LVD OASIS 504844 Instructions Manual Download Page 14

M8SBF

M12SBF

1/4" UNION FITTING

CHILLER AND FOUNTAIN CONNNECTIONS 

FILTER CONNECTION

(BOTTLE FILLER AND FOUNTAIN)

FIG. 7

FILTER CLIP

FRONT

 OF CHILLER

PLACE FILTER

IN CLIP AS 

SHOWN

FIG 5

STEP 7

STEP 8

FILLER DELIVERY TUBE

SOLENOID
VALVE 

OUT

SOLENOID
VALVE 

IN

PROVIDED BALL
VALVE AND 3/8"
O.D. COPPER
TO BUILDING
WATER SUPPLY

CHILLER

1 1/4"TAILPIECE

A

C

B

D

E

USE EXCESS TUBE TO CONECT FOUNTAIN 
TO CHILLER TEE

F

G

H

A

C

B

D

OUT

TO BOTTLE
FILLER DELIVERY
TUBE

STEM
ELBOWS

FIG. 8

FROM PROVIDED
BALL VALVE

1/4" UNION TEE
CHILLER 

OUT

CONNECT TO
FOUNTAIN AND
BOTTLE FILLER
SOLENOID 

IN

1/4" UNION CHILLER 

IN

CONNECTS TO BALL VALVE
OF FILTER OUT (IF USED)
FITTINGS PROVIDED

DRAIN
COMPONENTS
NOT INCLUDED

1 1/4" TAILPIECE
(TRAP NOT INCLUDED)

DETERMINE LENGTH OF TUBE NEEDED TO
CONNECT BOTTLE FILLER SOLENOID 

OUT

TO BOTTLE FILLER DELIVERY TUBE, CUT
OFF EXCESS

REMOVE ADAPTER FITTING AND COPPER
TUBE FROM FOUNTAIN WATER LINE.  INSTALL
PROVIDED 1/4" UNION

INSTALL CHILLER IN FRAME

INSTALL 1/4" UNION ON CHILLER 

IN

CONNECT 1/4" UNION TEE TO CHILLER 

OUT

ATTACH REMAINING TUBE FROM BALL VALVE
TO CHILLER 

IN

DETERMINE TUBE LENGTH NEEDED TO
CONNECT BOTTLE FILLER SOLENOID 

IN

(THE LINE WITH ATTACHED BALL VALVE) TO
CHILLER TEE.  CUT TUBE AND CONNECT

CONNECT TUBING FROM BALL
VALVE TO FILTER 

IN

.  CONNECT

FILTER 

OUT

 TO CHILLER 

IN

.

CUT THE TUBE TO THE CHILLER
INLET

INSTALL PROVIDED STEM
ELBOWS (SEE FIG. 8)

MOUNT FILTER TO CHILLER
CASING (SEE FIG. 5)

IN

SHORT RADIUS
TRAP REQUIRED

Summary of Contents for OASIS 504844

Page 1: ...g upper short fountain first then connect water tube assembly provided to its water inlet Hang lower longer fountain next and connect the tube to its water inlet supply line For combination units with chillers hang upper short unit first and connect chiller tube assembly provided containing tee to fountain water inlet tube with compression fitting provided and then to chiller unit water out fittin...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...the bottom l Remove the bottom plate from the fountain arm Save the screws m Snap the reveal gasket over the back end of the fountain arm n Add compression connector furnished by others to the fountain waste tube and slide back approximately 3 out of the way Refer to the appropriate connection diagram o Hang the fountain on the mounting plate studs NOTE AS THE FOUNTAIN IS HUNG FEED THE WASTE TUBE ...

Page 9: ......

Page 10: ......

Page 11: ...SLIDE CRADLE BETWEEN ANGLES AND ATTACH TO ANGLES WITH SCREWS PROVIDED TIGHTEN ALL SCREWS UPPER FRONT PANEL MOUNTS TO FRAME WITH BOTTOM SCREWS COOLING UNIT MOUNTING CRADLE WALL MOUNTING FRAME SECURES INTO WALL WITH FACE FLUSH WITH FINISHED WALL OPTIONAL FILTER SEE STEP 6 COOLING UNIT OPTIONAL MOUNTS INSIDE CRADLE CRADLE MOUNTING ANGLES 2 PROVIDED UV KIT ACCESSORY SEE STEP 9 TRIM BEZEL ACCESSORY SEE...

Page 12: ...SCREWS PROVIDED INSTALL LOWER LOUVER PANEL USING SUPPLIED LOCKS OR SCREWS STRAINER INSIDE FIG 1 FIG 2 A D C B 2X4 JUNCTION BOX FILTER INSTALLATION IN OUT TO BOTTLE FILLER DELIVERY TUBE STEP 3 WITHOUT CHILLER STEM ELBOWS A C B D E FIG 3 A C B DRAIN COMPONENTS NOT INCLUDED INSULATED TUBE CONNECTS TO FILLER TUBE SEE STEP 3 PROVIDED BALL VALVE AND DRAIN COMPONENTS NOT INCLUDED 3 8 O D COPPER TO BUILDI...

