I M P O R T A N T !

Please read all instructions carefully before beginning installation

and save for future reference. Before removing any wiring from

your existing thermostat, its wires must be labeled with their

terminal designations. Ignore the color of the wires since they

may not comply with any standard.

Thank you for your confidence in our product. To obtain the best results

from your investment, please read this manual and acquaint yourself with
your purchase before installing your new thermostat. Then follow the
installation procedures, one step at a time. This will save you time and
minimize the chance of damaging the thermostat and the systems it
controls. These instructions may contain information beyond that required
for your particular installation. Please save for future reference.

PSDH121 SERIES

HEAT

OFF

COOL

MO

Set Temperature

Choose Heat or Cool

Installs Easily

Easy as

1–2–3

Complete, Easy To Read

INSTALLATION AND OPERATING

INSTRUCTIONS

COMPATIBILITY

LUX PSDH121 was

designed for use with
single stage heat pump
systems with auxiliary
and/or emergency heat.
These systems are typical
known as 2-stage heat one
stage cool heat pump
systems.

FEATURES

Slim design may be vertically or

horizontally mounted

Large easy to read backlit display

Fan switch for system or 

continuous fan operation

Simple temperature Up or Down 

keys will display and adjust the 

Set Temperature.

Temperature displays in F° or C°

Temperature differential SWING 

settings of 0.25 and 0.5

Selectable 2 or 5-Minute 

Minimum Run/Off time provides 

short cycle and compressor 

protection

TEMP UP

MODE

FAN

MODE

TEMP DOWN

BACKLIGHT

RESET

WARNING:

Use Energizer

®

or DURACELL

®

Alkaline Batteries Only.

Energizer

®

is a registered trademark of Eveready Battery Company, Inc.

DURACELL

®

is a registered trademark of The Gillette Company, Inc.

52001

Patent # 6,951,306

In the winter, set the system switch to 

HEAT to control your heating 

system.

In the summer, set the switch to 

COOL to control your air conditioner.

Press either the 

TEMPERATURE UP or DOWN key in order to show 

the current 

SET TEMPERATURE.

Press 

TEMPERATURE UP or DOWN keys again until your desired 

temperature is displayed. The display will show the current room 
temperature again after two seconds.

Press the light bulb button to illuminate the display. Adjusting the 
temperature will keep the display lit until no button has been pressed 
for over ten seconds.

In spring and fall or when windows are open, you can set the system 
switch to 

OFF.

Setting the 

FAN switch to AUTO automatically runs your system’s fan 

during heating and cooling.

Setting the 

FAN switch to ON runs your system’s fan continuously even

without heating or cooling.

Setting the Mode switch to 

EMER (emergency heat) runs your 

Emergency heating system rather than the heat pump.

INSTALLATION

Please read all instructions carefully before beginning installation.

C A U T I O N

Turn off electricity to the appliance before installing or

servicing thermostat or any part of the system. Do not

turn electricity back on until work is completed.

● 

Do not short (jumper) across electric terminals at control on furnace or 

air conditioner to test the system. This will damage the thermostat and 
void your warranty.

● 

All wiring must conform to local codes and ordinances.

● 

This thermostat is designed for use with 24 volt and millivolt systems. 

The thermostat should be limited to a maximum of 1.5 amps; higher 
current may cause damage to the thermostat. If you are in doubt, call 
your HVAC contractor.

● 

Your thermostat is a precision instrument. Please handle it with care.

OFF

TOOLS REQUIRED

#1 Phillips screwdriver (small)

Drill with 3/16-in. (4.8mm) bit

Wire stripper/cutter

THERMOSTAT LOCATION

On replacement installations, mount the new thermostat in place of the

old one unless the conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.

Remember that your PSDH121 may be mounted vertically or 
horizontally when determining the optimal location.

Locate the thermostat on an inside wall, about 5 ft. (1.5m) above 
the floor, and in a room that is used often.

Do not install it where there are unusual heating conditions, such 
as: in direct sunlight; near a lamp, radio, television, radiator, 
register, or fireplace; near hot water pipes in a wall; near a stove 
on the other side of a wall.

Do not locate in unusual cooling conditions, such as: on a wall 
separating an unheated room; or in a draft from a stairwell, door, 
or window.

Do not locate in a damp area. This can lead to corrosion that will 
shorten thermostat life.

Do not locate where air circulation is poor, such as: in a corner 
or an alcove; or behind an open door.

Do not install the unit until all construction work and painting 
has been completed.