Lynteck LS800S Engineering Manual Download Page 3

1.2 Tools Required 

The following tools are required for installation: 

★ 

Large & small flat bladed screwdrivers and cross point screwdrivers 

★ 

Hammer 

★ 

Power drill 

★ 

Wire cutters and wire stripper 

★ 

Eye protection (recommended when using a power drill or hammer) 

 

1.3 System Features 

★ 

Simple and effective Eight-zone system with the new patented two-wire technology. 

★ 

All system components (sensors, bellbox) are connected to the Control Unit via two-core 
non-polarity  flat  wires.  Wiring  and  installation  of  the  system  is  extremely  simple  and 
easy. 

★ 

Control  Unit  has  built-in  infrared  receiver,  with  status  LEDs  and  zone  indicators.  Panic 
and tamper attempts will be indicated by the status LEDs. 

★ 

Maximum 8 remote keys can be accepted for full arm, part arm, disarm, panic and learn 
key functions 

★ 

“Full arm” and “Part arm” modes are pre-programmed for user convenience. 

★ 

The tamper zone is indicated by both Tamper LED and Zone LED (for Zone 4 to 8). 

★ 

All  sensors,  bellbox  are  24  hour  line-protected  and  fully  supervised;  any  attempt  to 
interfere  with  the  system  will  trigger  the  alarm  and  be  identified  by  flashing  LEDs  and 
zone indicator. 

★ 

Two  PIR  motion  detectors  can  be  connected  to  one  zone,  therefore  the  system  can  be 
expanded  to  have  ten  PIR’s  plus  many  magnetic  contacts.  Also,  easy  connections  are 
provided for adding telephone dialer to the system.

 

★ 

Remote key reader is available for user convenience.

 

★ 

Optional two wire bellbox is available 

★ 

Optional normal bellbox connection terminals are provided.

 

★ 

Optional voice dialer is available to increase the security level.

 

Summary of Contents for LS800S

Page 1: ...components Section 3 Installation your system 3 1 Control Unit 3 2 Movement Detector PIR 3 3 Door Window Detector 3 4 Remote Key Reader 3 5 Bellbox 3 6 Testing the system Section 4 Using your system 4...

Page 2: ...ving person one unit may cover entire room DOOR WINDOW CONTACT Three pairs Uses a magnetically operated switch to sense the opening of door or window REMOTE KEY INFRA RED REMOTE KEY Two units They are...

Page 3: ...s LEDs Maximum 8 remote keys can be accepted for full arm part arm disarm panic and learn key functions Full arm and Part arm modes are pre programmed for user convenience The tamper zone is indicated...

Page 4: ...r to large metal objects or on metal surfaces It needs to be mounted on a wall or in a corner at a height of approximately 2 to 2 5meters for the best general coverage in an average room The detector...

Page 5: ...e back door or window and assigned to Zone 2 or 3 Having chosen the location do not mount at this stage Infra Red Remote Reader Location Choose a location near the most frequently entry exit door so t...

Page 6: ...r m Le ar n Err or Z one 1 Z one 2 Z one 3 Z one 4 Z one 5 Z one 6 Z one 8 P A Tam p er Z one 7 Zone Area 1 Front Door 2 Back Door 3 Spare 4 Living room 5 Dining room 6 Kitchen 7 Bedroom 1 8 Bedroom...

Page 7: ...tchen 7 Bedroom 1 8 Bedroom 2 BELLBO X KITCHEN HALL BEDRO O M 2 LS800S CO NTROL UNIT BEDRO O M 1 ZO NE7 ZO NE4 ZO NE8 ZO NE6 ZO NE2 ZO NE1 REM O TE KEY READER The Zone 4 PIR has been placed in the Din...

Page 8: ...ttom Illustration 1 Connect the rechargeable battery on to the control unit and fix it by the battery clips Illustration 2 Err or Lear n Par t Arm Ful l Ar m Pow er TAM P DETECTO R ZONE ZONE 2 1 ZONE...

Page 9: ...n e 1 Z o n e 2 Z o n e 3 Z o n e 4 Z o n e 5 Z o n e 6 Z o n e 8 T a m p e r Z o n e 7 TWO WIRE SYSTEM P A D C BATT 12V 12V AC BATT DC 14V CPTAM 1 CPTAM 1 CPTAM 1 VOLUM E W ALK ALARM TEST CPTAM 1 AC...

Page 10: ...opposite the PIR zone terminals are put in position 1 For connecting two pieces of PIR on the same zone Zone 8 you need to put the corresponding slide switch to position 2 For more information please...

Page 11: ...ing holes in the wall Choose one of the cable entry holes C and make a third hole in the detector base Put one end of the 2 core wire through this hole C then secure the PIR to the wall using two scre...

Page 12: ...ce two wire PIR to the zone you need to set the corresponding switch to position 1 When connecting 2 pieces two wire PIR to the same zone terminals put the corresponding switch to position 2 The wirin...

Page 13: ...itch on the frame Illustration 8 Choose a convenient entry point for the cable on the switch housing and carefully remove part of the plastic using a sharp knife to create a hole Illustration 9 Connec...

Page 14: ...move the cover retaining screw from the base of the bellbox cover Illustration 13 Take off the cover from the bellbox baseplate Use the bellbox baseplate as a template to mark and drill fixing holes I...

Page 15: ...g the push button again at any time will clear the latched LED and walk test is restarted 6 On completion of walk test close the cover of the control unit and an OK tone two rapid beeps is emitted and...

Page 16: ...D STBBELL D IAL VE TIG Power up LS800S control panel 5 rapid beeps Learn LED is flashing Day The panel is in LEARN mode Learn Only zone 1 LED is flashing indicates the first Zone 1 2 remote keys is go...

Page 17: ...on the path between control unit and exit entry zone 6 TW PIR Instant Instant Protect area when part arm is used 7 TW PIR Instant Omit Protect area for full arm only 8 TW PIR Instant Omit Protect area...

Page 18: ...d DELAY two wire PIRs but Omit zone will be inactive i e detectors in the Omit Zone 7 and 8 will be disabled e g at night with people inside house Learn LED flashing System in Learn mode and ready for...

Page 19: ...exact requirements Movement Detector Two wire PIR covers a large area easy to wire Door Window Contact Detector small robust and reliable Remote Key additional remote key for family member to operate...

Page 20: ...be Outputs 12V Aux Output 12V Infra Red Remote Key Type Battery operated infra red signal transmitter Housing ABS Operational distance Up to 12m Operational Voltage 3V Battery type CR2032 PIR Type Dua...