Page 13: ...BOWS FIG 6 FIG 5 WITHIN CHILLER B A C INSTALL 1 4 UNION FITTINGS ON CHILLER INLET AND OUTLET PLACE CHILLER IN FRAME ATTACH CRADLE TO FRAME PER ROUGH IN DRAWING SCREWS PROVIDED 4 RUN THE WATER LINE FROM THE BOTTLE FILLER SOLENOID VALVE OUT TO CHILLER IN CUT OFF EXCESS AND USE IT TO RUN FROM CHILLER OUT TO THE BOTTLE FILLER DELIVERY TUBE SCREW FILTER CLIP TO UNIT IN LOCATION INSTALL 1 4 STEM ELBOWS ...

Page 14: ... OF FILTER OUT IF USED FITTINGS PROVIDED DRAIN COMPONENTS NOT INCLUDED 1 1 4 TAILPIECE TRAP NOT INCLUDED DETERMINE LENGTH OF TUBE NEEDED TO CONNECT BOTTLE FILLER SOLENOID OUT TO BOTTLE FILLER DELIVERY TUBE CUT OFF EXCESS REMOVE ADAPTER FITTING AND COPPER TUBE FROM FOUNTAIN WATER LINE INSTALL PROVIDED 1 4 UNION INSTALL CHILLER IN FRAME INSTALL 1 4 UNION ON CHILLER IN CONNECT 1 4 UNION TEE TO CHILLE...

Page 15: ...D REFER TO FIG 10 AND 11 FOR DETAILS INSTALL QUARTZ SLEEVE WITH O RING INTO UV HOUSING ASSEMBLE RETAINER NUT DO NOT OVER TIGHTEN REFER TO FIG 10 FOR DETAILS RUN UV POWER CORD CONNECTION THROUGH HOLE PROVIDED IN FRAME CONNECT UV BULB TO POWER SUPPLY CORD AND INSERT BULB INTO UV HOUSING SEE FIG 9 AND 10 FOR DETAILS HOLE PROVIDED FOR ELECTRICAL AND WATER RUN STEP 9 STEP 10 CAUTION CAREFULLY SNAP UV H...

Page 16: ...ILLER DELIVERY TUBE SEE FIG 2 IN STEP 2 OF THESE INSTRUCTIONS REMOTE CHILLER OPTIONAL FILTER ASSEMBLY OPTIONAL UV HOUSING AND BALLAST A AA BB B NOTE IF OPTIONAL FILTER ASSEMBLY IS NOT INSTALLED CONNECTION A WILL CONNECT TO LOCATION AA OF THE UV ASSEMBLY IF OPTIONAL REMOTE CHILLER IS NOT INSTALLED CONNECTION B WILL CONNECT TO LOCATION BB OF THE UV ASSEMBLY ...

Page 17: ...NSTALLATION HEIGHT REMOVE BOTTOM PLATE FROM TRIM BEZEL 4 SCREWS INSTALL TRIM BEZEL TO FRAME ASSEMBLY AND REPLACE BOTTOM PLATE WITH SCREWS INSTALL DRAIN ASSEMBLY SNAP BUSHINGS AND ANY OTHER ACCESSORIES INCLUDED WITH THIS KIT INSTALL UPPER AND LOWER FRONT PANEL D E C B A FIG 11 FRAME ASSEMBLY TRIM BEZEL TRIM BEZEL BOTTOM PLATE WITH SCREWS UPPER AND LOWER FRONT PANELS FASTENING POINTS ON FRAME ...

Page 18: ...MODULAR SPORTS BOTTLE FILLER OASIS MWSBF MW8SBF MW12SBF M8SBF M12SBF ILLUSTRATED PARTS BREAK DOWN ...

Page 19: ...MODULAR SPORTS BOTTLE FILLER OASIS MWSBF MW8SBF MW12SBF M8SBF M12SBF ILLUSTRATED PARTS BREAK DOWN ...

Page 20: ...TRATED PARTS BREAK DOWN FLOW RESTRICTOR THIS FLOW RESTRICTOR IS INTENDED TO MAKE YOUR WATER FLOW AT THE PROPER RATE PRESS THE FLOW RESTRICTOR FIRMLY INTO THE TUBING PROVIDED INSERT THE TUBING WITH THE FLOW RESTRICTOR INTO ELBOW FITTING AT THE TOP FITTING OF THE SOLENOID VALVE ...

Reviews: