background image

• 6 •

USER MAINTENANCE 

• Unplug and empty unit after each use.

• Do not store water or cleaning solutions in cleaning tank for any long

periods of time.

• Keep unit in cool, dry, ventilated location.

OPERATING INSTRUCTIONS

For step by step instructions please see our instructional videos on the

Lyman Products website at : www.lymanproducts.com

1. Open the lid and remove basket. Place items into basket, then put bas-

ket into the cleaning tank. Add water to a level between MIN and MAX
to cover the items being cleaned.

If the unit is turned on without water, ultrasonic energy will not be
absorbed. This model is high-powered. If turned on for more than 15
seconds without water, it may damage or severely reduce the life of
the unit.

2. Connect the power cord to an outlet and turn the switch on. LED dis-

play shows 05:00. This is the default setting and most common timer
setting and working state. If the timer needs to be adjusted, press
TIME button and 

button. The timer can be set between 1 and 30

minutes. Common cleaning times are 5, 10 or 15 minutes.

Prolonged cleaning time may result in:

a. Loosening of screws (if used).

b. Increasing pre-existing cracks.

c. Peeling of coating which was already separated.

3. Press On/Off button to start cleaning. During cleaning, 2 sets of blue

LED lights at the two sides of the unit illuminate, and a buzzing sound
can be heard from the cleaning tank, indicating that cleaning is under-
way. Closing the lid will reduce the noise level. The digital timer will
count down to show the remaining cleaning time. When it displays
00:00, the cleaning is done.

To stop cleaning at any time, press On/Off button. The unit is designed
with overheating protection to avoid extended and continuous operation
for too long. When the red light is on, the unit will not turn on even by
force. The unit will idle for about 20 minutes and can be restarted after
the green light comes on.

Summary of Contents for Turbo Sonic 6000

Page 1: ...Lyman Turbo Sonic 6000 Ultrasonic Cleaner Operating Instructions ...

Page 2: ...ves cleaning efficiency Cooling fan Built in drain Convenient clean up Multiple circuit protectors SAFETY INSTRUCTIONS CAUTIONS Do not use for loaded cartridges Always unplug this unit when not in use Always keep unit in a safe place to avoid having it fall into water or other liquids Do not immerse in water or other liquids do not spray water or other liquids on unit Always unplug unit immediatel...

Page 3: ... Never let items being cleaned come in contact with the tank Avoid areas that may have electromagnetic interference A Lid B LED Lights C Stainless Steel Tank D Control Panel E Housing F Handles G Drainage Valve Handle H Drainage Pipe I Power Switch J Power Socket K Hose L Power Cord M Plastic Basket FEATURES AND ACCESSORIES ...

Page 4: ...g Function button before it ends will stop de gassing If additional de gassing is needed after it ends press Function button again De Gas When cleaning heavily soiled or greasy items or steel brass silver or copper items chemical solutions need to be added to the water The solution may form many small droplets and take a long time to dissolve in the water Newly added water may generate many air bu...

Page 5: ...imer by 1 minute 12 TC button Heater button Pressing TC button flashes indicating the heater is turned on To cancel heating press TC dims indicating the heater is turned off When the water reaches the set temperature or 140 F 60 C the heater will turn off automatically 13 Temp button Temperature Set button 5 set temperatures can be selected The default temperature is 104 F 40 C Press Temp button t...

Page 6: ...most common timer setting and working state If the timer needs to be adjusted press TIME button and button The timer can be set between 1 and 30 minutes Common cleaning times are 5 10 or 15 minutes Prolonged cleaning time may result in a Loosening of screws if used b Increasing pre existing cracks c Peeling of coating which was already separated 3 Press On Off button to start cleaning During clean...

Page 7: ...the basket Connect the supplied drainage hose to the drain nozzle by pushing straight on Open the drainage valve to drain the dirty water Clean and wipe the tank dry Close the drainage valve Remove drainage hose and rinse with clean water CLEANING SOLUTIONS It is important to use the proper cleaning solutions for the material being cleaned Lyman offers several different ultra sonic cleaning soluti...

Page 8: ...ng cartridge cases remove the basket from the unit and load the shells into the basket Lower the basket into the solution and shake the basket slightly to help dislodge any bubbles that might be present inside the cases After making a new cleaning solution preheat your cleaning solution mix and run the De gas feature on the unit for a minimum of 2 min utes Dissolved gas in the solution can diminis...

Page 9: ... cleaners Can be used to clean steel stainless steel and alu minum gun parts Should NOT be used on bare alu minum and non ferrous metals When cleaning aluminum keep the use of the sonics to the minimum time needed The part s can be allowed to soak no sonics to help in decreasing the time required for sonic cleaning Aluminum can be damaged by excessive sonic energy Designed to clean oil grease and ...

Page 10: ...n mix and run the De gas feature on the unit for a minimum of 2 min utes Dissolved gas in the solution can diminish the ultrasonic energy Once de gassed it is not necessary to de gas again until the solution is changed Discard the solution when it becomes highly discolored or murky Rinse the unit with clean water before recharging Do not mix with other cleaners or chemicals For step by step instru...

Page 11: ...eturned to you within 30 days of our receipt In making any return of a Lyman product to the factory please be sure it is packaged with proper care to protect it from damage in transit We are sorry but our warranty cannot apply to a defect which results from misuse abuse neglect accident or improper care or if your Lyman product has been altered or repaired by anyone other than factory personnel If...

Page 12: ... 4 34 0 cm Rating voltage AC 220 240V 50 60 Hz Frequency AC 100 120V 50 60 Hz Consumption Power AC 220 240V 310W AC 100 120V 290W Digital timer 1 to 30 minute full range timer Temperature Settings 104 F 140 F 40 C 60 C Drainage Drainage Valve Ultrasonic Frequency 35 000 Hz Tank Material Stainless Steel SUS304 Housing Material ABS Net Weight 11 9 lbs 5 4 kg Gross Weight 15 0 lbs 6 8 kg Unit Size 17...