Appendix B: System Exclusive Implementation
102
Venom User Guide
Arpeggiator Header Data Dump
When an Arpeggiator Edit buffer data is recalled the following data is sent as part of the SysEx:-
Parameters can also be individually updated using the appropriate address.
*** Off/On is determined by evaluating the CC value received. If the CC value is 63 or lower, the state is “Off.” If it is 64 or higher,
the state is “On.”
Global Parameters Data Dump
When a Global data is recalled the following data is sent as part of the SysEx:
Parameters can also be individually updated using the appropriate address.
Addr [H]
Parameter Name
Range
00 00
ArpPatch.Enable
Off/On ***
00 01
ArpPatch.ArpSrc_f
Off/On ***
00 02
ArpPatch.Bank
0 ~ 1
00 03
ArpPatch.Pattern
0 ~ 127
00 04
ArpData.ArpMode
0 ~ 2
00 05
ArpData.NoteOrder
0 ~ 4
00 06
ArpData.OctaveRange
-4 ~ +4
00 07
ArpData.BiPolar
Off/On ***
00 08
ArpData.LatchKeys
Off/On ***
00 09
ArpData.RootNote
0 ~ 127
00 0A
PatchName [0]
0 ~ 127
00 0B
PatchName [1]
0 ~ 127
00 0C
PatchName [2]
0 ~ 127
00 0D
PatchName [3]
0 ~ 127
00 0E
PatchName [4]
0 ~ 127
00 0F
PatchName [5]
0 ~ 127
00 10
PatchName [6]
0 ~ 127
00 11
PatchName [7]
0 ~ 127
00 12
PatchName [8]
0 ~ 127
00 13
PatchName [9]
0 ~ 127
Addr [H]
Parameter Name
Range
00 00
Octave
61-68 (-3 ~ +3)
00 01
Transpose
48-72 (-12 ~ +12)
00 02
MasterTune
14-114 (-50 ~ +50)
00 03
MasterTempo
50 ~ 300
00 04
GlobalChan
0 ~ 15
00 05
MidiOutMode
0 ~ 1
00 06
LocalMode
0 ~ 1
00 07
VelCurve
0 ~ 3
00 08
FixedVel
1 ~ 127
00 09
MidiReceiveClockMode
0 ~ 2
00 0A
MidiTransmitClockMode
0 ~ 2
00 0B
MidiSingleSel_f
Off/On ***
00 0C
MidiMultiSel_f
Off/On ***
00 0D
ArpegRoute
0 ~ 1
00 0E
SustainPedal CC
0 ~ 134
00 0F
ExpresssionPedal CC
0 ~ 131
Summary of Contents for Venom