Page 1: ...ithout further notice No rights can be derived from this manual No part of this manual may be reproduced in any form or by any means without prior written consent from AED Distribution NV Belgium Luxi...

Page 2: ...he product as described herein contains components that emit UVC light Immediate or prolonged exposure to UVC light can result in painful injury such as eye injury skin burn premature skin aging or sk...

Page 3: ...ry which can be poisonous at certain con centrations Avoid direct or indirect lighting on eyes or skin of humans or animals exposure to direct or strongly reflected UVC light Basic safety instructions...

Page 4: ...must strictly observe the instructions set out herein If you are an employee or are acting on be half of another person your employer that person must instruct you in accordance with the Manual and e...

Page 5: ...s may no longer emit the required level of ultraviolet radiation to ensure the desired effect on bacteria or fungi Technical data Type B Air Voltage 230 V 50 Hz power factor 0 989 Isolation Class I re...

Page 6: ...perature range from 15 C to 25 C 6 3 Remove the shipping assembly Remove the tape from the box and open the box Take the unit out of box and remove wrapping that protects the unit Make a visual inspec...

Page 7: ...disconnected prior to connecting the unit or making any changes to cabling con figurations Electrical installation must be carried out correctly by authorized electricians Standard 230V 50Hz Brown Li...

Page 8: ...disconnect the power supply Clean the external surfaces with a soft cloth and non aggressive cleaning agents only 8 1 Air filters Luxibel recommends to clean out the airfilters at least twice a year...

Page 9: ...e from the holders 7 Insert the new lamp with the dowels into the slots of the holders and rotate it about 90 around the axis to lock it 8 Slide unit back inside and reconnect earth cable 9 Install th...

Page 10: ...nd working methods known to us at the time of issue of the manual and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instruct...

Page 11: ...AED Distribution NV Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com www AEDgroup com...