VACUUM TUBE CONTROL AMPLIFIER CL-38uC
7
23. Monitor input terminals (MONITOR)
Are used to connect output terminals for playback of a
recorder.
These terminals are connected to the line output terminals
of a recorder.
When the monitor switch is set to on, these terminals are
selected regardless of the position of the input selector.
24. Balanced input terminals/INPUTS
(BAL LINE)
Are the balanced type input terminals of the LINE level for
an XLR connector.
This unit uses the balanced input system with use of a
transformer.
Be aware that the maximum input level at the balanced
input is 2.5 V and therefore sound signals may be distorted
if a device with larger output level is connected.
* If the device is LUXMAN’s product (such as CD player),
no problem occurs. Refer to the operating instructions
for the device to be used for further information.
25. Phase inverters (PHASE)
Change the phase when the balance input terminal is used.
The phase shall be corresponding to the phase of the input
device.
NORMAL position
①
GROUND
②
COLD (–)
③
HOT (+)
INVERT position
①
GROUND
②
HOT (+)
③
COLD (–)
26. Line output terminals/OUTPUTS
(LINE-1 and LINE-2)
Are used to provide output this unit. Two lines, LINE-1 and
LINE-2, are provided, and same signals will be output from
both lines. (Both are always on.)
While using one side of the line output terminal, do not
insert a shortpin plug to the other line output terminal. No
sound will be generated.
27. AC inlet (AC IN)
Connects the accessory power cable. The power shall be
supplied from a household wall socket.