
This is a fully automatically working fan, wothout using a Dimmer or Speed Control
-
ler for the fan.
Convection inlet
Convection outlet
To have access to the fan, remove
the chamot on the back and remove
the screwed metal plate.
7
Connection side power supply
220V is situated at the left
side of the appliance. You can
change to the right side of the
appliance.