![Luxaire TCJD30 THRU 76 Technical Manual Download Page 17](http://html1.mh-extra.com/html/luxaire/tcjd30-thru-76/tcjd30-thru-76_technical-manual_1951788017.webp)
700678-LTG-E-0415
Johnson Controls Unitary Products
17
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
ACCESSORIES & APPLICATIONS
Refer to Price Manual for specific model numbers.
Long Lineset Applications -
For installations with more than
75' of equivalent lineset length, refer to the current version of
the
Piping Application Guide 247077-UAD-H-0209
, available
in the Application Bulletins section on UPGnet.
Off Cycle Timer Delay
- Provides a 5-minute off cycle to pre-
vent rapid recycling of the compressor.
TXV Kits -
S1-1TVM series thermal expansion valves precisely
meter refrigerant for optimum performance over a wide range of
conditions. See System Charge table for TXV part number for
each model.
Low Ambient Pressure Switch Kit (S1-2LA06700424) -
Allows the use of air conditioning at low outdoor ambient tem-
peratures down to +20°F (-7°C). For use with single-stage
models containing R-410A refrigerant only.
Thermostats
- Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
TCJD60S4(3,4)S4(E)
T*(8,L)C*C20
21.0
FC/MC/PC60D
1600
54.0
37.6
13.25
11.25
T*(8,L)C*C20
21.0
FC/MC62D
1620
55.0
39.1
13.50
11.25
T*(8,L)C*C20
21.0
FC64D
1630
57.0
40.6
14.00
11.75
T*(8,L)C*C20
21.0
UC60C
1605
54.0
37.6
13.25
11.25
T*(8,L)V*C20
21.0
FC/MC/PC60D
1600
54.0
37.6
13.25
11.25
T*(8,L)V*C20
21.0
FC/MC62D
1620
55.0
39.1
13.50
11.25
T*(8,L)V*C20
21.0
FC64D
1630
57.0
40.6
14.00
11.75
T*(8,L)V*C20
21.0
UC60C
1605
54.0
37.6
13.25
11.25
T*9(C,V)*C20
21.0
FC/MC62D
1655
55.0
39.1
13.25
11.00
T*9(C,V)*C20
21.0
FC64D
1655
57.0
40.6
13.50
11.25
T*9(C,V)*D20
24.5
FC/MC62D
1630
55.0
39.1
13.25
11.00
T*9(C,V)*D20
24.5
FC64D
1630
57.0
40.6
13.50
11.50
TM8X080C16MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TM8X100C16MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TM8X100C20MP11
21.0
FC64D
1600
56.5
39.7
13.50
11.50
TM8X120C20MP11
21.0
FC64D
1600
56.5
39.7
13.50
11.50
TM9E100C20MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TM9E120D20MP11
24.5
FC64D
1525
56.0
39.2
13.25
11.25
TM9X100C20MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TM9X120D20MP11
24.5
FC64D
1525
56.0
39.2
13.25
11.25
TMLX080C16MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TMLX100C16MP11
21.0
FC64D
1550
56.0
39.2
13.25
11.25
TMLX100C20MP11
21.0
FC64D
1600
56.5
39.7
13.50
11.50
TMLX120C20MP11
21.0
FC64D
1600
56.5
39.7
13.50
11.50
L*(8,L)C*C20
21.0
FC/MC/PC60D
1600
54.0
37.6
13.25
11.25
L*(8,L)C*C20
21.0
FC/MC62D
1620
55.0
39.1
13.50
11.25
L*(8,L)C*C20
21.0
FC64D
1630
57.0
40.6
14.00
11.75
L*(8,L)C*C20
21.0
UC60C
1605
54.0
37.6
13.25
11.25
L*9C*C20
21.0
FC/MC62D
1655
55.0
39.1
13.25
11.00
L*9C*C20
21.0
FC64D
1655
57.0
40.6
13.50
11.25
L*9C*D20
24.5
FC/MC62D
1630
55.0
39.1
13.25
11.00
L*9C*D20
24.5
FC64D
1630
57.0
40.6
13.50
11.50
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
COIL
MODEL
1
COOLING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
13 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES
2
Application Limits
Maximum Lineset Equivalent Length
75 Ft
Outdoor Ambient Temperature Limits
Cooling Operation
Maximum DB
115°F
Minimum DB