9
rev.02 16-12-11
Instructions for use and maintenance
Base Lite
6.1
▪
Troubleshooting
ATTENTION
In case of faults or when troubleshooting, observe the safety regulations; in particular,
danger of lethal electrocution when troubleshooting or repairing electrical faults.
ELECTRICAL MAINTENANCE MAY ONLY BE PERFORMED BY QUALIFIED STAFF.
For any problems that are not indicated in the following table, please contact Technical Assistance.
MANUAL AWNING
PROBLEM
REASON
REMEDY
The fabric does not roll up straight Arms out of symmetry
Fabric thickness not uniform
Contact Technical Assistance
Fully rewind the fabric
POWERED AWNING
Without electronic power unit
PROBLEM
REASON
REMEDY
The fabric does not roll up straight Arms out of symmetry
Fabric thickness not uniform
Contact Technical Assistance
Fully rewind the fabric
The awning does not fully close
The awning does not fully open
Travel stop incorrectly adjusted
Motor gear moves
Contact Technical Assistance
Contact Technical Assistance
The motor is very noisy
Faulty wiring
Faulty motor
Contact Technical Assistance
Contact Technical Assistance
The motor stops after 4-5 minutes
of continuous use
Motor overheating protection tripped Let the motor cool down for a few
minutes
With electronic power unit
PROBLEM
REASON
REMEDY
The awning does not move
Fuse blown
Faulty wiring
Contact Technical Assistance
Contact Technical Assistance
The awning moves jerkily (it opens
for 50 cm and then stops, etc.).
Wind sensor faulty
Contact Technical Assistance
The awning does not close in strong
winds.
Fuse blown
Wind sensor faulty
Contact Technical Assistance
Contact Technical Assistance
The awning does not close during
heavy rain.
Fuse blown
Rain sensor faulty
Contact Technical Assistance
Contact Technical Assistance
With the remote control unit, the
awning opens or closes by itself.
Battery flat
Replace the batteries in the re-
mote control unit (see Control
instructions)