![Lynx LOH1236 Installation Instructions Manual Download Page 17](http://html1.mh-extra.com/html/lynx/loh1236/loh1236_installation-instructions-manual_1954041017.webp)
TO REMOTE VENTILATOR
POWER IN
PIG TAIL
SUPPLIED
WITH
LOHE BLOWER
FROM
HOOD
PANEL
HOOD
J BOX
Detail A
4
III. WIRING A LOHE REMOTE VENTILATOR USING THE HOOD
SPEED CONTROL
1. Power supply required for these ventilators is 15 amps. @ 120V. AC, 60Hz. connected per local codes.
2. Run three #14 AWG. wires (black, white and green) from the power supply at the electrical circuit panel
to the hood J-box. See Detail A.
3. Run five wires from hood J-box through the walls to the remote ventilator, using color coded wires
corresponding to color codes indicated in figure 8.
4. The white plastic Molex electrical connector inside the hood feeds the power to the remote ventilator.
Use the receptacle connector provided with the ventilator and plug into the connector in the hood.
Within the J-box connect the black, white, red and blue wires from the remote ventilator to the black,
white, red and blue wires of the “pigtail”. Connect the green (ground) wire to the ground wire from
the service panel.
WARNING:
Disconnect power before
installing switch.
Before turning power on,
be sure that all controls are in
the OFF position.