3.7.3 I/O Options – Misc
From the Lynx MAT select Setup…Configuration
Z
Modify
Z
I/O Options
Z
Misc. See Figure 3-11.
Enter the information specific to the installation for the intended certification.
Figure 3-11: Lynx MAT – I/O Options – Misc
1.
ARINC 429: Set up the ARINC Input and Output bus using the following:
a.
Input One
: None.
b.
Input Two
: None.
c.
Output One
: Select either None or CDTI. Selecting CDTI sets the ARINC 429 Output to
transmit traffic data from the unit to an approved traffic display.
2.
RS-422: Set up the RS-422 interface as follows:
a.
Baud Rate
: Select a baud rate appropriate to the equipment connected via the RS-422 bus.
b.
ADS-B Output
: This option enables or disables output of traffic on the RS-422 output bus.
Note: Must be enabled for RS-232 WiFi option.
c.
FIS-B Weather Output
: This option enables or disables output of weather on the RS-422
output bus. Note: Must be enabled for RS-232 WiFi option.
3.
CDTI Output
: This option enables or disables output of TIF or DTIF data to a CDTI ARINC 429
interface.
4.
Control Panel
: Only one choice (Touch screen) is available.
Page 3-14
Installation Checkout
0040-17001-01
January 15, 2015