7.2

 

Auto Mode 

If no DMX control signal is present at the DMX input 

[3

 or 

4]

, the unit independently runs through its 

show programme (if the blackout mode is switched off). 

1.

 

Press MENU until <AUTO> appears on the display. Press ENTER to confirm. 

2.

 

Select one of the auto programmes (programme 0-4) with UP or DOWN. Press ENTER to confirm. 

3.

 

Set the running speed (0-100 %) with UP or DOWN. Press ENTER to save the setting. 

 

IMPORTANT: The auto programmes 0-4 are fully pre-programmed and will not be altered by changes. 

Instead, the <MANU C> mode allows combining the colours RGBWAP (red, green, blue, 
white, amber, purple). 

1.

 

Press MENU until <STATIC> appears on the display. Press ENTER to confirm. 

2.

 

Select <MANU C> with UP or DOWN and press ENTER to confirm. 

3.

 

Select the colour (RGBWAP) with UP or DOWN and press ENTER to confirm. 

4.

 

Set the value (000-255) with UP or DOWN. Press ENTER to save the setting. 

5.

 

Press MENU to go back. 

7.3

 

Static Mode 

This unit has the ability to accept custom static colour settings. 

1.

 

Press MENU until <STATIC> appears on the display. Press ENTER to confirm. 

2.

 

Select <FIXT C> with UP or DOWN and press ENTER to confirm. 

3.

 

Select the colour with UP or DOWN and press ENTER to confirm. 

4.

 

Press MENU to go back. 

7.4

 

Master/Slave Mode 

This mode allows you to link up several units together without using a controller. Choose the first in the 
chain to function as master unit; other connected units will work as slave units with the same effect. 

1.

 

Press MENU until <M&S> appears on the display. Press ENTER to confirm. 

2.

 

According the master or slave unit, select <MASTER> or <SLAVE> with UP or DOWN and press 
ENTER to confirm. 

3.

 

Select the desired programme (see 

7.3 Auto Mode

). 

4.

 

Use standard DMX cables to daisy chain your units together via the DMX connections 

[3

 or 

4

 + 

5

 or 

6]

 on the rear of each unit. We suggest using a terminator on the last unit for longer cable runs 

(see 

7.10 Construction of the DMX Termination

). 

7.5

 

Linking 

Several units may be interconnected in order to control all further slave units to the same effect as the 
master unit. 

1.

 

Connect the DMX output 

[5

 or 

6]

 of the master unit to the DMX input 

[3

 or 

4]

 of the first slave unit 

using an appropriate cable with XLR connector. 

2.

 

Connect the DMX output 

[5

 or 

6]

 of the first slave unit to the DMX input 

[3

 or 

4]

 of the next slave 

unit using an appropriate cable with XLR connector, until all units are connected in a chain. 

7.6

 

DMX Configuration 

This device is equipped with different DMX configurations. 

1.

 

Press MENU until <CHANNEL> appears on the display. Press ENTER to confirm. 

2.

 

Select the desired DMX configuration (6ch, 8ch, 12ch, HSV or HSI) with UP or DOWN and press 
ENTER to confirm. 

3.

 

Refer to chapter 

7.11 DMX Value per Channel

 to set each channel. 

7.7

 

DMX Mode 

1.

 

Press MENU until <ADDRESS> appears on the display. Press ENTER to confirm. 

2.

 

Select the desired value (001-512) with UP or DOWN (hold UP or DOWN pressed to scroll rapidly) 
and press ENTER to confirm. 

3.

 

Press MENU to go back. 

 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the 

signals. This digital start address is the channel number from which the device starts to “listen” to 
the DMX controller. The same starting address can be used for a whole group of devices or an 
individual address can be set for every device. 

Summary of Contents for LX119

Page 1: ...LX119 SMART HEXA LED PAR 12 X 12 W RGBWAP LED USER MANUAL...

Page 2: ...LX119 V 01 19 06 2014 2 Velleman nv...

Page 3: ...ice Keep this device away from children and unauthorized users Caution device heats up during use Do not stare directly at the light source as this may cause epileptic seizure in sensitive people temp...

Page 4: ...ent of 240 VAC 50 Hz Lighting effects are not designed for permanent operation regular operation breaks will prolong their lives Use the original packaging if the device is to be transported Keep this...

Page 5: ...urrent does not exceed the power line s nominal current Use power cables with an adequate section The installation has to be approved by an expert before the device is taken into service DMX 512 Conne...

Page 6: ...the master or slave unit select MASTER or SLAVE with UP or DOWN and press ENTER to confirm 3 Select the desired programme see 7 3 Auto Mode 4 Use standard DMX cables to daisy chain your units together...

Page 7: ...controller not incl and the other side to the male XLR input 3 or 4 of the device Multiple devices can be linked through serial linking The linking cable shall be a dual core screened cable with XLR i...

Page 8: ...000 255 amber 0 100 6 000 255 white 0 100 7 000 255 purple 0 100 8 000 10 no function 011 255 strobe slow fast 9 000 10 no function 011 30 red 100 green 0 100 blue 0 031 50 red 100 0 green 100 blue 0...

Page 9: ...IM1 DIM2 or DIM3 with UP or DOWN and press ENTER to confirm 3 Press MENU to go back BackLite Activation of the display backlight 1 Press MENU until BACKLITE appears on the display Press ENTER to confi...

Page 10: ...use by a fuse of the same type and rating 1 Before replacing the fuse unplug the mains lead 2 Unscrew the fuse holder 12 with an appropriate screwdriver 3 Remove the old fuse and install the new fuse...

Page 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...