ADVANCED SETTINGS - HUMIDITY SETTINGS
40
LUXPRO
®
PSPU732T
>>
Operating Tips
• HUMIDIFICATION FAN
should be set to
ON
when running steam or mist humidifiers.
• HUMIDIFICATION FAN
should be set to
OFF
when running drum humidifiers or any other humid-
ifier that requires the furnace to run in order to make humidity.
• DE-HUMIDIFICATION FAN
(DH) should be set to on when running separate de-humidification
equipment.
• DE-HUMIDIFICATION FAN
(DH) may be set to off when using the air conditioning as a means of
de-humidification. It may advantageous in some environments to turn the fan on independent-
ly when there is a call for DH in order to distribute the humidity level more evenly.
• DH REVERSE
function can be configured to meet the requirements of many variable speed fans,
consult the manual of your variable speed fan and determine if an “open” or “closed” contact
results in slowing fan operation.