Summary of Contents for VX3X

Page 1: ...s obsolete This electronic guide has been made available as a courtesy to our customers Contact your LXE representative for replacement and assistance E EQ VX3XOGWW G ARC 2010 Copyright by LXE Inc An...

Page 2: ...of Summit Data Communications Inc The Cisco Square Bridge logo is a trademark of Cisco Systems Inc Aironet Cisco and Cisco Systems are registered trademarks of Cisco Systems Inc and or its affiliates...

Page 3: ...Power Connection 10 Connect Power Cable 12 Connecting the Headset Cable 13 Adjust Headset Microphone and Secure Cable 14 Connecting a Tethered Scanner 15 Attach Stylus Tether and Sleeve 15 Set Date an...

Page 4: ...onnection Indicator 22 Reboot 23 Warm Boot 23 Cold Boot 23 Troubleshooting 23 Regulatory Notices and Safety Information 24 Class A Digital Device 24 RF Notices 25 RF Safety Notice 25 Lithium Battery S...

Page 5: ...nect a tethered scanner to the VX3X l Place the VX3X in a powered dock or cradle Hardware Setup 1 Connect accessories 2 Connect cables 3 Connect power cable 4 Secure all cables to the VX3X with the St...

Page 6: ...s Components Front 1 Endcap 2 Display 3 Programmable Key 4 Beeper 5 On Off Button 6 2nd LED 7 Alt LED 8 Ctrl LED 9 Shift LED 10 Caps LED 11 Status LED 12 Programmable Key E EQ VX3XOGWW G ARC 2 VX3X Us...

Page 7: ...Back Back 1 RAM Ball 2 Power Connector 3 Strain Relief Clamp E EQ VX3XOGWW G ARC 3 VX3X User Guide...

Page 8: ...Right Port 4 Audio Jack or External Antenna Connector Audio Jack shown Endcap Options Left Port Right Port COM3 RS 232 USB Client USB C COM3 RS 232 COM1 RS 232 USB Host USB H COM1 RS 232 USB Host USB...

Page 9: ...e mouse pointer then left clicking icons on a desktop computer screen Using the stylus to tap icons on the touchscreen is the basic action that can l Open applications l Choose menu commands l Select...

Page 10: ...T The next keypress is an ALT keypress Amber when on and unlit when off CTRL The next keypress is a CTRL keypress Amber when on and unlit when off SHFT The next letter is the uppercase letter on alpha...

Page 11: ...ter 2 on the cable provides a USB Host connection Connect Cable USB Client Prerequisite An endcap with a USB Client port labeled USB C A commercially available standard USB cable with a type A plug on...

Page 12: ...the serial COM port on the VX3X endcap 2 Turn the thumbscrews in a clockwise direction Do not over tighten 3 Use a strain relief clamp to secure the cable to the VX3X 4 Connect the other cable end to...

Page 13: ...rated 12 80 VDC minimum 15W75W The external power supply may be connected to either a 120V 60Hz supply or outside North America to a 230V 50Hz supply using the appropriate detachable cordset In all ca...

Page 14: ...ting rating fuse If the supply connection is made directly to the battery the fuse should be installed in the positive lead within 5 inches of the battery positive terminal Note For North America a UL...

Page 15: ...made at any point after the ignition switch of the vehicle 3 Route the power cable the shortest way possible The cable is rated for a maximum temperature of 75 C 167 F When routing this cable it shoul...

Page 16: ...e to the VX3X Connect Power Cable 1 Connect the power cable to vehicle power See Vehicle 12 80VDC Power Connection 2 The plug and receptacle are keyed and care must be used when connecting the cables...

Page 17: ...rophone Connect the VX3X voice cable I O connector to the I O port on the VX3X The VX3X internal microphone and speaker are automatically disabled Slide the voice cable ends together until they click...

Page 18: ...about two finger widths from your mouth Make sure the microphone is pointed at your mouth Note the small Talk label near the mouthpiece Make sure the Talk label is in front of your mouth The micropho...

Page 19: ...t selected The COM port that accepts the scanner data can be configured for data rate parity stop bits and data bits Attach Stylus Tether and Sleeve The stylus kit includes the stylus tether and sleev...

Page 20: ...rches the Internet for a time server A connection to the Internet is required for this option Autolaunch Time Sync Start Settings Control Panel VX3X Options Communication tab By default TimeSync does...

Page 21: ...he CAPS key to type all capital letters l Tap the key to access symbols Some applications do not automatically display the Input Panel In this case do the following to use the Input Panel Input Panel...

Page 22: ...ume until the speaker volume is satisfactory Press the Enter key to exit this mode The LED for the 2nd key blinks until the special editing mode set audio speaker volume is complete Volume control usi...

Page 23: ...tab in the Power control panel When the backlight timer expires the display backlight is dimmed not turned off When both checkboxes are unchecked the backlight never turns off or dims Default values...

Page 24: ...mber Telnet Port of the host system to properly set up your host session 1 Make sure the mobile client network settings are configured and functional If you are connecting over wireless LAN 802 11x ma...

Page 25: ...t application in the AppLock configuration is moved to the foreground and the previous application moves to the background The previous application continues to run in the background VX3X key presses...

Page 26: ...targeted Bluetooth device during the discovery and pairing process If the devices are in Suspend tap the power key to wake the VX3X Using the correct procedure wake the targeted Bluetooth device if ne...

Page 27: ...ype COLDBOOT EXE or COLDBOOT This command is not case sensitive2 Tap the OK button Note Because of the extreme nature of cold boot LXE recommends using this command only as an emergency or when instru...

Page 28: ...ons Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Page 29: ...ories not provided by LXE should not be used with this device This device must not be co located or operating in conjunction with any other antenna or transmitter R TTE Directive Requirements Applies...

Page 30: ...tteria venga sostituita in maniera scorretta Sostituire solo con lo stesso tipo o equivalente consigliato per il fabbricante IT Aten o Cont m pilha de l tio H perigo de explos o no caso de uma substit...

Page 31: ...lenta da 2 A nel conduttore positivo a meno di 5 in 12 7 cm dal terminale positivo della batteria IT Tilkople str mforsyningen til kj ret yet Hvis str mforsyningen koples direkte til batteriet skal d...

Page 32: ...cting Cables 7 Connecting the Headset Cable 13 Connecting Vehicle Power 10 Connection Indicators 22 D Date Time TimeZone 16 Daylight Savings location 16 G Grab Time Utility 16 H Hardware Setup 1 Heads...

Page 33: ...connectors for use with 22AWG conductors11 Software Setup 1 Stylus how to use 5 Switchpad 21 Sync button 16 Synchronize with a Local Time Server 16 T Touchscreen and the stylus 5 Touchscreen protecti...

Reviews: