background image

3

© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

SETTING THE TIME AND DAY

To change 
current day.

Move the Speed Slide to SET DAY/TIME position. You should see the display pictured

above with a day of the week flashing. When you are finished setting the day and time,
rotate the dial to RUN to return to normal operation or to another position to continue
programming.

C

A

U

T

I

O

N

The TX250 is protected against normal static electric discharges.
However, in extremely dry weather you should touch another metal
object before the TX250 to avoid potential loss of programs.

To change the
current time.

To set current time. The (e.g.
“12:00”) will be flashing.

The TX250 alternately displays the

current time and the room 
temperature. It also displays the day of
the week and the currently active
program period that is controlling the temperature: MORN, DAY, EVE, or NITE.

The set point temperature will appear in the right side of the display. In the winter, set the

system switch to HEAT to control your heating system.  In the summer, set the switch to
COOL to control your air conditioner. In spring and fall or when windows are open, you can
set the system switch OFF.

Setting the FAN switch to AUTO

automatically runs your system’s fan
during heating and cooling. Setting
the FAN switch to ON runs your
system’s fan continuously even without heating or cooling. 

N

O

T

E

The FAN switch works only if your system 

provides a wire for the TX250’s “G” terminal.

• Press UP/DOWN to change the current temperature

setting. The OVERRIDE indicator appears on display.

• The OVERRIDE feature will be automatically canceled

at the start of the next program period.

• To cancel OVERRIDE prior to next program period press

UP/DOWN until original set temperature
appears. OVERRIDE indicator will disappear from display.

PROGRAMMING THE TX250

You can change any preset times and/or temperatures to suit your schedules for the

weekday and weekend programs. Each period (Morning, Day,
Evening, and Night) is programmed for HEAT and for COOL. 

HEAT

OFF

COOL

Select HEAT to program the 

TX250 for controlling your heater. 

To program temperature.

To change the start
time for MORN.

To move to DAY.

To change the temp. 
setting for MORN.

To program temperature.

To change start time 
for DAY.

To move to EVE.

To change the temp. 
setting for DAY.

To program temperature.

To change the start
time for EVE.

To move to NIGHT.

To change the temp.
setting for EVE.

To program temperature.

To change the start
time for NIGHT.

Move Speed Slide to RUN position to 

start the programs.

To change the temp.
setting for NIGHT.

Slide the Speed Slide to SET WEEKDAY PROGRAM. To program the weekends SET

WEEKEND. With Slide on SET WEEKDAY PROGRAM, you will see the display above.

TEMPORARY
TEMPERATURE OVERRIDE

TEMPERATURE OVERRIDE AND
TEMPERATURE HOLD 

MO

PM

MO

DAY

OVERRIDE

PM

H

E

A

T

MO TU WE TH FR

MORN

AM

H

E

A

T

DOWN

UP

These features let you change the current

Set Temperature without changing the programs
stored in your thermostat’s memory.

OR

Select COOL to program the

TX250 for controlling your air conditioner.

OPERATION

This thermostat is “armchair programmable”
You can make any program or setting
changes with the thermostat body off or on
the wall thermostat base.

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

NEXT

UP

UP

UP

DOWN

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

UP

DOWN

Push in the RESET key. This

sets the default heating and
cooling programs. To review the
default programs, move the Speed
Slide to SET WEEKDAY or
SET WEEKEND.

You can use the default 

programs as shown, or change
them as you wish. Each day is
divided into four periods. Each
period has its own starting time
and temperature.

THE BUILT-IN 

E

NERGY

S

TAR

®

PROGRAMS

PERIOD

HEAT

COOL

WEEKDAYS

MORN

6:00 AM 70°

6:00 AM 78°

preprograms

DAY

8:00 AM 62°

8:00 AM 85°

EVE

6:00 PM 70°

6:00 PM 78°

NIGHT

10:00 PM 62° 10:00 PM 82°

MORN

6:00 AM 70°

6:00 AM 78°

WEEKEND

DAY

8:00 AM 62°

8:00 AM 85°

preprograms

EVE

6:00 PM 70°

6:00 PM 78°

NIGHT

10:00 PM 62° 10:00 PM 82°

TEMPERATURE SWING

A thermostat works by turning your heating or cooling system on and off whenever the

room temperature varies a certain number of degrees from the set-point temperature. This
variation is the “swing.”

Your system should cycle on about 3 to 6 times per hour. A smaller swing number

increases the number of cycles, so room temperature is more constant. Setting “1” is
approximately 1/4°F. Each increase of 1 value increases the swing by approximately 1/4°F.
A larger swing number decreases the number of cycles, and may save energy in some
cases.

SWING SETTINGS

CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK

TECHNICAL SERVICE

If you have any problems installing or using this thermostat, please reread the instructions carefully.

Technical Service is available through our Technical Service Number. If you require assistance, please
call our offices between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday.
The number is (856) 234-8803 or visit our online technical support at www.luxproducts.com.

WARRANTY

Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of

date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover 
damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in
duration to one year from date of original purchase. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or
defective units to the participating retailer from which purchase was made, along with proof of
purchase. Please refer to Technical Service Section  before returning thermostat.

Purchaser assumes all risks and liability for incidental and consequential damage resulting from

installation and use of this unit. Some states do not allow the exclusion of incidental or consequential
damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state. Applicable in the U.S.A. only.

TEMPERATURE HOLD

MO

DAY

HOLD

PM

H

E

A

T

66

Speed Slide must
be in the run
position

Press together

ADVANCED FEATURES

SET TEMP SWING

To change 
swing

WARNING:

Making these changes will

require you to reset the thermostat. Copy
any of your customized programs onto
the chart below. This will be your
reference to reenter the programs
afterwards.
• Located to the left of the circuit board
are three black jumpers C/F and 24/12H.
• To change to Celsius - remove jumper
- JP2.
• To change to a 24HR clock - remove
jumper- JP1.
• Press the reset key on the front of the
thermostat for changes to take effect.

• Reprogram as necessary.

JP3

GAS

ELEC

JP2

JP1

JP3

JP2

JP1

2MIN

C

24HR

5MIN

F

12HR

OPEN CLOSE

Press to set.

• Press HOLD. Adjust temperature as 

desired with UP/DOWN.

• Temperature setting will not change even 

after next program period begins.

• To clear, press HOLD again.

HOLD

NEXT

NEXT

HOLD

UP

DOWN

5 MIN/ 2 MIN MINIMUM ON/OFF TIME

Your thermostat has an internal timer built in to protect your compressor. The timer forces

a minimum on/off time of 5 minutes. You may change this minimum on/off time to 2 minutes.
To accomplish this, remove the jumper labeled JP3. You must press the small reset
button on the face of the thermostat for the changes to take effect.

W

A

R

N

I

N

G

Making these changes will require you to reset the thermostat. Copy any of your customized

programs onto the blank chart. This will be your reference to re-enter the programs afterwards.

Reviews: