Page 1: ...means cannot be locked attach a tag to the service panel to indicate power has been switched off for maintenance 3 Install this Rangehood Only with Remote Blower Models Rated Maximum 12 8A or Integra...
Page 2: ...n accordance with all requirements specified by the manufacturer G Install this hood using required clearance from cooking surface to combustible material specified by the manufacturer READ AND SAVE T...
Page 3: ...op of the hood is flush with the ceiling 4 Insert all four of the allthread bolts into the top of the hood Approximately 3 5 While lifting the hood guide and position the allthread through the 2x4s Un...
Page 4: ...ROUGH IN PLATE MOUNTED TYPICAL INSTALLATION 30 to 36 cooktop filter grease trough hood ceiling 10 round duct transition rough in plate lag screws Figure A Vertical Discharge 4...
Page 5: ...screws on the back of the unit as shown in Figure 1 3 Detach the transition from the rough in plate by removing four 4 screws The shipping screws are needed for re attaching the transition to the roug...
Page 6: ...EAL ALL JOINTS WITH DUCT TAPE STEP 2 MOUNTING THE IN HOOD FAN 1 Install the fan by aligning the holes on the fan to the weld studs on the rough in plate Tighten the fan to the plate using the hex nuts...
Page 7: ...the rough in plate hole 3 Remove the junction box from the rough in plate Connect black wire to power supply black wire white wire to power supply white wire and green wire to power supply green wire...
Page 8: ...w enough room for duct cover width on the top section of the rough in plate 2 Slide Duct Cover into opening 3 Attach Duct Cover from the inside of the hood through filter opening using the screws prov...
Page 9: ...nter of the space provided for the filters insert one filter on the top ledge and pull back until the bottom of the filter slips into bottom ledge 3 Slide the filter to one side 4 Install the next fil...
Page 10: ...ft Volumetric Flow Rate CFM Duct Dimensions 10 dia 9 dia 8 dia LOHE REMOTE FAN 261 4 203 4 10 28 14 4 17 APPLICATION Maximum CFM 1200 Electrical Motor Rating 8 0 Amps 115V AC 60 Hz Duct Size at Disch...
Page 11: ...11...
Page 12: ...f the hood INTERIOR OF HOOD All hoods are fitted with a brushed stainless steel liner For cleaning we recommend using pre washed flannel cloths and Stainless Steel cleaner Always wipe in a manner whic...
Page 13: ...r design without notice Some models are certified for use in Canada Lynx is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian d...
Page 14: ...lectrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhaustin...
Page 15: ...28 5 7 8 B C E F G I H REMOTE VENTILATOR DIMENSIONS Fig 5 A ROUND DUCT ROOF ELBOW TAPE JOINT 1 2 CONDUIT NOT INCLUDED TYPICAL INSTALLATION ELBOW ROUND DUCT TRANSITION DIRECT DUCT INSTALLATION Fig 4 TR...
Page 16: ...r installation on a flat roof or roofs with pitch less than 1 1 2 in 12 inches install LOHE on curb so that the discharge low end points away from prevailing winds 3 Install the remote fan on the roof...
Page 17: ...alls to the remote ventilator using color coded wires corresponding to color codes indicated in figure 8 4 The white plastic Molex electrical connector inside the hood feeds the power to the remote ve...
Page 18: ...5...
Page 19: ...REMOVE VENTILATION TIPS 1 Leave Appliances such as Ranges Cooktops Barbecue Units Grills etc require adequate ventilation Hood should be large enough and Cooking Appliances located so that the Hood o...