[Setup Procedures] 

1. Referring to Diagram 1, connect both ELD-A Vertical Shafts to the ELB-A 

Controller via the supplied Patch Cords.    Next connect the ELH-A Manual 
Controller  (refer  to  Diagram  2)  and  supplied  Power  Cord  to  the  ELB-A 
Controller. 

2.  In  line  with  controller  name  plate,  plug  the  controller  into  the  electricity 

supply  (either  230V  AC  or  120V  AC).  The  digital  display  will  show  “RST”.   
Press the “DOWN” button until the push rod reaches the bottom of its limit.   
Release the depressed DOWN button. The digital display will show

 

560(unit: 

mm).    The initial setup and a reset have been completed. 

3.  After  successfully  resetting  the  unit,  depress  the  Manual  Controller  “UP” 

button.  Both  Vertical  Shafts  will  ascend  at  the  same  time  and  stop  when 
pressure is released from the “UP” button. 

4.  Depress  the  Manual  Controller  “DOWN”  key.  Both  Vertical  Shafts  will 

descend  at  the  same  time  and  stop  when  pressure  is  released  from  the 
“DOWN” button 

 

[Table Height Memory] 

Four different heights can be memorized for future use. Via the “UP/DOWN” 
buttons select your preferred height of the table then press the “S” button 
followed by any of the four numerical buttons on the Manual Controller. The 
height  of  the  table  will  be  retained  in  the  Manual  Controllers  memory.  A 
further  three  different  heights  can  be  preset  by  selecting  a  different 
numerical button after depressing the “S” button on the Manual Controller.   
Thereafter the preset table heights can be selected simply by pressing the 
numerical  buttons  associated  with  the  desired  table  height.  These  preset 
table heights will be retained in the memory of the Manual Controller even 
after  a  power  reset.  After  pressing  one  of  the  four  numerical  buttons  to 
select  a  preset  height  the  “UP/DOWN”  buttons  can  be  used  to  manually 
override your selection.   

 

[Vertical Shaft Synchronization Problems] 

 

If the two Vertical Shafts do not synchronize correctly, they can be reset by 
either an Automatic Reset or a Manual Reset. 
 

Automatic Reset 

Depress  the  “DOWN”  button  on  the  Manual  Controller  continually  until  the 

Vertical  Shaft  descends  to  the  bottom  and  then  rises  approximately  5mm.   
Remove  pressure  from  the  “DOWN”  button.    The  Automatic  reset  is  now 
complete and the unit should function normally. 

Manual Reset

 

Reviews: