![Lynx HR-SERIES User Manual Download Page 8](http://html1.mh-extra.com/html/lynx/hr-series/hr-series_user-manual_1954003008.webp)
LYNX Pro Audio S.L. -
Valencia, Spain -
www.lynxproaudio.com [email protected]
HR-series
3.4 Installation accessories
The HR cabinets are designed to be used in installations and the full range cabinets come with rigging points
so that they can be easily installed. To fi x the cabinets to a wall or to hold them from the ceiling is very easy
using some simple accessories:
AGR-10
Eye bolt for all the full range HR cabinets:
SC-FC1
Install stud for HR-1564/7 , HR-1596/7 , HR-1264/7 and HR-1296/7
SC-FC2
Heavy duty stud for HR-1564/7 , HR-1596/7 , HR-1264/7 and HR-1296/7
HBR-28 and HBR-26
Horizontal bracket for HR-28 or HR-26
8
NOTE: The bi-amp mode works without the internal crossover so without its protection for the speakers.
Change the cable from one plug to the other and screw the connector
pannel again. That’s all.
You will have the cabinet ready in bi-amp mode, with pin ± 1 connected
to Low Frequencies and pin ± 2 connected to High Frequencies.
1 2
3.3 Mode passive or bi-amp
All the HR cabinets are supplied from the factory in passive mode. To change from passive to bi-amp mode is
very simple, you only have to unscrew the connector pannel located at the rear of the cabinet and change the
cable from the PASSIVE plug to the ACTIVE plug. These plugs are marked on the circuit board.