background image

Blood Pressure Monitor

LXBP100

INSTRUCTION MANUAL

SVENSKA / ENGLISH

Summary of Contents for LXBP100

Page 1: ...Blood Pressure Monitor LXBP100 INSTRUCTION MANUAL SVENSKA ENGLISH...

Page 2: ...av manualen Portabla och mobila enheter med tr dl s kommunikation kan p verka medicinsk elektronisk utrustning Thank you for purchasing this product from Luxor If you need the instruction manual in l...

Page 3: ...19 Specifikationer 20 Milj lag och s kerhet f rbeh ll 21 Complied European Standard Lists 40 EMC Guidance 41 47 CONTENT Safety Instructions and Symbols 22 23 Parts 24 Display 25 Installing and Replac...

Page 4: ...tt sl ppa ut luften Skulle manschetten mot f rmodan inte sl ppa ut luften trycker du p START STOP f r att stoppa uppbl sningen Anv nd inte blodtrycksm taren i milj er med starka elektromagnetiska f lt...

Page 5: ...anualen m ste l sas Symbol f r typ BF Bluetooth symbol Symbol f r auktoriserad representant i Europa Symbol f r tillverkare Symbol f r tillverkningsdatum Symbol f r att produkten verensst mmer med kra...

Page 6: ...6 SVENSKA DELAR 1 Systoliskt 2 Diastoliskt 3 Pulsfrekvens 4 LCD display 5 Minne Upp 6 Start Stopp 7 Tid 8 SET Ner 9 Armband 10 Batterifack 1 2 3 4 5 6 7 8 9 10...

Page 7: ...skt blodtryck Undre blodtryck Puls Slag Minut L gt batteri L gt batteri byt batterier Enhet M tningsenhet IHB registrerare Registrerar oj mna hj rtslag Irregular Heartbeat Detector Bluetooth Lyckad Bl...

Page 8: ...visas p displayen N r displayens ljusstyrka d mpas Om displayen inte startar n r du s tter p blodtrycksm taren F rsiktig Tag ur batterierna om enheten inte ska anv ndas under en l ngre tid Uttj nta ba...

Page 9: ...nappen igen f r att bekr fta tidsinst llningen Nu kommer siffran som representerar minuter att blinka C 4 Upprepa steg 2 och 3 f r att st lla in och bekr fta tidsinst llningen f r minuter D 5 Upprepa...

Page 10: ...ndet runt din handled med din handflata upp t 4 S tt kanten av armbandet ungef r 1 1 5 cm upp p din handled 5 F st armbandet runt din handled se till att den sitter h rt och ordentligt Om armbandet si...

Page 11: ...Ladda ner Luxor Smart Health Companion appen fr n App Store S k efter och installera appen i din iPhone eller iPad Tryck p Smart Health ikonen f r att ppna appen F rs kra att b de appen och Bluetooth...

Page 12: ...atiskt 2 M taren kommer automatiskt verf ra datan till appen direkt efter t Bluetooth symbolen kommer att blinka 3 Om verf ringen lyckas kommer displayen se ut enligt bilden nedan till v nster Om verf...

Page 13: ...en i 3 sekunder 2 Displayen kommer att visa dEL dONE n r minnet har raderats 3 Om du vill avbryta raderingen tryck p START STOPP knappen f r att st nga av displayen M tningarnas noggrannhet Felaktiga...

Page 14: ...Under varje m tning registrerar utrustningen hj rtslagens intervaller och r knar ut avvikelser fr n standarden Symbolen kan visas n r du pratar r r dig eller n r du har oregelbundna hj rtslag F rsikti...

Page 15: ...m tresultatet hamnar utanf r klassificeringarna V nligen notera att endast en l kare kan avg ra om ditt blodtryck n tt ett v rde som kan vara farligt Optimal Normal Hypertoni G1 G2 G3 SYS 120 121 130...

Page 16: ...dicin 3 V nta minst 3 minuter innan du g r en ny m tning Varf r r blodtrycket jag hade p sjukhuset annorlunda fr n det jag m tte hemma Blodtrycket r annorlunda ven under en 24 timmarsperiod p grund av...

Page 17: ...t in nya batterier Fel meddelande error Visar error och Bluetoothsymbol verf ringen har misslyckats Kontrollera att appen r p pr va sedan att verf ra igen Error 1 Armbandet bl ser upp sig sakta eller...

Page 18: ...en M t igen Error 10 eller error 11 Enheten uppfattade r relse eller s r pulsen f r svag Slappna av en stund och m t igen Error 20 Enheten uppt ckte ingen puls d den kan vara f r f r svag Ta bort kl d...

Page 19: ...orr trasa Undvik att skaka enheten eller att tappa den Undvik dammiga milj er och extrema temperaturer Undvik att tv tta manschetten Reng ring Dammiga milj er kan p verka enhetens prestanda Anv nd en...

