- 20 -
Parameter Value
Note
DAC Out impedance
75 Ohm
Gain According to volume
control setting. 89 dB = 0 dB
with sensitivity normal and rel.
volume 0 dB
Input sensitivity
4.4V (2.2V with high sens.)
200W/8ohms/89 dB Volume
Power Supply Variation
26dB
65V to 3.3V dep. On Volume
Output connectors
4 insulated binding posts, gold-
plated.
Will accept bare wire ends of
up to 5 mm diameter.
Output power, 8ohms
2*200W
1KHz, 0.1% THD+N
Output power, 4ohms
2*375W
1KHz, 0.1% THD+N
Nominal load impedance
4 Ohms-8 Ohms
It is safe to operate the
amplifier with no load.
Frequency response
0.3Hz-33KHz
-3dB points, 8ohms load.
Frequency response
-0dB/+0.2dB 20Hz-20KHz,
8ohms
load
Frequency response
-0.2dB/+0dB
20Hz-20KHz, 4ohms load
Output impedance
0.035 Ohms
20Hz-1KHz
Output impedance
0.4 Ohms
20KHz
THD+N, 1W/8ohms
0.015%
A-wgt.
THD+N, 1W/4ohms
0.02%
A-wgt.
THD+N, 100W/8ohms
0.008%
A-wgt.
THD+N, 180W/8ohms
0.01%
A-wgt.
THD+N, 375W/4ohms
0.07%
A-wgt.
S/N ratio
107dB
A-wgt. Ref. 200W/8ohms.
Dynamic range
133 dB
A-wgt. Ref. 200W/8ohms.
Channel separation
90dB 1KHz,
200W/8ohms.
Peak output current
±40A
Output common mode voltage Max 33V DC
Ref. Ground. The amplifier can
not be used in bridged mono
mode.
Output DC voltage
±5 mV
All audio measurements, except frequency response, are measured with a 20KHz low-
pass filter in accordance with AES-17.
Protection
Parameter Value
Note
Grounding
Mains earth, chassis and audio
ground are connected
internally.
Output short circuit current
±40A
Output DC voltage
±5V @ <0.1Hz
Over temperature
All heat sinks and mains-
transformer.
Auto resetting thermal fuse in
mains transformer.
Mains
Parameter Value
Note
Mains input connector
IEC 320 cold type
Mains lead supplied.
Mains voltage range
100-120V AC, 50–60Hz
115V version