1. FEATURES

•  Extra Large Hybrid Touch Screen Display
•  Audible Touch Confirmation
•  EL Display Illumination
• Elegant Design
•  7 Day Programming
• Energy Star

®

Compliant

•  4 Periods Per Day
•  Battery Free Memory For All Programs And
Settings
• Temporary Temperature Override
• Temperature Hold
• Keyboard Lockout
•  F/C Temperature Display
•  12/24 Hr Clock Display
•  Adjustable Temperature Differential / Cycle Rate
• Temperature Calibration
•  5/2 minute selectable minimum Run/Off time
provides short cycle and compressor protection

CAUTION:
• The TX9000TS is protected against normal static

electric discharges. However, in extremely dry weather

you should touch a grounded metal object before the

TX9000TS to minimize the risk of causing damage to the

unit.
• Your thermostat is a precision instrument. Please

handle it with care.

2. COMPATIBILITY

The TX9000TS can be used with most 24 volt gas,
oil or electric heating and air conditioning systems,
single stage heat pumps or gas millivolt heating
systems. It cannot be used with 3 wire zone
valves, 120V systems, or multistage systems.

Ask your dealer for other LUX thermostats to
control those systems.

3. INSTALLATION

Please read all instructions carefully before
beginning installation.
WARNING:
• Your thermostat is a precision instrument. Please

handle it with care. 
•  All wiring must conform to local codes and

ordinances.
• Turn off electricity to the appliance before installing or

servicing thermostat or any part of the system. Do not

turn electricity back on until work is completed. 
• This thermostat is designed for use with 24 volt and

millivolt systems. The thermostat should be limited to a

maximum of 1.5 amps; higher amperage may cause

damage to the thermostat. 
• Do not short (jumper) across electric terminals at

control on furnace or air conditioner to test the system.

This will damage the thermostat and void your warranty.
3.1. TOOLS REQUIRED

#1 Phillips screwdriver (small)

Drill with 3/16-in. (4.8mm) bit

Wire stripper/cutter

3.2. LOCATION

On replacement installations, mount the new
thermostat in place of the old one unless the
conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.
• Locate the thermostat on an inside wall, about 5
ft. (1.5m) above the floor, in a room that is used
often.

2

TX9000TS

Summary of Contents for Smart Temp TXT9000TS Series

Page 1: ...SITIONING SWITCHES 8 7 6 GAS ELECTRIC JUMPER 8 8 BATTERIESANDMAINTENANCE 8 9 TECHNICALASSISTANCE 8 10 WARRANTY 8 SMART TEMP ELECTRONIC THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS Mt Laurel New Jersey 08054 USA www luxproducts com TX9000TS SERIES 52019 Choose Heat or Cool Set Day Time Installs Easily Easy as 1 2 3 Please read all instructions carefully before beginning installation Save them...

Page 2: ...sed with 3 wire zone valves 120V systems or multistage systems Ask your dealer for other LUX thermostats to control those systems 3 INSTALLATION Please read all instructions carefully before beginning installation WARNING Your thermostat is a precision instrument Please handle it with care All wiring must conform to local codes and ordinances Turn off electricity to the appliance before installing...

Page 3: ...ffecting the thermostat CAUTION Be careful not to drop the body or disturb electronic parts Leave the cover closed while the body is being removed from the base 7 Press up on the thumb latch at the bottom of thermostat and separate the body from its base 8 Hold the base against the wall Route the wires through the hole below the terminal block Position the base for best appearance to hide any mark...

Page 4: ...sed to adjust temperatures and change other settings 4 3 1 TEMPERATURE ADJUSTMENT Touch the displayed temperature once then touch the UP DOWN arrow key it adjusts the flashing set temperature by one degree in the associated direction Holding the key will automatically advance the setting in the associated direction For simple operation see HOLD 4 3 2 CHANGING OTHER SETTINGS If there are many choic...

Page 5: ...lashing OVERRIDE will be indicated at the top of the display OVERRIDE will be automatically canceled at the start of the next program period OVERRIDE will be cancelled if the set temperature is adjusted to its programmed value or if the units mode is changed 4 12 TEMPERATURE HOLD HOLD may be used for manual temperature control It is the simplest means to set and maintain a fixed temperature in Hea...

Page 6: ...Touch EXIT to return to main screen TIP Pressing Day Time or Temperature while programming will shift focus to that setting allowing it to be edited in the order most convenient for you 5 2 1 COPY COPY will copy the previous days programs into the current day and advance the thermostat to the beginning of next day 6 ADVANCED FEATURES 6 1 FILTER USAGE MONITOR The FILTER MONITOR is used to help dete...

Page 7: ...OWN arrows to count to code number Touch YES ENTER NEW CODE will appear Hold UP DOWN arrows to count to code number Record Code Number Touch YES to accept new code ENTER OLD CODE will be visible Touch EXIT to return to main display 6 5 2 TO LOCK SETTINGS Touch OPEN LOCK SYMBOL on display LOCK KEY will appear Touch YES The display will now show a CLOSED PADLOCK 6 5 3 TO UNLOCK SETTINGS Touch the CL...

Page 8: ...remove it from the wall 2 Remove the used batteries See battery location and polarity in figure on Page 12 3 Install two new Energizer or DURACELL AA size alkaline batteries in the battery compartment Observe the polarity marking shown in the compartment 4 Hang the top of the unit by the tabs at the top corners of the base then snap the bottom of the unit into place Do not use unnecessary force If...

Page 9: ...B G Y W W H 4 Y C 6 G F RH RC R V 5 B O C RH RC O B G Y W RH R V G F Y C 6 JUMPER PROVIDED JUMPER PROVIDED WIRING DIAGRAM NOTES APPLIES TO ALL DRAWINGS The DASHED lines are optional depending upon your system type Verify whether C X or B wires are connected to system common If B and O are both present it is likely that B is a system common If a B wire in your system is a common then connecting it ...

Page 10: ...R 120VAC AC COMPRESSOR FAN SYSTEMCOMMON OPTIONAL RC RH JUMPERPROVIDED WIRING DIAGRAM NOTES APPLIES TO ALL DRAWINGS The DASHED wires are optional depending on your system type Verify whether C X or B wires are connected to system common If B and O are both present it is likely that B is a system common If a B wire in your system is a common then connecting it to the B terminal may cause damage to y...

Page 11: ...C 5 WIRE SYSTEM HEATING AND COOLING 2 TRANSFORMERS 24VOLT HEAT TRANSFORMER 120VAC 24VOLT COOL TRANSFORMER 120VAC FAN COOLING HEAT OPTIONAL SYSTEMCOMMON RC RH JUMPERREMOVED W Y G B O RC RH C SINGLE STAGE HEAT PUMP SYSTEM 24VOLT SYSTEM TRANSFORMER 120VAC CHANGEOVER HEAT CHANGEOVER COOL B OR O BUTNEVERBOTH FAN HEAT PUMP ADD JUMPER SYSTEMCOMMON OPTIONAL RC RH JUMPERPROVIDED ...

Page 12: ...RN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT FRI SAT SUN PERIOD HEAT TIME TEMP TIME TEMP COOL 5 2 PROGRAMMING THE UNIT To ease reprogramming later record your thermostat s programs and settings in the table provided below GAS ELEC 1 2 3 4 ON 12hr 24hr 1 U4 SR OFF SR ON 2 F C 3 5min 2min 4 GAS ELECTRIC JUMPER OPTION SWITCHES C RH RC O B G Y W HARDWARE RESET OPTION SWITC...