SEDONA SiDE burNEr AccESSOry cArE & uSE/iNStAllAtiON
LP Gas
The side burners that are factory preset for use with LP gas
come equipped with a 4/11 regulator, Lynx part number
30781. The regulator is used for permanently plumbed,
hard piped LP connections, such as those in line with a
bulk cylinder. If connection to a Type 1, 20 lb LP cylinder
is required a LP gas pressure regulator and hose assembly
is required and must be the type specified by Lynx. (See
INDEX: “Contacting Lynx”.)
When a LP gas pressure regulator and hose is used, the
4/11 regulator must be removed to prevent over-regulation.
ConvertinG for fueL tyPe
After changing the orifices the service technician must make
sure the correct regulator setting is used. If you are using the
4/11 convertible regulator, ensure that it is set for the correct
fuel. The correct fuel type will be abbreviated at the end of
the plunger. The service technician must remove the cap and
check the plunger. If needed, pull the plunger from the cap,
flip it over and re-attach it to the cap. Then re-attach the cap
into the regulator and tighten with a 7/8 inch wrench.
Never connect an unregulated gas line to the grill accessory.
When exchanging your cylinder for a refill, exchange only
for a Type 1 20 lb. cylinder with an over-fill protection de-
vice.
Never use a cylinder with a damaged valve.
A dented or rusty LP cylinder may be hazardous and should
be avoided. If in doubt, have it checked by your LP supplier.
Always check for leaks after every LP cylinder change. (See
INDEX: “Leak Testing” for further details.)
Always shut off the LP-gas supply at the cylinder when the
accessory is not in use.
Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children. If your accessory is stored in-
doors, the LP cylinder must be stored outside.
Place a dust cap on the cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage of
propane.
Mettre un bouchon antipoussière sur la sortie du robinet
d’une bouteille qui n’est pas utilisée. Utiliser uniquement
le type de bouchon antipoussière fourni avec le robinet de
la bouteille. D’autres types de bouchons pourraient ne pas
être étanches et permettre des fuites de propane.
LP ConneCtions
Make sure the LP cylinder valve is fully closed. It is possible for
the valve to be open without releasing gas but, as soon as you
start connecting the regulator, gas will leak from the connec-
tion.
Insert the regulator inlet into the cylinder valve and turn the
black coupler clockwise until the coupler is hand tight. Do
not over-tighten this connection.
To disconnect the coupler, first make sure the main cylinder
valve is turned off. Grasp the coupler and turn counter clock-
wise. Always leak-test the connection after refilling or ex-
changing LP cylinders. (See INDEX: “Leak Testing” for further
details.)
lp cylinder with type 1 valve connection
Gas & electric connections
...