Page 20: ...40 C Fuktighet 80 Tryck 86kPa 106kPa F rvaringsmilj Temperatur 20 60 C Fuktighet 10 93 RH Armbandets omkrets 13 5 cm 21 5 cm Vikt 120 g Dimensioner 80 65 22 mm Vattenskydd IP22 Mjukvaruversion v1 0 Bl...

Page 21: ...T Detta m rke finns p produkten och i manualen f r att visa att den uppfyller de europeiska s kerhets och elektromagnetiska kraven Denna produkt r tillverkad enligt g llande regler f r elektromagnetis...

Page 22: ...exceeds 40 kPa 300 mmHg the unit will automatically deflate Should the cuff not deflate when its pressure exceeds 40 kPa 300 mmHg detach the cuff from the wrist and press the START STOP button to stop...

Page 23: ...r The operation guide must be read Symbol for Type BF Applied Parts Bluetooth symbol Symbol for Authorized Representa tive in the European Community Symbol for manufacturer Symbol for Manufacture date...

Page 24: ...24 ENGLISH PARTS 1 Systolic 2 Diastolic 3 Pulse Rate 4 LCD Display 5 Memory Up Button 6 Start Stop 7 Time 8 Set Down Button 9 Cuff 10 Battery Compartment 1 2 3 4 5 6 7 8 9 10...

Page 25: ...blood pressure Minimum blood pressure Pulse Beat Minute Low Battery Low battery replace the batteries Unit Measurement unit of blood pressure IHB Detector Irregular Heartbeat Detector Bluetooth Succes...

Page 26: ...following circumstances When is shown on the display When the display dims When powering on the monitor and the LCD doesn t light up Caution Remove batteries if the device is not likely to be used for...

Page 27: ...ll increase the numeral by one in a cycling manner 3 Press SET button again to confirm HOUR Then the numeral representing MINUTE blinks C 4 Repeat step 2 and 3 to confirm MINUTE D 5 Repeat step 2 and...

Page 28: ...ng up 4 Position the edge of the cuff about 1 1 5 cm up on you wrist 5 Fasten the wrist cuff around your wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measure...

Page 29: ...xor 1 Download Luxor Smart Health Companion app from App Store You may search and install the app in your iPhone or iPad Tap the Smart Health icon to open the app Ensure that both Bluetooth and the Ap...

Page 30: ...complete the measurement process automatically 2 The device will automatically proceed to data transmission right after measurement The Bluetooth symbol will blink 3 If the data transmission fails th...

Page 31: ...button and the SET button for 3 sec 2 The display will show dEL dONE indicating that the memory clearing is complete 3 If you wish to give up the clearing press START STOP to turn off the monitor Meas...

Page 32: ...heartbeat intervals and works out the standard deviation If the heartbeat intervals compare with the average intervals the deviation more than 3 is over 25 or more than 5 is over 15 this equipment wi...

Page 33: ...ur measuring result falls out of the range Kindly note that only a physician could tell whether your blood pressure value has reached a dangerous point Optimal Normal Hypertension G1 G2 G3 SYS 120 121...

Page 34: ...you take medicine 3 Wait at least 3 minutes for another measurement Why is the blood pressure I get from the hospital different from home The blood pressure is different even during 24 hour because o...

Page 35: ...Replace with new batteries Error message Shows error or Bluetooth symbol Data communication has failed Check if the app is on or not try data transmission again Error 1 Inflation is slow or the cuff i...

Page 36: ...Error 11 The monitor detected motion talking or the pulse is too poor while measuring Relax for a moment and then measure again Error 20 The measurement process does not detect the pulse signal Loosen...

Page 37: ...se Avoid shaking and collision Avoid dusty environment and unstable temperature surrounding Avoid washing the cuff Cleaning Dust environment may affect the performance of the unit Please use the soft...

Page 38: ...ition Temperature 5 40 C Humidity 80 Pressure 86kPa 106kPa Storage condition Temperature 20 60 Humidity 10 93 RH Measurement of wrist 13 5 cm 21 5 cm Weight 120 g Dimensions 80 65 22 mm Water protecti...

Page 39: ...or more information LAW AND SAFETY This product has been manufactured according to current regulations for electromagnetic fields EMF which means that it is safe to use if used according to safety ins...

Page 40: ...ual EN 1041 2008 General Requirements for Safety EN 60601 1 2006 AC 2010 EN 62304 2006 AC 2008 EN 60601 1 6 2010 EN 60601 1 11 2010 Non invasive Sphygmomanometers General Requirements EN 1060 1 1995 A...

Page 41: ...below The customer or the user of the device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 2 The devi...

Page 42: ...sed in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV ai...

Page 43: ...cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s Not applicable Mains power quality should be that of a typical commercial or hospital environment If the user of the device requires c...

Page 44: ...assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150...

Page 45: ...ffected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios am...

Page 46: ...radiated RF disturbances are controlled The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communica...

Page 47: ...ended separation distance in metres m can be estimated using the equation applicable to the frequency of the transmitter where is the maximum output power rating of the transmitter in watts W accordin...

Page 48: ......

Reviews: