background image

26

  

 

|

 

 

SEDONA SiDE burNEr AccESSOry cArE & uSE/iNStAllAtiON

SIDE  BURNER EXpLODED pARTS LIST

  ITEM NO.  

MODEL  

PART NUMBER  

DESCRIPTION  

QTY.

 

1  

LSB501  

N/A  

PAN / BODY WELDMENT  

1

 

 

LSB502  

N/A  

PAN / BODY WELDMENT  

1

 

2  

LSB501 

33921  

COVER  

1

 

 

LSB502  

33916 

COVER  

1

 

3  

LSB501/2  

33827  

BATTERY/TRANSFORMER MTG BRACKET 

1

 

4  

LSB501/2  

80693  

MANIFOLD WELDMENT  

1

 

5  

LSB501  

33952  

ORIFICE, N.G.  

1

 

 

LSB502  

33952  

ORIFICE, N.G.  

2

 

6  

LSB501  

33945  

ORIFICE, L.P.  

1

 

 

LSB502  

33945  

ORIFICE, L.P.  

2

 

7  

LSB501  

33946  

CAP, INNER  

1

 

 

LSB502  

33946  

CAP, INNER  

2

 

8  

LSB501  

33947  

CAP, OUTER  

1

 

 

LSB502  

33947  

CAP, OUTER  

2

 

9  

LSB501  

33948  

PORT RING, BURNER  

1

 

 

LSB502  

33948  

PORT RING, BURNER  

2

 

10  

LSB501  

33949  

BASE, BURNER 

1

 

 

LSB502  

33949  

BASE, BURNER  

2

 

11  

LSB501  

33950  

IGNITOR, BURNER  

1

 

 

LSB502  

33950  

IGNITOR, BURNER  

2

 

12  

LSB501  

33955  

WASHER, LARGE  

1

 

 

LSB502  

33955  

WASHER, LARGE  

2

 

13  

LSB501  

33340  

VALVE, SIDE BURNER W/SPRING  

1

 

 

LSB502  

33340  

VALVE, SIDE BURNER W/SPRING  

2

 

14  

LSB501  

33922  

BAR GRATE  

1

 

 

LSB502  

33866  

BAR GRATE  

1

 

15  

LSB501/2  

31162  

SPARK MODULE  

1

 

16  

LSB501  

33932  

KNOB, BURNER  

1

 

 

LSB502  

33932  

KNOB, BURNER  

2

 

17  

LSB501  

10001  

BEZEL  

1

 

 

LSB502  

10001  

BEZEL  

2

 

18  

LSB501  

31929  

SCREW, #6-32 x 1/8” LG., S/S  

2

 

 

LSB502  

31929  

SCREW, #6-32 x 1/8” LG., S/S  

4

 

19  

LSB501  

34038  

FITTING, ELBOW, VALVE TO TUBING  

1

 

 

LSB502  

34038  

FITTING, ELBOW, VALVE TO TUBING  

2

 

20  

LSB501  

34040  

TUBING, FLEX W/ COMP. FITTINGS  

1

 

 

LSB502  

34040  

TUBING, FLEX W/ COMP. FITTINGS  

2

 

21  

LSB501/2  

31930  

SCREW, 1/4-20 x 3/8” LG. HEX.  

2

 

22  

LSB501/2  

14026  

LOCK WASHER, 1/4 SPLIT  

2

 

23  

LSB501/2  

14044  

WASHER, 1-1/4” O.D., S/S  

2

 

24 

LSB501  

34039  

ADAPTER FITTING  

1

 

 

LSB502 

34039 

ADAPTER FITTING 

2

 

25  

LSB501/2  

30781  

PRESSURE REGULATOR 4/11  

1

 

----  

LSB501  

70052  

WIRE HARNESS, LED  

1

 

 

LSB502  

70053  

WIRE HARNESS, LED  

1

 

----  

LSB501  

70121  

WIRE HARNESS, IGNITION  

1

 

 

LSB502  

70067  

WIRE HARNESS, IGNITION  

1

 

---- 

 LSB501/2  

70040  

WIRE HARNESS, POWER  

1

 

---- 

 LSB501  

80694  

MANIFOLD COMPLETE ASSY.  

1

 

 

LSB502  

80695  

MANIFOLD COMPLETE ASSY.  

1

 

----  

LSB501/2  

31879  

BATTERY HOLDER ASSY WITH DIODE  

1

Summary of Contents for Sedona LSB502LP

Page 1: ...SEDONA SIDE BURNER ACCESSORY CARE USE INSTALLATION MAKE THE MOST OF YOUR...

Page 2: ...ts Silica crystalline which is used in one of the components of the IR burner as an agent known to the state of California to cause cancer If you smell gas 1 Shut off all gas supply lines to the grill...

Page 3: ...ustibles besides your food that might ignite If no clear the area before starting the lighting process If yes please con tinue Do all control knobs turn freely If not call for service if yes please co...

Page 4: ...ving installation Always have an ABC Fire Extinguisher accessible never attempt to extinguish a grease fire with water or other liquids storing your accessory Store your accessory in a well ventilated...

Page 5: ...by carefully reading this manual before your first cook out This manual includes important safety tips and great hints for better grill ing You should keep it handy for easy reference Also at Lynx we...

Page 6: ...tion must meet local electric codes or in the absence of local codes the latest edition of the National Electrical Code ANSI NFPA No 70 or the Canadian Electrical Code CGA 1 6b2005 Use only a Ground F...

Page 7: ...and can melt knobs and ignition modules Such damage is specifically excluded from your warranty 10 Never use charcoal or any other solid fuel in the grill accessory 11 Cooking excessively fatty meats...

Page 8: ...Your Run 13 Are You On the Level 13 Built in Installations 14 Clearance to Combustible Materials 14 Gas electric Connections 15 Gas Plumbing 15 Natural Gas 15 LP Gas 16 Converting for Fuel Type 16 LP...

Page 9: ...ose appliances Accessories Covered in this Manual The LSB501 and LSB502 Side Burner 1 2 feature either one or two 12 500 BTU Hr burners for cooking smaller food items The LSB501 and LSB502 are designe...

Page 10: ...Do not use any grill or side burner if you smell gas LIGHTING INSTRUCTIONS 1 Remove burner cover completely Do not attempt to light any burner with the cover in place 2 Ensure all knobs are in the OF...

Page 11: ...ent The burners on your Lynx accessory feature an adjustable low setting Fluctuations in gas pressure gas conversion and even in the quality of the gas itself may affect burner performance at the LOW...

Page 12: ...f the drip tray on the heat shield behind the front panel For warranty service contact the Lynx Customer Care Department for an authorized service agent near you at 888 289 5969 www lynxgrills com You...

Page 13: ...outdoor use only Never use in a garage building shed breezeway or other enclosed area Do not use this equipment under any overhead combustible construction Installation must conform with local codes...

Page 14: ...INDEX Electrical Connections When a grill is not available or if the grill is not located close enough to the accessory a LASK Switch Kit is avail able from the manufacturer as an optional purchase C...

Page 15: ...l installation parts must conform to local codes with the National Electrical Code ANSI NFPA 70 1990 and the National Fuel Gas Code ANSI Z223 1 NFPA 54 in the U S and CGA B149 1 2 in Canada Canadian i...

Page 16: ...ubt have it checked by your LP supplier Always check for leaks after every LP cylinder change See INDEX Leak Testing for further details Always shut off the LP gas supply at the cylinder when the acce...

Page 17: ...tremely cold temperatures may cause your burner to light inside the burner instead of outside Once lit if you hear a whooshing sound immediately turn the burner knob off to extinguish the flame and th...

Page 18: ...more details Connecting the Wiring The accessory electrical harnesses are designed to provide power for both ignition and lighting While ignition is con trolled at the accessory lighting is controlled...

Page 19: ...ith the gas flow 4 For LP turn the cylinder valve knob counter clockwise one full rotation 5 Apply the soap solution generously by paint brush or squirt bottle on all connections and fittings 6 If bub...

Page 20: ...le Female Pins MF Molex Female Male pins MM RIGHT BURNER LEFT BURNER Molex Male Female Pins LSB502 Side Burner LEAD WITH PIN DEAD LEAD NO PIN LED Light MF Molex Female Male pins Green Varistor MM Mole...

Page 21: ...SEDONA side burner accessory care use installation 21 Side Burner Connector SIDE BURNER SCHEMATICS continued...

Page 22: ...1 cm2 kg of stored fuel capacity If ventilation openings at floor level are in a side wall there shall be at least two openings The bottom of the openings shall be 1 in 25 4 mm or less from the floor...

Page 23: ...her obligations or liabilities related to the sale or use of its grill products 4 Warranty shall not apply and Lynx is not responsible for damage resulting from misuse abuse alteration of or tampering...

Page 24: ...24 SEDONA side burner accessory care use installation 1 2 3 4 7 8 9 10 11 12 13 14 15 16 17 18 23 21 22 19 20 24 25 5 6 LSB501 Side Burner SIDE BURNER EXPLODED PARTS VIEW...

Page 25: ...SEDONA side burner accessory care use installation 25 4 7 11 2 14 8 9 16 18 17 1 3 12 10 13 21 23 22 15 20 19 24 25 5 6 LSB502 Side Burner SIDE BURNER EXPLODED PARTS VIEW continued...

Page 26: ...LSB502 33340 VALVE SIDE BURNER W SPRING 2 14 LSB501 33922 BAR GRATE 1 LSB502 33866 BAR GRATE 1 15 LSB501 2 31162 SPARK MODULE 1 16 LSB501 33932 KNOB BURNER 1 LSB502 33932 KNOB BURNER 2 17 LSB501 1000...

Page 27: ...ments 15 Gas Supply Line Runs 17 Gas to LP Conversion 16 Grilling in Windy Conditions 7 L Leak testing 19 Lighting the Burner 10 Lighting with a Match 11 Locating Serial Number 12 LP Conversion 16 LP...

Page 28: ...Lynx Professional Grills 5859 Rickenbacker Rd Commerce CA 90040 Lynx Customer Care 888 289 5969 Fax 323 838 1778 www lynxgrills com...

Reviews: