7. Programming the meter
The device allows the unit of measurement (liters, US gallons, US quarts, US pints, imperial gallons,
imperial quarts, imperial pints) to be selected, the basic selection of the medium characteristic curve
(watery media, thin mineral oils) to be performed, as well as a calibration to be performed to optimize
measurement accuracy.
7.1 Change over into programming mode
Hold down the "Mode" key until the program version is shown (e.g.
"P1.33") to switch to
programming mode
.
Once the key is released, a display test is carried out. Subsequently, multiple settings can be
configured in succession, beginning with the
selection of the unit of measurement for volume
. In
programming mode, the display will blink. If no key is pressed for more than 60 seconds, the device will
cancel programming mode and return to
dispensation mode
.
7.2 Setting the unit of measurement
The configured unit of measurement is shown and can be changed
if necessary. If the unit is changed, the partial volume shown as well
as all totalizers will automatically be converted.
"Reset" key:
Toggles between the units liters (L), US gallons
(US GAL), US quarts (US QTS), US pints (US PTS),
imperial gallons (IMP GAL), imperial quarts (IMP
QTS) and imperial pints (IMP PTS).
"Mode" key: Confirms the volume unit shown and switches to
meter type selection
.