Lynteck LS800S Engineering Manual Download Page 1

 

 

LS800S Intruder Alarm System 

 

Engineering Manual 

 

 

Table of Contents 

Section 1 – Overview of System 

1.1 

Kit Contents 

1.2 

Tools Required 

1.3 

System Features 

Section 2 – Planning your installation 

2.1 

Location of components 

2.2 

Planning the location for the system components 

Section 3 – Installation your system 

3.1 

Control Unit 

3.2 

Movement Detector/PIR 

3.3 

Door/Window Detector 

3.4 

Remote Key Reader 

3.5 

Bellbox 

3.6 

Testing the system 

Section 4 – Using your system 

4.1 

Normal Operation 

4.2 

Learn the first remote keys 

4.3 

Select entry timer 

4.4 

Summary of the zones in different mode 

4.5 

Summary of Factory Settings 

4.6 

Status of LED indications 

Section 5 – Maintenance 

Section 6 – Extending your system 

Section 7 – Specifications 

 

 

Summary of Contents for LS800S

Page 1: ...components Section 3 Installation your system 3 1 Control Unit 3 2 Movement Detector PIR 3 3 Door Window Detector 3 4 Remote Key Reader 3 5 Bellbox 3 6 Testing the system Section 4 Using your system 4...

Page 2: ...ving person one unit may cover entire room DOOR WINDOW CONTACT Three pairs Uses a magnetically operated switch to sense the opening of door or window REMOTE KEY INFRA RED REMOTE KEY Two units They are...

Page 3: ...s LEDs Maximum 8 remote keys can be accepted for full arm part arm disarm panic and learn key functions Full arm and Part arm modes are pre programmed for user convenience The tamper zone is indicated...

Page 4: ...r to large metal objects or on metal surfaces It needs to be mounted on a wall or in a corner at a height of approximately 2 to 2 5meters for the best general coverage in an average room The detector...

Page 5: ...e back door or window and assigned to Zone 2 or 3 Having chosen the location do not mount at this stage Infra Red Remote Reader Location Choose a location near the most frequently entry exit door so t...

Page 6: ...r m Le ar n Err or Z one 1 Z one 2 Z one 3 Z one 4 Z one 5 Z one 6 Z one 8 P A Tam p er Z one 7 Zone Area 1 Front Door 2 Back Door 3 Spare 4 Living room 5 Dining room 6 Kitchen 7 Bedroom 1 8 Bedroom...

Page 7: ...tchen 7 Bedroom 1 8 Bedroom 2 BELLBO X KITCHEN HALL BEDRO O M 2 LS800S CO NTROL UNIT BEDRO O M 1 ZO NE7 ZO NE4 ZO NE8 ZO NE6 ZO NE2 ZO NE1 REM O TE KEY READER The Zone 4 PIR has been placed in the Din...

Page 8: ...ttom Illustration 1 Connect the rechargeable battery on to the control unit and fix it by the battery clips Illustration 2 Err or Lear n Par t Arm Ful l Ar m Pow er TAM P DETECTO R ZONE ZONE 2 1 ZONE...

Page 9: ...n e 1 Z o n e 2 Z o n e 3 Z o n e 4 Z o n e 5 Z o n e 6 Z o n e 8 T a m p e r Z o n e 7 TWO WIRE SYSTEM P A D C BATT 12V 12V AC BATT DC 14V CPTAM 1 CPTAM 1 CPTAM 1 VOLUM E W ALK ALARM TEST CPTAM 1 AC...

Page 10: ...opposite the PIR zone terminals are put in position 1 For connecting two pieces of PIR on the same zone Zone 8 you need to put the corresponding slide switch to position 2 For more information please...

Page 11: ...ing holes in the wall Choose one of the cable entry holes C and make a third hole in the detector base Put one end of the 2 core wire through this hole C then secure the PIR to the wall using two scre...

Page 12: ...ce two wire PIR to the zone you need to set the corresponding switch to position 1 When connecting 2 pieces two wire PIR to the same zone terminals put the corresponding switch to position 2 The wirin...

Page 13: ...itch on the frame Illustration 8 Choose a convenient entry point for the cable on the switch housing and carefully remove part of the plastic using a sharp knife to create a hole Illustration 9 Connec...

Page 14: ...move the cover retaining screw from the base of the bellbox cover Illustration 13 Take off the cover from the bellbox baseplate Use the bellbox baseplate as a template to mark and drill fixing holes I...

Page 15: ...g the push button again at any time will clear the latched LED and walk test is restarted 6 On completion of walk test close the cover of the control unit and an OK tone two rapid beeps is emitted and...

Page 16: ...D STBBELL D IAL VE TIG Power up LS800S control panel 5 rapid beeps Learn LED is flashing Day The panel is in LEARN mode Learn Only zone 1 LED is flashing indicates the first Zone 1 2 remote keys is go...

Page 17: ...on the path between control unit and exit entry zone 6 TW PIR Instant Instant Protect area when part arm is used 7 TW PIR Instant Omit Protect area for full arm only 8 TW PIR Instant Omit Protect area...

Page 18: ...d DELAY two wire PIRs but Omit zone will be inactive i e detectors in the Omit Zone 7 and 8 will be disabled e g at night with people inside house Learn LED flashing System in Learn mode and ready for...

Page 19: ...exact requirements Movement Detector Two wire PIR covers a large area easy to wire Door Window Contact Detector small robust and reliable Remote Key additional remote key for family member to operate...

Page 20: ...be Outputs 12V Aux Output 12V Infra Red Remote Key Type Battery operated infra red signal transmitter Housing ABS Operational distance Up to 12m Operational Voltage 3V Battery type CR2032 PIR Type Dua...