background image

 

 
Website: 

www.luxielectronics.com

 

Email: 

[email protected]

 

 

 
Phone: +1 (949) 654-2047 
Address: Irvine, CA, USA 

 

Document name: THB-350 quick start guide 

Revision: 1.01 

Date: 7/19/2017 

Specifications are subject to change without notice 

power off command via RS-232 ports of both THB-350 and RHB-350 with a set delay time (1 to 60 
minutes) after the last input signal disappears; and will send a display power on command as soon as 
the first input signal detected, and will automatically select that input.  The switcher uses one RS-232 
port to connect both external host (optional; only required for setup) and display in parallel with the 
display in “listening” mode only (only display’s Rx pin connected).  Here’s the wiring diagram: 

Ext host

THB-350

RHB-350

Display

Rx

--------------

Tx

Tx

--------------

Rx

Tx

--------------

Rx

Via Cat6

Rx

NC

NC

Ground

--------------

Ground

Ground

--------------

Ground

NC = Not Connected

 

Use the “2{xxx}R” and “1{yyy}R” commands listed in next page to setup the display power on and off 
commands respectively, then use the “1*zR” command to enable the display power control feature 
while setting the power off delay time at “z” minutes.  Use “0R” command to disable the display power 
control feature.  Once setup finished, the external host is not needed for daily operations.  The system 
reset command “r” will not erase the stored display power on and off commands, but will disable the 
display power control feature (factory default). 
 

Support: 

Please contact your reseller directly for local support; or Luxi using the contact info in the 

header.  See Luxi website for additional and more updated documents. 

 

Luxi THB-350 scaler Tx RS-232 commands

Rev 1.01

Function

Command 
to THB-350

Response from THB-350

Notes

Factory default

Product information commands

Query device part number

p

74-040-01¶

Numeric and dash only

MCU firmware version

1P

x.xx¶

Numeric only

Scaler firmware version

2P

x.xx¶

Numeric only

Splitter firmware version

3P

x.xx¶

Numeric only

HDBT firmware version

4P

x.xx¶

Numeric only

Reset command

Reset to factory defaults

r

Reset

Input selection commands

Select local input x

x s

Input 

x

 live¶

x has 3 possible values, 1 thru 3

2s (HDMI input)

Set auto switch on

0s

Auto sw on¶

Will release by new input selection

Input 

x

 live¶

Auto sw on (or off)¶
Input 

x

 signal present¶

Input 

x

 signal present¶

Front panel sw off¶
Auto sw off¶
Front panel sw on¶
Auto sw off¶
Front panel sw off¶
Auto sw on¶
Front panel sw off (or on)¶
Auto sw on (or off)¶

Scaler commands

Initiate auto image

a

Auto image on¶

Set output format to pixel to pixel

0o

Output format pixel to pixel

Only supports 7 preset resolutions: 720p, 
1080p, 1280x800, 1920x1200, 1024x768, 
1280x1024, 1600x1200

Set output format to 720p

1o

Output format 720p

Set output format to 1080p

2o

Output format 1080p

2o (output 1080p)

Set output format to 1280x800

3o

Output format 1280x800¶

Set output format to 1920x1200

4o

Output format 1920x1200¶

Set output format to 1024x768

5o

Output format 1024x768¶

Set output format to 1280x1024

6o

Output format 1280x1024¶

Set output format to 1600x1200

7o

Output format 1600x1200¶

Query output format

o

(One of the responses from 
cell C30 to C37)

Set zoom level on

x

z

Zoom level 

x has 6 possible values, 1 thru 6

1z (zoom level 1)

Query zoom level

z

Zoom level 

Press and hold 
front panel switch 
for about 7 
seconds will toggle 
the auto sw on or 
off; LED fast 
blinking 3 or 2 
times respectively

Allow auto switching and defeat 
front panel input selection

2A

When front panel switch pressed, the LED 
fast blinking 3 times

2A (auto sw on, 
front panel sw off)

Defeat front panel input selection

0A

When front panel switch pressed, the LED 
fast blinking twice

Allow front panel input selection

1A

Query local input status

s

Send all 3 groups of status to "s" command, 
only one group of status to the one just 
changed

Query front panel switch status

A

 

See Luxi website for more commands 

Summary of Contents for THB-350

Page 1: ... power audio RS 232 and contact controls are supplied with the unit Separate the wires about 1 2 5 cm long strip off the wire insulation precisely 3 16 5 mm from the end Identify the positive and negative leads for power Luxi power supply has a white stripe on the positive wire If not sure use a multi meter to verify Mounting options Luxi has the under desk mount Luxi P N 78 002 01 or the MediaHub...

Page 2: ...nt panel switch status 0A is to turn off auto switching and defeat front panel and contact closure controls 1A is to turn off auto switching and allow front panel and contact closure controls 2A default is to turn on auto switching and defeat front panel contact closure controls Auto image settings Command a is to initiate auto image settings Scaler output video format settings Refer to RS 232 o s...

Page 3: ...ler firmware version 2P x xx Numeric only Splitter firmware version 3P x xx Numeric only HDBT firmware version 4P x xx Numeric only Reset command Reset to factory defaults r Reset Input selection commands Select local input x xs Input x live x has 3 possible values 1 thru 3 2s HDMI input Set auto switch on 0s Auto sw on Will release by new input selection Input x live Auto sw on or off Input x sig...

Page 4: ...00 pixel to pixel High efficiency fanless design for ultimate reliability HDBT output up to 70 m 235 with Cat6 cable POC 24 V Rack mountable under table mountable above projector Audio signal path There are 3 audio inputs and 3 audio mountable metal enclosures outputs The digital audio embedded in HDMI and DP inputs Package are selected by a HDMI switcher then goes to the scaler One piece in one c...

Reviews: