25
save energy in some cases. There is only one Swing setting,
and this determines the cut-in and cut-out points for both
the first and second stages (if present), and affects both
heating and cooling. To change the Swing setting, ensure
that the System Mode switch is in the OFF position and the
rotary dial is in RUN. Press the HOLD button for at least 2
seconds. The words “SET:” and “SWING” will appear on the
screen with a single digit shown. Use the UP/DOWN buttons
to change the number value between 1 and 9 (0.25F to 2.25F,
in 0.25F degree increments). Number 1 is the default
setting. Press the NEXT button to accept the swing setting
and proceed to the OFFSET setting.
70˚F Set
Temperature
71
DEGREES (F)
** = Only applies if a second
heat stage is present
70
69
68
67
66
65
Swing
Setting=
#2
(+/- 0.5˚F)
Cut-In / Cut-Out
(1
st
Stage)
(2
nd
Stage) **
Cut-In / Cut-Out
Offset **
Setting=
4˚F degrees