![Lux Products PurePro Everything'Stat DP722 Installation And Operating Instructions Manual Download Page 6](http://html.mh-extra.com/html/lux-products/purepro-everythingstat-dp722/purepro-everythingstat-dp722_installation-and-operating-instructions-manual_1951500006.webp)
6
G O Y2 Y1 RC C RH W1 W2 E B
TYPICAL 24VAC 4 WIRE HOOKUP
SINGLE STAGE HEATING AND COOLING
FAN
XFMR
COMPRESSOR
GAS
VALVE
AC LINE
TYPICAL INSTALLER SETUP:
JUMPER
PROVIDED
SYSTEM COMMON
SYSTEM TYPE = FURNACE
[01]
HEAT STAGES =1
[02]
COMPRESSOR STAGES = 1
[03]
MODES = Ht-Off-Cl-Auto
[04]
HEAT FAN CONTROL
= GAS
[09]
OPTIONAL COMMON
ALLOWS USE OF
SYSTEM POWER
[1]
NOTES:
G O Y2 Y1 RC C RH W1 W2 E B
TYPICAL 5 WIRE HOOKUP
SINGLE STAGE HEATING AND COOLING
COOLING
XFMR 1
FAN
GAS
VALVE
HEATING
XFMR 2
AC LINE
AC LINE
COOL
COMMON
COMPRESSOR
TYPICAL INSTALLER SETUP:
SYSTEM TYPE = FURNACE
[01]
HEAT STAGES =1
[02]
COMPRESSOR STAGES = 1
[03]
MODES = Ht-Off-Cl-Auto
[04]
HEAT FAN CONTROL
= GAS
[09]
OPTIONAL COMMON
ALLOWS USE OF
SYSTEM POWER
[1]
NOTES: