background image

2

Features of This Unit

LECUTA
LUXMAN Electronically Controlled 
Ultimate Transformer Attenuator

The 34-contact transformer type attenuator in which 
FINEMET

®

 core is used is switched with paired 34 pieces 

of relays. The transformer type attenuator can suppress the 
DC resistance generated in series with the signal transmis-
sion line.
FINEMET

®

 manufactured by Hitachi Metals, Ltd. is used 

for the core material of the transformer type attenuator like 
MQ-300, and therefore, this attenuator features excellence 
in the audible frequency characteristic and little change in 
sound quality because of low permeability and low core loss 
in a wide band.
Minimization and the same length of the connection wires 
between the attenuator and relays at all the 34 contacts can 
make changes in sound quality due to sound levels minimize.

Vacuum tube amplification circuit

The attenuator driver circuit, tone control circuit, and flat am-
plifier circuit contain a vacuum tube manufactured by JJ Elec-
tronic (Slovakia) (E88CC x 6).

Vacuum tube, E88CC-JJ

E88CC is an SQ (abbreviation of Special Quality) tube whose 
characteristics are the same as those of the reliable tube and 
features low noise.

Phono equalizer circuit equipped in EXT-IN

The phono equalizer circuit that contains FET and an op-
erational amplifier is used. MM, MC, or impedance can be 
selected in accordance with the cartridge to be used. The 
capacitor that we recommend can be also selected.

Balanced input circuit

A dedicated super permalloy transformer is equipped in the 
input circuit.

Balance output circuit

A dedicated super permalloy transformer is equipped in the 
output circuit.

PHASE INVERT function

The phase can be switched in accordance with the polarity 
of the balanced input or output device to be connected to 
this unit.
The phase of the unbalanced output of this unit can also be 
switched.

ARTICULATOR function

Clear sound can be reproduced thanks to demagnetization 
and tuning of the attenuator transformer.
After the power is turned on, the attenuator transformer is au-
tomatically demagnetized during the mute function activated.
This operation can be conducted even manually with the use 
of the ARTICULATOR switch.
A signal is generated by the internal oscillator, this signal is 
gradually decreased, and then the attenuator transformer is 
demagnetized. If the internal oscillator is not in use, the power 
of it is turned off. Therefore, the oscillator does not interfere 
with the audio circuit at the normal use.

Eliminating resistance of audio signal line

Elimination of the resistance generated in series with the au-
dio signal line from input to output allows sound quality deg-
radation to be reduced and superior sound reproduction to 
be realized. (Resistance is present when phono equalizer is 
activated and the LINE STRAIGHT switch is set to off)

Tone control

LUX type tone control circuit is used, which is a classic style.
This unit is also equipped with the bass/treble tone control 
function that can select the turnover frequency from three po-
sitions to allow the tone quality to be finely adjusted.

Wooden top cover

A U-shaped wooden top cover is used, which matches with 
classic design.
Gloss coating finish with rosewood color is applied on walnut 
veneer.

Summary of Contents for CL-1000

Page 1: ...VACUUM TUBE CONTROL AMPLIFIER CL 1000 Owner sManual...

Page 2: ...Contents Precautions 1 Features of This Unit 2 Names and Functions 4 Connections 9 Operations 12 Block Diagram 13 Specifications 14 Before Asking for Repair Service 16...

Page 3: ...The pin plug to be inserted in each input terminal of this unit shall be pushed in firmly If the grounding terminal is inade quately connected noises including hum may be generated resulting in an adv...

Page 4: ...the input circuit Balance output circuit A dedicated super permalloy transformer is equipped in the output circuit PHASE INVERT function The phase can be switched in accordance with the polarity of th...

Page 5: ...ng structure Every block of the vacuum tube has a floating structure to reduce microphonic noise Cast iron insulator This unit is equipped with gradation cast iron insulators that cuts out unnecessary...

Page 6: ...played back The EXT IN is used for PHONO input 3 Low frequency selector switch FREQUENCY Hz Toggles to select frequencies from 150 Hz 300 Hz 600 Hz For example when 150 is selected the frequencies of...

Page 7: ...sound volume between right and left channels Rotating the control counterclockwise gradually cuts the volume of the right channel rotating the control clockwise gradually cuts the volume of the left c...

Page 8: ...ncy characteristics of the high frequency range When this switch is set in the center position flat frequency characteristics is obtained Rotating the knob clockwise makes the high frequency range enh...

Page 9: ...als INPUTS LINE 1 LINE 2 LINE 3 Coaxial input terminal to receive unbalanced audio signals of a line level Connect these terminals to an unbalanced output of an input device such as a CD player with a...

Page 10: ...als to provide balanced audio signals from this unit Connect these terminals to a balanced input of an output device such as a power amplifier with a balanced cable Audio output signals are selected w...

Page 11: ...function Connect the output of an analog player with phono equal izer embedded to the line input of this unit How to connect the input terminals to input devices such as a CD player Connect between th...

Page 12: ...10 Connections Normal stereophonic playback CD SACD PLAYER L R L R L R L R GND POWER AMP 1 POWER AMP 2 L R L R SPEAKER SYSTEM 1 L R SPEAKER SYSTEM 2 L R D A CONVERTER ANALOG PLAYER...

Page 13: ...UM TUBE CONTROL AMPLIFIER CL 1000 POWER AMP L ch POWER AMP R ch L LOW R LOW L HIGH R HIGH SPEAKER SYSTEM L R CD SACD PLAYER L R L R L R L R GND D A CONVERTER ANALOG PLAYER Bi amplifier stereophonic pl...

Page 14: ...hen the balance adjustment is not required the balance control is set to the center position When the line straight switch LINE STRAIGHT is set to on the right and left sound volumes cannot be changed...

Page 15: ...ELAY TREBLE VOLUME BASS VOLUME TURNOVER RELAY PHASE SELECT RELAY BAL IN FLAT AMP STRAIGHT RELAY PHASE SEL RELAY OUT PUT BAL 1 LINE 2 LINE 1 BAL 2 MUT BAL UNBAL FLAT AMP BAL UNBAL RELAY MUTE RELAY LOW...

Page 16: ...dB 1 V output 20 Hz to 20 kHz load 50 k EXT IN PHONO 0 3 dB 1 V output 20 Hz to 20 kHz load 50 k S N ratio LINE BAL LINE 120 dB IHF A distortion 1 1 kHz load 50 k EXT IN PHONO MM 108 dB IHF A distorti...

Page 17: ...ower cable Owner s Manual This document Terminal protection cap Safety cautions Power supply 230 V 50 Hz Power consumption 52 W Max external dimensions 460 W x 166 H x 454 D mm including 13 5 mm front...

Page 18: ...minimum level Rotate the volume control or attenuator of the power amplifier to adjust the sound volume The input selector is not set to the source to be reproduced Set the input selector to the sour...

Page 19: ......

Page 20: ...LUXMAN CORPORATION AG00987E90A Printed in Japan 1 3 1 Shinyokohama Kouhoku ku Yokohama shi Kanagawa 222 0033 Japan...