background image

TECHNICAL GUIDE

ACCLIMATE

TM

 

SERIES

SPLIT SYSTEM 
AIR CONDITIONERS

20 SEER – R-410A – 1 PHASE

2 THRU 5 NOMINAL TONS

MODELS: AL21B24 THRU 60

Due to continuous product improvement, specifications 
are subject to change without notice.
Visit us on the web at 

www.upgnet.com and www.luxaire.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY SUMMARY*

Extended 10-Years limited parts warranty.

Extended Lifetime limited compressor warranty.

Extended parts and compressor warranties

 require online

registration within 90 days of purchase for replacement or
closing for new home construction.

*Does not apply to 3-Phase models, or Internet sales.

See Limited Warranty certificate in User's Information Manual for details.

FOR INSTALLATION IN ALL US REGIONS AND CANADA

Installation Allowed

Š

5443703-LTG-B-0418

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The Acclimate™ Series AL21 variable capacity air conditioners
are the outdoor section of a high efficiency communicating cool-
ing system. They are designed as part of a matched system
using an AVV air handler or variable speed communicating fur-
nace with a CM coil. Both the matched CM coil and AVV air
handler have factory mounted EEVs. The CM coils with factory
mounted EEVs can also be matched with the variable speed
MVC modular air handlers.

FEATURES

Superior Coil Protection –

 An easily removable two-piece

steel extruded louver coil guard protects the tube-in-fin coil
from debris and physical damage while making access for
coil cleaning quick and simple.

Environmentally Friendly Refrigerant –

 The next genera-

tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.

Durable Finish –

 A high quality powder paint finish rated at

1000 hrs. salt spray provides the ultimate protection from
corrosion and harmful UV rays, ensuring a long-lasting, high
quality appearance.

Charge Smart™ –

 A built-in touch screen instantly displays

the system overall condition, including the system pressures
and refrigerant charge without the need to attach additional
gauges or sensors.

SilentDrive™ System –

 Features a combination of engi-

neered, sound-neutralizing attributes such as a swept-wing
fan blade, composite base pan, multi-density compressor
cloak and variable capacity operation to reduce sound levels
to that of a mere conversation.

ECM Fan Motor –

 Dynamically adjusts speed in sync with

the compressor demand to keep heat exchange in balance
while minimizing power consumption and sound.

Swept Wing Fan –

 A design adapted from aerospace engi-

neering provides whisper-quiet operation by allowing air to
flow smoothly and efficiently across the fan surface and
edges.

Composite Base Pan –

 The strong and durable composite

base pan is corrosion resistant while adding strength,
absorbing sound, and reducing vibration.

High-Efficiency Outdoor Coil –

 An aluminum fin and cop-

per tube outdoor coil provide easy cleaning, low restriction to
airflow and efficient heat exchange.

Factory Installed Filter-Drier –

 A corrosion resistant copper

solid core liquid line filter-drier removes debris and moisture
which can be harmful to the system.

Climate Sync™ –

 provides pre-configured operating profiles

the installing contractor can select during set-up to fine tune
the system's operation for either Humid, Dry, or Normal cli-
mates. Additional fine-tune adjustments are always available
to provide a custom comfort solution.

Easy Service Access –

 A large electrical box cover, inde-

pendent Charge Smart access, and a swing open electrical
box provide superior full corner access to the inside of the
unit for maintenance or service.

System Protection –

 Each system contains high and low

pressure transducers which constantly monitor system per-
formance and can alert the consumer or contractor system
concerns or alerts.

EEV Controls –

 All indoor coils, whether in the cased CM

coil or in the AVV air handler, have factory installed EEVs
(Electronic Expansion Valves).

Summary of Contents for ACCLIMATE AL21 Series

Page 1: ...ng high quality appearance Charge Smart A built in touch screen instantly displays the system overall condition including the system pressures and refrigerant charge without the need to attach additio...

Page 2: ...rranty when registered online within 90 days of installa tion Agency Listed Safety certified by CSA to UL 1995 CSA 22 2 Performance certified to ANSI AHRI Standard 210 240 in accordance with the Unita...

Page 3: ...2 Rows Deep 1 1 2 2 Fins Inch 22 22 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 3 4 3 4 7 8 7 8 Unit Charge Lbs Oz 4 7 8 7 6 14 9 15 1 Charge Per Foot...

Page 4: ...the system charge without attaching a separate manifold gauge set or temperature sensors 6 Permanently mark the unit data plate with the total amount of refrigerant in the system SYSTEM CHARGE FOR VA...

Page 5: ...r If OD Unit is Below ID Unit 24 3 8 3 4 80 feet 25 feet 25 feet 36 48 7 8 60 NOTICE Inverter Temperature Protection If excessive inverter temperatures are sensed the compressor speed capacity is redu...

Page 6: ...0 19 05 Low 475 14 20 11 30 35 70 AL21B4821S AVV49DE321 24 5 High 1550 45 50 34 40 20 00 13 00 Med 800 25 20 18 50 19 10 Low 525 14 90 11 50 36 20 AL21B4821S MVC16CN21 21 0 CM49CE3A1 High 1450 45 50 3...

Page 7: ...75 9 9 8 2 37 20 AL21B2421S LP9C060B12MP13C 17 5 CM25BE1A1 High 775 23 0 17 4 20 50 14 25 Med 475 13 8 10 8 19 05 Low 325 9 7 7 7 36 35 AL21B2421S LP9C080B12MP13C 17 5 CM25BE1A1 High 825 23 4 18 3 20...

Page 8: ...C080B12MP13C 17 5 CM37BE2A1 High 1250 34 6 26 4 19 00 12 20 Med 725 18 9 15 4 18 15 Low 475 11 0 9 6 33 05 AL21B3621S LP9C080C16MP13C 21 0 CM37CE2A1 High 1125 34 8 25 6 19 25 13 00 Med 650 18 6 14 8 1...

Page 9: ...LV120C20MP12C 21 0 CM49CE3A1 High 1525 45 5 33 2 19 50 12 50 Med 875 25 0 20 0 18 65 Low 675 14 4 11 1 34 05 AL21B4821S TP9C080C16MP13C 21 0 CM49CE3A1 High 1500 45 5 32 8 19 50 12 25 Med 775 25 0 19 1...

Page 10: ...0C20MP12C 21 0 CM61CE4A1 High 1675 52 5 37 6 19 75 12 50 Med 1100 30 2 24 6 18 95 Low 825 20 6 17 8 35 95 AL21B6021S TM8V120C20MP12C 21 0 CM61CE4A1 High 1675 52 5 37 6 19 75 12 50 Med 1100 30 2 24 6 1...

Page 11: ...0 6 17 8 35 95 AL21B6021S LP9C100C20MP13C 21 0 CM61CE4A1 High 1750 52 0 37 8 19 75 12 20 Med 1050 30 4 24 4 19 10 Low 700 20 4 16 3 37 05 AL21B6021S LP9C120D20MP13C 24 5 CM61DE4A1 High 1650 52 5 37 2...

Page 12: ...icient inte rior unit access for removing the compressor through the side of the unit UNIT CONSTRUCTION Units shall be shipped completely wired piped and assem bled Wiring pigtails shall be provided f...

Page 13: ...GHTXDWH ZDOO VXSSRUW 87 21 6SHFLDO FDUH PXVW EH WDNHQ WR DYRLG UHFLUFXODWLRQ RI GLVFKDUJH DLU WKURXJK RXWGRRU FRLO CAUTION Care must be taken to prevent ice from damaging the unit Damage may occur fro...

Page 14: ...080 5 1 7 1 81 76 127 OHDUDQFH EHWZHHQ WZR XQLWV PD EH UHGXFHG WR PLQLPXP SURYLGHG WKH VHUYLFH DFFHVV FOHDUDQFH LV LQFUHDVHG WR PLQLPXP DQG WKH FOHDUDQFH RQ HDFK UHPDLQLQJ VLGH LV PDLQWDLQHG DW PLQLP...

Page 15: ...6 14 6 15 3 15 5 17 0 19 1 KW 1 62 1 61 1 61 1 60 1 57 1 65 1 64 1 65 1 63 1 60 1 68 1 68 1 68 1 66 1 63 95 T C 20 0 21 5 21 5 24 7 27 1 20 8 22 4 22 5 25 3 28 3 21 6 23 2 23 4 25 9 29 5 S C 13 8 14...

Page 16: ...5 2 86 2 88 2 89 2 90 2 85 2 87 2 94 2 95 2 96 2 86 2 87 105 T C 30 1 31 8 32 6 35 8 40 4 31 4 32 9 34 2 39 1 43 8 32 7 33 9 35 7 42 4 47 3 S C 20 5 21 4 21 7 24 0 26 6 21 3 22 0 22 2 25 4 28 6 22 1 2...

Page 17: ...3 29 3 29 4 32 3 38 3 29 4 29 9 29 9 32 9 37 6 30 5 30 4 30 3 33 4 36 9 KW 4 58 4 60 4 60 4 65 4 72 4 67 4 68 4 68 4 73 4 79 4 76 4 77 4 76 4 82 4 85 115 T C 41 3 43 0 42 7 46 9 52 4 42 7 43 5 43 8 4...

Page 18: ...56 4 60 4 59 4 62 4 62 4 65 4 69 4 69 4 71 4 71 4 75 4 79 95 T C 51 3 53 9 54 8 60 2 65 5 53 3 55 3 55 8 61 1 66 9 55 3 56 6 56 7 61 9 68 2 S C 35 9 37 9 37 9 41 7 45 9 37 1 38 8 38 7 42 5 46 8 38 2...

Reviews: