17
Ducting version
In this case the fumes are conveyed outside of the building by means of a special
pipe connected with the connection ring located on top of the hood. Attention!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring. In the horizontal
runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to vent the
air easily from the room to the outside. Attention! If the hood is supplied with active charcoal
filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent to the air
outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution
of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct with an as smooth as possible inside.
!
The duct must be made of certified material.
Filter version
(draw. 24)
One active charcoal filter is needed for this and can be obtained from your usual
retailer.
The filter removes the grease and smells from the extracted air before sending it back into
the room through the upper outlet grid.
Installation
The minimum distance between the supporting surface for the cooking equipment on the
hob and the lowest part of the range hood must be not less than 50cm from electric cookers
and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be
adhered to.
Electrical connection
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket in
This hood must be installed on minimum 6"
round or rectangular equivalent ducting
Summary of Contents for LA 90 DOWNDRAFT BLK
Page 2: ...3 Front Front M6x10 4 szt ...
Page 3: ...4 4 1 2 3 This hood must be installed on minimum 6 round or rectangular equivalent ducting ...
Page 4: ...5 898 119 374 98 724 500 318 318 Ć150 ...
Page 5: ...6 ...
Page 6: ...7 885 110 ...
Page 7: ...8 ...
Page 8: ...9 ...
Page 9: ...10 M4x10 2x2 szt 3 9x9 5 2x4 szt ...
Page 10: ...11 M6x10 6 szt ...
Page 11: ...12 ...
Page 12: ...13 ...
Page 20: ......