background image

F display Version 1.21 

 

December 2018 

 

 

Page 6 of 26 

 

4. 

Manipulation.

 It is forbidden to intentionally feed artificially generated signals to the 

FLARM  device,  its  GPS  antenna  or  the  external/internal  GPS  antenna  connections,  unless 
agreed with FLARM Technology in writing for limited R&D activities. 
 

5. 

FLARM Data and Privacy 

5.1. 

FLARM  devices  receive,  collect,  store,  use,  send,  and  broadcast  data  to  enable  the 
system to work, improve the system, and to enable troubleshooting. This data may 
include,  but  is  not  limited  to,  configuration  items,  aircraft  identification,  own 
positions,  and  such  data  of  other  aircraft.  FLARM  Technology  may  receive,  collect, 
store,  and  use  this  data  for  said  or  other  purposes  including  Search  and  Rescue 
(SAR). 

5.2. 

FLARM  Technology  may  share  data  with  its  partners  for  aforementioned  or  other 
purposes.  FLARM  Technology  may  in  addition  publicly  make  available  data  from  a 
FLARM  device  (Flight  Tracking).  If  a  FLARM  device  has  been  configured  to  limit 
tracking, SAR and other services may not be available. 

5.3. 

Data  sent  or  broadcast by  FLARM  devices  may only  be  used  at  own  risk  and  under 
the same conditions as the FLARM device itself, and is encrypted partially to ensure 
message  integrity,  system  safety  and  provide  protection  for  the  relevant  content 
against  eavesdropping,  namely  by  article  3  of  the  Budapest  Convention  on 
Cybercrime  as  signed  and  ratified  by  most  countries  respectively  its  national 
implementations.  FLARM  Technology  is  not  responsible  for  any  third  party  device, 
software,  or  service  receiving,  collecting,  storing,  using,  sending,  broadcasting,  or 
making publicly available data regardless of whether legally or illegally. 

 

6. 

Warranty, Limitation of Liability, and Indemnification 

6.1. 

Warranty.

 FLARM devices, software, firmware, license keys, and data are provided 

on  an  "as  is"  basis  without  warranty  of  any  kind  —  either  expressed  or  implied  — 
including, without limitation, any implied warranties of merchantability or fitness for a 
particular  purpose.  FLARM  Technology  does  not  warrant  the  performance  of  the 
device,  software,  firmware,  license  key,  or  data  or  that  the  device,  software, 
firmware, license key, or data will meet your requirements or operate error free. 

6.2. 

Limitation of Liability.

 In no event shall FLARM Technology be liable to you or any 

party related to you for any indirect, incidental, consequential, special, exemplary, or 
punitive damages (including, without limitation, damages for loss of business profits, 
business  interruption,  loss  of  business  information,  loss  of  data  or  other  such 
pecuniary  loss),  whether  under  a  theory  of  contract,  warranty,  tort  (including 
negligence),  products  liability,  or  otherwise,  even  if  FLARM  Technology  has  been 
advised of the possibility of such damages. In no event will FLARM Technology’s total 
aggregate  and  cumulative  liability  to  you  for  any  and  all  claims  of  any  kind  arising 
hereunder exceed the amount of fees actually paid by you for the device, license keys 
or  data  giving  rise  to  the  claim  in  the  twelve  months  preceding  the  claim.  The 
foregoing limitations will apply even if the above stated remedy fails of its essential 
purpose. 

6.3. 

Indemnification.

  You  will,  at  your  own  expense,  indemnify  and  hold  FLARM 

Technology,  and  all  officers,  directors,  and  employees  thereof,  harmless  from  and 
against  any  and  all  claims,  actions,  liabilities,  losses,  damages,  judgments,  grants, 
costs,  and  expenses,  including  reasonable  attorneys’  fees  (collectively,  “Claims”), 
arising out of any use of a FLARM device, software, firmware, license key, or data by 
you, any party related to you, or any party acting upon your authorization. 

 

Summary of Contents for FlarmLED+

Page 1: ...FlarmLED Version 1 2 LXNAV d o o Kidričeva 24 3000 Celje Slovenia tel 386 592 33 400 fax 386 599 33 522 info lxnav com www lxnav com ...

Page 2: ...1 5 Touch pad 13 5 1 6 ALS 13 5 2 Powering up FlarmLED 13 5 3 Normal operation 13 5 3 1 WARNING Modes 13 5 3 2 NEAREST Mode 13 5 3 2 1 Multi target in nearest modus 14 5 3 3 Obstacle warning 14 5 3 4 Alert zone warning 14 5 3 5 Undirected PCAS warning 16 5 3 6 Single target warning 16 5 4 Setting up FlarmLED 17 5 5 Other indications 18 5 5 1 IGC file download 1 18 5 5 2 Running Flarm firmware upda...

Page 3: ...ll be made at no charge to the customer for parts and labor provided that the customer shall be responsible for any transportation cost This warranty does not cover failures due to abuse misuse accident or unauthorized alterations or repairs LXNAV Instrument displays damaged by direct or magnified sunlight are not covered under warranty THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AN...

Page 4: ...LARM device or by downloading installing copying accessing or using any FLARM Technology Ltd Cham Switzerland hereafter FLARM Technology software firmware license key or data you agree to the following terms and conditions If you do not agree with the terms and conditions do not purchase or use the FLARM device and do not download install copy access or use the software firmware license key or dat...

Page 5: ... work if GPS is inoperative degraded or unavailable for any reason 2 6 The most recent Operating Manual must be read understood and followed at all times 2 7 The firmware must be replaced once per year every 12 months The firmware must also be replaced earlier if a Service Bulletin or other information is published with such instruction Failure to replace the firmware may render the device inopera...

Page 6: ...ability and Indemnification 6 1 Warranty FLARM devices software firmware license keys and data are provided on an as is basis without warranty of any kind either expressed or implied including without limitation any implied warranties of merchantability or fitness for a particular purpose FLARM Technology does not warrant the performance of the device software firmware license key or data or that ...

Page 7: ... rights or subsequent actions in the event of future breaches 7 4 Amendments FLARM Technology reserves the right in its sole discretion to amend this Agreement from time to time by posting an updated version of the Agreement on www flarm com provided that disputes arising hereunder will be resolved in accordance with the terms of the Agreement in effect at the time the dispute arose We encourage y...

Page 8: ...FlarmLED display Version 1 21 December 2018 Page 8 of 26 2 Packing Lists FlarmLED Cable ...

Page 9: ...of FlarmLED is part of the Minor Change covering the installation of the FLARM device and must include an AFM Supplement The Minor Change for PowerFLARM Core can be acquired here https flarm com shop easa minor change approval mca Please refer to chapter 5 6 for detailed wiring instructions ...

Page 10: ...ions 6 and 7 FlarmLED is certified in category Standalone 4 1 1 LXNAV FlarmLED display features Extremely bright bicolour LEDs Touch pad to adjust beep volume Near mode function Automatic baud rate detection Low current consumption Adjustable or automatic brightness Multi target indication PCAS indication Distance to the nearest target 4 1 2 Interfaces Serial RS232 input output Touch pad 12 bicolo...

Page 11: ...5 System Description 5 1 Description of FlarmLED It consists of 6 main parts Status LEDs Horizontal direction LEDs Vertical direction LEDs Touch pad Beeper ALS Ambient light sensor Flarm status Distance to the target Horizntal indicator Vertical indicator ALS ...

Page 12: ...lem with connection or no data is received Slow blinking means that GPS status is BAD Solid light means that GPS status is OK 5 1 2 Horizontal direction LEDs They are in yellow or red colour 12 horizontal LEDs are indicating the direction of threat Example shows threat from front right side 1 o clock 5 1 3 Vertical direction LEDs They are in yellow colour LEDs are describing vertical angle of thre...

Page 13: ...l activate a red blinking diode if another aircraft equipped with Flarm will be close and a prediction for a collision risk is calculated An audio warning will be also executed Higher collision risk will increase blinking frequency and audio beep rate The warnings are classified into three levels See Flarm manual for details on www flarm com o First level approximately 18 seconds before predicted ...

Page 14: ... if an obstacle is in the front of the aircraft and a collision risk is predicted The warning is shown with two red LEDs symmetrical around the 12 o clock LED at 10 and 2 they alternate with those at 11 and 1 As we approach to the obstacle the frequency of the alternation increases 5 3 4 Alert zone warning An alert zone warning will be activated if an alert zone is in the front of the aircraft The...

Page 15: ...FlarmLED display Version 1 21 December 2018 Page 15 of 26 ...

Page 16: ...signals without ADS B data contain no direction for the thread therefore you will get an undirected warning with the following alternating signals 5 3 6 Single target warning When the other FLARM device is in a collision path then FlarmLED is going to show red LED with threat direction along vertical angle and distance to it For example next picture indicates threat 11 o clock 14 degrees above and...

Page 17: ...ar mode PCAS setting Volume on beeper Same long touch with two fingers will exit from setup mode Setup mode is indicated with following horizontal indicator image With long touch 1 second to the touch pad we are switching between different settings which can be set Short touch will change value for actual setting First left digit indicates the setting that we are setting second digit right shows t...

Page 18: ...c 0 0 to 99 1 fixed decimal point 0 0 to 9 9 Near mode n 0 OFF default 1 ON one target 2 ON 2 targets 3 ON 3 targets 4 ON 4 targets 5 ON 5 targets 9 ON 9 targets PCAS 1 P 0 PCAS OFF 1 PCAS ON Volume on beeper S 0 Minimum volume 1 Medium 2 maximum default PCAS information will be available if no flarm warnings present and no closer traffic which might be sometimes very annoying 5 5 Other indication...

Page 19: ...D display Version 1 21 December 2018 Page 19 of 26 5 5 2 Running Flarm firmware update 2 5 5 3 Obstacle database update 3 5 5 4 Diagnostic dump 4 5 5 5 Restore file system 5 5 5 6 Internal consistency check 6 ...

Page 20: ...icates highest number On picture below code 120 is shown Error codes are described in the list below 11 Firmware expired requires valid GPS information i e will not be available in the first minute or so after power on 12 Firmware update error 21 Power e g voltage 8V 22 UI error 23 Audio error 24 ADC error 25 SD card error 26 USB error 27 LED error 28 EEPROM error 29 General hardware error 2A Tran...

Page 21: ...guration error e g while reading flarmcfg txt from SD USB B1 Invalid obstacle database license e g wrong serial number B2 Invalid IGC feature license B3 Invalid AUD feature license B4 Invalid ENL feature license B5 Invalid RFB feature license B6 Invalid TIS feature license 100 Generic error 101 Flash File System error 110 Failure updating firmware of external display 120 Device is operated outside...

Page 22: ...1 21 December 2018 Page 22 of 26 5 6 Wiring 5 6 1 FlarmLED pinout Pin number Description 1 N C 2 output Transmit from LXNAV FlarmLED RS232 Level 3 input Receive to LXNAV FlarmLED RS232 Level 4 Ground 5 N C 6 12V DC supply input ...

Page 23: ...18 Page 23 of 26 5 6 2 FlarmMouse FlarmLED 5 6 3 PowerMouse FlarmLED 5 6 4 FlarmBat FlarmLED Flarm Power Supply Cable FlarmLED FlarmMouse Flarm Power Supply Cable FlarmLED PowerMouse Flarm Power Supply Cable FlarmLED FlarmBat V7 Flarm Splitter ...

Page 24: ...ader at https gliding lxnav com lxdownloads firmware S7 PC update tool For the update you need file named _x lxfw x version nr on your computer Update procedure Connect FlarmLED cable to PC and power supply On Tool select communication port to which your FlarmLED is connected to Select baudrate 57600 Select lxfw file Press Flash Apply power to FlarmLED To update FlarmLED a FlarmLED update cable wi...

Page 25: ...FlarmLED display Version 1 21 December 2018 Page 25 of 26 ...

Page 26: ...age 26 of 26 6 Revision History November 2018 Initial release of this manual November 2018 Reviewed updated chapters 4 1 5 2 5 1 2 Added chapters 5 3 6 November 2018 Added Flarm EULA and installation chapter December 2018 Flarm EULA and misc typos ...