12
DMX Mode
DMX addressing
The device is controlled by universal DMX 512 protocol, DMX address is the start channel
used to receive instructions from the external controller. For independent control, each fixture
must be assigned its unique address control channels. For example, this device has four
channel modes: 20/21/15/17, if we set the mode at standard 18 channels mode, and there
are several models need to be independently controlled, we just simply address first fixture at
1, and second fixture at 21, third one at 41, etc.
If the devices have the same address, they will behave synchronically.
DMX addressing is limited, don’t set the address so high that without enough control
channels for the fixtures.
Display is flashing when no DMX signal is received.
Connection
Use DMX cable with 5-pin XLR-plugs to connect the controller with the fixture or one fixture
with another.