16
EvacSkate 14
6.4 MALFUNCTION, INSPECTION, RESOLUTION PROCEDURE
TROUBLE
CAUSE
COUNTERMEASURE
No power supplied. LED
won‘t illuminate.
Insufficient insertion of Power
Plug into outlet.
Check outlet and securely
connect Power Plug.
No power is supplied.
Check power and other relevant
parts.
Power Cord is broken.
Arrange its repair or
replacement.
Battery Charger‘s power
source trouble
Arrange a check or repair.
Receptacle and Plug are
improperly connected.
Check the connecting parts and
securely connect them.
Battery Pack is improperly
connected.
Check the connecting parts and
securely connect them.
Green LED illuminates
soon after the start of
charging.
Battery is normally
charged.
Normal.
Battery malfunction.
Replace with a new Battery.
(See P 17.)
The charging process is
completed however work
able period is shortened.
Battery nearly dead.
Replace with a new Battery.
(See P 17.)
Ambient temperature is low
during charging.
Charge Battery in an ambient
temperature between 5 and
40°C.
• For safe handling of Charger, be sure to read the instructions
thoroughly before using Charger.
• Charger is only to be used with an AC100-240V power
source. Never connect Power Cable to any other power
source specification.
• Be sure to finish trickle charging within 12 hours after battery
charging process is completed. Extended charging may
reduce battery capacity re¬sulting in shorter battery life.
• Battery and Charger‘s Output Terminals have polarity. Confirm
that those Terminals are correctly connected according their
polarity. Improper connection will result in a short circuit and
cause a cable to melt or other serious charger malfunction.
• Never remove Charger Cover or you will risk receiving an
electric shock.
• Keep Charger indoors, away from direct sunlight and water
splashes. Neglecting this can cause fire, electric shock or
equipment malfunction.
• As Battery deteriorates, its voltage will fail to reach normal
full-charge voltage.
CAUTION
CAUTION
16
CAUTION
16