38
|
SEDONA CARE & USE/INSTALLATION
BTU OUTPUTS & MAXIMUM RUNS
MODEL-SPECIFIC BTU OUTPUTS
MODEL
TUBE BURNER
ROTISSERIE
PROSEAR™
TOTAL INPUT
L500PS
1 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
46,000 Btu/Hr
L500PSR
1 @ 23,000 Btu/Hr
1 @ 12,500 Btu/Hr
1 @ 23,000 Btu/Hr
58,500 Btu/Hr
L600PS
2 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
69,000 Btu/Hr
L600PSR
2 @ 23,000 Btu/Hr
1 @ 14,000 Btu/Hr
1 @ 23,000 Btu/Hr
83,000 Btu/Hr
L700PS
2 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
69,000 Btu/Hr
L700PSR
2 @ 23,000 Btu/Hr
1 @ 16,000 Btu/Hr
1 @ 23,000 Btu/Hr
85,000 Btu/Hr
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135.000
70
123,000
80
115,000
NOTE: IF A 1/2 INCH LINE IS USED
WITH NATURAL GAS IT SHOULD BE