without deforming. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a 
qualified technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the 

installation material to be used… Have the material and the device itself checked regularly. Do not 
attempt to install the device yourself if you lack these qualifications as improper installation may 
result in injuries. 

 

For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the 
(folded) bracket. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5 m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. All devices must be powered directly off a 
grounded switched circuit. Do not connect to a dimmer pack. 

 

The device has a power output 

[10]

 to supply power to another device. When connecting several 

devices in a daisy chain via this output, make sure that the total current does not exceed the power 
line’s nominal current. Use power cables with an adequate section. 

 

The installation has to be approved by an expert before the device is taken into service. 

DMX-512 Connection 

 

When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the 

other side to the male XLR input 

[3

 or 

4]

 of the device. Multiple devices can be linked through serial 

linking. The linking cable should be a dual core, screened cable with XLR input and output 
connectors. 

 

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended 
number of devices on a serial data link is 32 devices. 

 

A DMX terminator is recommended for installations where the DMX cable has to run a long distance 

or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the 
digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω 
resistor between pins 2 and 3, which is then plugged into the XLR output socket 

[5

 or 

6]

 of the last 

device in the chain. 

7.

 

Operation 

The device can be used in the following modes: 

 

stand-alone mode 

 

master/slave 

 

with a DMX512 controller. 

7.1

 

Control Panel 

Access the control panel functions using the four panel buttons located 
directly underneath the display 

[7]

. From left to right: 

 

Button 

Function 

MENU 

 

access the menu 

 

return to a previous menu option 

UP 

 

scroll through the menu options in ascending order 

 

increase value 

DOWN 

 

scroll through the menu options in descending order 

 

decrease value 

ENTER 

 

select menu option 

 

store the current menu or option within the menu 

 

Summary of Contents for LX119

Page 1: ...LX119 SMART HEXA LED PAR 12 X 12 W RGBWAP LED USER MANUAL...

Page 2: ...LX119 V 01 19 06 2014 2 Velleman nv...

Page 3: ...ice Keep this device away from children and unauthorized users Caution device heats up during use Do not stare directly at the light source as this may cause epileptic seizure in sensitive people temp...

Page 4: ...ent of 240 VAC 50 Hz Lighting effects are not designed for permanent operation regular operation breaks will prolong their lives Use the original packaging if the device is to be transported Keep this...

Page 5: ...urrent does not exceed the power line s nominal current Use power cables with an adequate section The installation has to be approved by an expert before the device is taken into service DMX 512 Conne...

Page 6: ...the master or slave unit select MASTER or SLAVE with UP or DOWN and press ENTER to confirm 3 Select the desired programme see 7 3 Auto Mode 4 Use standard DMX cables to daisy chain your units together...

Page 7: ...controller not incl and the other side to the male XLR input 3 or 4 of the device Multiple devices can be linked through serial linking The linking cable shall be a dual core screened cable with XLR i...

Page 8: ...000 255 amber 0 100 6 000 255 white 0 100 7 000 255 purple 0 100 8 000 10 no function 011 255 strobe slow fast 9 000 10 no function 011 30 red 100 green 0 100 blue 0 031 50 red 100 0 green 100 blue 0...

Page 9: ...IM1 DIM2 or DIM3 with UP or DOWN and press ENTER to confirm 3 Press MENU to go back BackLite Activation of the display backlight 1 Press MENU until BACKLITE appears on the display Press ENTER to confi...

Page 10: ...use by a fuse of the same type and rating 1 Before replacing the fuse unplug the mains lead 2 Unscrew the fuse holder 12 with an appropriate screwdriver 3 Remove the old fuse and install the new fuse...

Page 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...