Subject to change without notice. Published in U.S.A.
5443703-LTG-B-0418
Copyright © 2018 by Johnson Controls, Inc. All rights reserved.
Supersedes: 5443703-LTG-A-1017
York International Corp.
5005 York Drive
Norman, OK 73069
PERFORMANCE DATA - 5 TON
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 °
F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTICE
Outdoor units must be applied with Johnson Controls Unitary Products indoor coils, so Condenser Only data is not provided.
COOLING PERFORMANCE DATA - HIGH
AIR CONDITIONER MODEL NO.
AL21B6021S
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
IDCFM
1530
1800
1980
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
55
T.C.
51.3
53.7
54.6
58.4
59.8
52.9
55.0
55.6
58.6
59.6
54.4
56.3
56.5
58.7
59.4
S.C.
34.7
35.5
35.7
39.4
40.2
36.0
36.8
36.9
39.6
40.1
37.3
38.0
38.0
39.7
40.0
KW
2.60
2.58
2.58
2.56
2.54
2.67
2.66
2.66
2.63
2.62
2.74
2.73
2.73
2.71
2.70
65
T.C.
51.3
53.8
54.6
58.9
62.7
53.0
55.1
55.6
59.5
62.9
54.7
56.4
56.6
60.2
63.1
S.C.
34.7
36.1
36.3
40.1
42.4
36.1
37.2
37.3
40.5
42.6
37.5
38.2
38.3
41.0
42.8
KW
3.13
3.13
3.13
3.13
3.13
3.21
3.22
3.22
3.21
3.22
3.30
3.30
3.30
3.29
3.31
75
T.C.
51.3
53.8
54.6
59.3
65.5
53.1
55.1
55.6
60.5
66.2
54.9
56.4
56.6
61.7
66.8
S.C.
34.7
36.7
36.8
40.8
44.6
36.2
37.6
37.7
41.5
45.1
37.6
38.4
38.5
42.2
45.5
KW
3.65
3.69
3.68
3.70
3.72
3.76
3.78
3.78
3.79
3.82
3.86
3.87
3.87
3.88
3.91
85
T.C.
51.3
53.9
54.7
59.8
65.5
53.2
55.2
55.7
60.8
66.5
55.1
56.5
56.7
61.8
67.5
S.C.
35.3
37.3
37.4
41.3
45.3
36.6
38.2
38.2
42.0
45.9
37.9
39.0
39.0
42.8
46.6
KW
4.49
4.52
4.52
4.56
4.60
4.59
4.62
4.62
4.65
4.69
4.69
4.71
4.71
4.75
4.79
95
T.C.
51.3
53.9
54.8
60.2
65.5
53.3
55.3
55.8
61.1
66.9
55.3
56.6
56.7
61.9
68.2
S.C.
35.9
37.9
37.9
41.7
45.9
37.1
38.8
38.7
42.5
46.8
38.2
39.6
39.4
43.3
47.7
KW
5.33
5.36
5.36
5.42
5.47
5.42
5.46
5.46
5.51
5.57
5.52
5.55
5.55
5.61
5.67
105
T.C.
47.6
49.8
50.1
55.5
61.3
49.5
51.0
51.1
56.6
62.7
51.4
52.2
52.1
57.6
64.0
S.C.
34.1
35.6
35.8
39.5
43.3
35.5
36.5
36.5
40.2
44.2
36.8
37.3
37.2
40.8
45.1
KW
5.90
5.94
5.94
6.00
6.08
6.01
6.04
6.03
6.10
6.17
6.12
6.14
6.13
6.20
6.27
115
T.C.
44.2
45.8
46.0
52.1
56.5
45.8
47.1
46.9
53.3
57.7
47.3
48.3
47.7
54.4
58.8
S.C.
31.3
32.8
32.9
36.7
40.4
32.7
33.8
33.6
37.5
41.2
34.0
34.8
34.3
38.3
41.9
KW
6.50
6.52
6.52
6.59
6.68
6.59
6.60
6.61
6.68
6.77
6.68
6.69
6.70
6.77
6.87
125
T.C.
39.5
41.8
41.4
46.7
52.2
41.1
42.9
42.5
47.5
53.1
42.6
44.0
43.6
48.2
53.9
S.C.
28.4
30.1
30.4
33.7
37.4
29.7
31.0
31.0
34.3
38.0
30.9
31.9
31.6
34.8
38.6
KW
7.15
7.21
7.19
7.27
7.34
7.24
7.29
7.28
7.36
7.43
7.34
7.37
7.36
7.45
7.52
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.
COIL MULTIPLIERS - 5 TON
Air Handler
Coil
T.C.
S.C.
KW
AVV61CE421
–
1.00
0.98
1.04
AVV61DE421
–
1.00
1.00
1.00
MVC20DN21
CM61DE4A1
1.00
0.99
1.00
FURNACE MULTIPLIERS - 5 TON
Furnaces
Coil
T.C.
S.C.
KW
TM8V100C20MP12C
CM61CE4A1
1.00
0.97
1.04
TM8V120C20MP12C
CM61CE4A1
1.00
0.97
1.04
TM9V100C20MP12C
CM61CE4A1
0.99
0.98
1.06
TM9V120D20MP12C
CM61DE4A1
1.00
0.96
1.04
TMLV100C20MP12C
CM61CE4A1
1.00
0.97
1.04
TMLV120C20MP12C
CM61CE4A1
1.00
0.97
1.04
TP9C100C20MP13C
CM61CE4A1
0.99
0.98
1.06
TP9C120D20MP13C
CM61DE4A1
1.00
0.96
1.04
TPLC100C20MP13C
CM61CE4A1
1.00
0.97
1.04
TPLC120C20MP13C
CM61CE4A1
1.00
0.97
1.04
LP9C100C20MP13C
CM61CE4A1
0.99
0.98
1.06
LP9C120D20MP13C
CM61DE4A1
1.00
0.96
1.04
LPLC100C20MP13C
CM61CE4A1
1.00
0.97
1.04
LPLC120C20MP13C
CM61CE4A1
1.00
0.97
1.04
FURNACE MULTIPLIERS - 5 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW