By default, this thermostat has 4 separate program periods for both Heat
and Cool mode, they are: MORN, DAY, EVE, and NITE. Each period ends
at the start time of the following period. The heat programs are set in
HEAT mode, and the cool programs are set in COOL mode.
NOTE: If the thermostat is configured to use only 2 periods per day
instead of 4 (HARDWARE SETUP OPTIONS), the thermostat will only use
the DAY and NITE periods. The MORN and EVE periods will not be visible
on the screen.
SET TEMPERATURE PROGRAMS:
Move the Set Slide switch to the TEMP
PROG position. Programming will start with all 5 weekdays, Monday
through Friday (all grouped together). Use the UP/DOWN buttons to
adjust the start time for the MORN period, then press the NEXT button to
advance. Use the UP/DOWN buttons to adjust the set temperature for the
MORN period, then press the NEXT button to advance. Now adjust the
start time and set temperature for the DAY period, pressing the NEXT
button after each to advance. Continue with these same steps to adjust
the start times and set temperatures for the EVE and NITE program
periods.
When the NITE period is finished for the weekdays, the thermostat will
advance forward to the weekend program, with the MORN period start
time flashing. You will be setting the program periods for both Saturday
and Sunday (grouped together). Perform the same steps that you used
for setting the weekday periods, pressing the NEXT button to advance
through each flashing value. Return the Set Slide switch to the RUN
position when you are finished.
24
TEMPERATURE PROGRAMS: